241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL

The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the followin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection dosimetry 2018-08, Vol.180 (1-4), p.29-32
Hauptverfasser: Pereira, W W, Estrada, J J S, Patrão, K C S, Alves, C F E, Magalhães, L A G, Leite, S P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 32
container_issue 1-4
container_start_page 29
container_title Radiation protection dosimetry
container_volume 180
creator Pereira, W W
Estrada, J J S
Patrão, K C S
Alves, C F E
Magalhães, L A G
Leite, S P
description The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the following attributes: neutron energy distribution, anisotropy and emission rate. In order to make these values into high-level metrological references traceable by the Bureau International des Poids et Mesures, these measurements were taken at the Neutron Laboratory part of the Laboratório Nacional de Metrologia das Radiações Ionizantes. Results obtained for the source spectrum have strong adherence to the reference spectrum established by ISO 8529-1. The new laboratory for neutron calibration will allow calibration in an approximate ambient dose equivalent ranging 20-4500 μSv/h.
doi_str_mv 10.1093/rpd/ncx238
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1964696941</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1964696941</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1325-6aefd3df5c195e909a50257dad038397b1344fbfcb7cc63a7ed968d0e96463083</originalsourceid><addsrcrecordid>eNo90MtKw0AAheFBFFurGx9AZlnF2Lkns5yGXgKhgRCRdjMkMxOoNG3NtKCP5Yv4TLa0ujqbj7P4AbjH6AUjSQft1g7W5pPQ6AJ0cchIQBkSl6CLMGNBxAjqgBvv3xEioeTsGnSIxFQQyrtgQhhWTTB0_Z_v5_UjjKcqV3ExypOFKpJsBsdZDhWcjd5gqoZZroosn8OxipM0KeYwmcFhrhZJeguu6nLl3d15e-B1PCriaZBmkyRWaWAwJTwQpasttTU3WHInkSw5Ijy0pUU0ojKsMGWsrmpThcYIWobOShFZ5KRggqKI9kD_9LttNx9753e6WXrjVqty7TZ7r_ERSiEZPtCnEzXtxvvW1XrbLpuy_dIY6WM4fQinT-EO-OH8u68aZ__pXyn6C8JHYz4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1964696941</pqid></control><display><type>article</type><title>241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Alma/SFX Local Collection</source><creator>Pereira, W W ; Estrada, J J S ; Patrão, K C S ; Alves, C F E ; Magalhães, L A G ; Leite, S P</creator><creatorcontrib>Pereira, W W ; Estrada, J J S ; Patrão, K C S ; Alves, C F E ; Magalhães, L A G ; Leite, S P</creatorcontrib><description>The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the following attributes: neutron energy distribution, anisotropy and emission rate. In order to make these values into high-level metrological references traceable by the Bureau International des Poids et Mesures, these measurements were taken at the Neutron Laboratory part of the Laboratório Nacional de Metrologia das Radiações Ionizantes. Results obtained for the source spectrum have strong adherence to the reference spectrum established by ISO 8529-1. The new laboratory for neutron calibration will allow calibration in an approximate ambient dose equivalent ranging 20-4500 μSv/h.</description><identifier>ISSN: 0144-8420</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncx238</identifier><identifier>PMID: 29136235</identifier><language>eng</language><publisher>England</publisher><subject>Alpha Particles ; Americium - analysis ; Americium - standards ; Laboratories - standards ; Radiation Dosage ; Radiation Monitoring - standards ; Radiation Protection - standards</subject><ispartof>Radiation protection dosimetry, 2018-08, Vol.180 (1-4), p.29-32</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1325-6aefd3df5c195e909a50257dad038397b1344fbfcb7cc63a7ed968d0e96463083</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29136235$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pereira, W W</creatorcontrib><creatorcontrib>Estrada, J J S</creatorcontrib><creatorcontrib>Patrão, K C S</creatorcontrib><creatorcontrib>Alves, C F E</creatorcontrib><creatorcontrib>Magalhães, L A G</creatorcontrib><creatorcontrib>Leite, S P</creatorcontrib><title>241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the following attributes: neutron energy distribution, anisotropy and emission rate. In order to make these values into high-level metrological references traceable by the Bureau International des Poids et Mesures, these measurements were taken at the Neutron Laboratory part of the Laboratório Nacional de Metrologia das Radiações Ionizantes. Results obtained for the source spectrum have strong adherence to the reference spectrum established by ISO 8529-1. The new laboratory for neutron calibration will allow calibration in an approximate ambient dose equivalent ranging 20-4500 μSv/h.</description><subject>Alpha Particles</subject><subject>Americium - analysis</subject><subject>Americium - standards</subject><subject>Laboratories - standards</subject><subject>Radiation Dosage</subject><subject>Radiation Monitoring - standards</subject><subject>Radiation Protection - standards</subject><issn>0144-8420</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo90MtKw0AAheFBFFurGx9AZlnF2Lkns5yGXgKhgRCRdjMkMxOoNG3NtKCP5Yv4TLa0ujqbj7P4AbjH6AUjSQft1g7W5pPQ6AJ0cchIQBkSl6CLMGNBxAjqgBvv3xEioeTsGnSIxFQQyrtgQhhWTTB0_Z_v5_UjjKcqV3ExypOFKpJsBsdZDhWcjd5gqoZZroosn8OxipM0KeYwmcFhrhZJeguu6nLl3d15e-B1PCriaZBmkyRWaWAwJTwQpasttTU3WHInkSw5Ijy0pUU0ojKsMGWsrmpThcYIWobOShFZ5KRggqKI9kD_9LttNx9753e6WXrjVqty7TZ7r_ERSiEZPtCnEzXtxvvW1XrbLpuy_dIY6WM4fQinT-EO-OH8u68aZ__pXyn6C8JHYz4</recordid><startdate>20180801</startdate><enddate>20180801</enddate><creator>Pereira, W W</creator><creator>Estrada, J J S</creator><creator>Patrão, K C S</creator><creator>Alves, C F E</creator><creator>Magalhães, L A G</creator><creator>Leite, S P</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20180801</creationdate><title>241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL</title><author>Pereira, W W ; Estrada, J J S ; Patrão, K C S ; Alves, C F E ; Magalhães, L A G ; Leite, S P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1325-6aefd3df5c195e909a50257dad038397b1344fbfcb7cc63a7ed968d0e96463083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Alpha Particles</topic><topic>Americium - analysis</topic><topic>Americium - standards</topic><topic>Laboratories - standards</topic><topic>Radiation Dosage</topic><topic>Radiation Monitoring - standards</topic><topic>Radiation Protection - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pereira, W W</creatorcontrib><creatorcontrib>Estrada, J J S</creatorcontrib><creatorcontrib>Patrão, K C S</creatorcontrib><creatorcontrib>Alves, C F E</creatorcontrib><creatorcontrib>Magalhães, L A G</creatorcontrib><creatorcontrib>Leite, S P</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pereira, W W</au><au>Estrada, J J S</au><au>Patrão, K C S</au><au>Alves, C F E</au><au>Magalhães, L A G</au><au>Leite, S P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2018-08-01</date><risdate>2018</risdate><volume>180</volume><issue>1-4</issue><spage>29</spage><epage>32</epage><pages>29-32</pages><issn>0144-8420</issn><eissn>1742-3406</eissn><abstract>The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the following attributes: neutron energy distribution, anisotropy and emission rate. In order to make these values into high-level metrological references traceable by the Bureau International des Poids et Mesures, these measurements were taken at the Neutron Laboratory part of the Laboratório Nacional de Metrologia das Radiações Ionizantes. Results obtained for the source spectrum have strong adherence to the reference spectrum established by ISO 8529-1. The new laboratory for neutron calibration will allow calibration in an approximate ambient dose equivalent ranging 20-4500 μSv/h.</abstract><cop>England</cop><pmid>29136235</pmid><doi>10.1093/rpd/ncx238</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0144-8420
ispartof Radiation protection dosimetry, 2018-08, Vol.180 (1-4), p.29-32
issn 0144-8420
1742-3406
language eng
recordid cdi_proquest_miscellaneous_1964696941
source MEDLINE; Oxford University Press Journals All Titles (1996-Current); Alma/SFX Local Collection
subjects Alpha Particles
Americium - analysis
Americium - standards
Laboratories - standards
Radiation Dosage
Radiation Monitoring - standards
Radiation Protection - standards
title 241Am-Be(α,n) CHARACTERIZATION FOR A NEW LABORATORY FACILITY IN BRAZIL
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T17%3A55%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=241Am-Be(%CE%B1,n)%20CHARACTERIZATION%20FOR%20A%20NEW%20LABORATORY%20FACILITY%20IN%20BRAZIL&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Pereira,%20W%20W&rft.date=2018-08-01&rft.volume=180&rft.issue=1-4&rft.spage=29&rft.epage=32&rft.pages=29-32&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncx238&rft_dat=%3Cproquest_cross%3E1964696941%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1964696941&rft_id=info:pmid/29136235&rfr_iscdi=true