The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance

The permeability of a powder bed reflects its particle size distribution, shape, packing, porosity, cohesivity, and tensile strength in a manner relevant to powder fluidization. The relationship between the permeability and the performance of carrier-based dry powder inhalation (DPI) mixtures has, h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AAPS PharmSciTech 2018-02, Vol.19 (2), p.912-922
Hauptverfasser: Shalash, Ahmed O., Khalafallah, Nawal M., Molokhia, Abdulla M., Elsayed, Mustafa M. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 922
container_issue 2
container_start_page 912
container_title AAPS PharmSciTech
container_volume 19
creator Shalash, Ahmed O.
Khalafallah, Nawal M.
Molokhia, Abdulla M.
Elsayed, Mustafa M. A.
description The permeability of a powder bed reflects its particle size distribution, shape, packing, porosity, cohesivity, and tensile strength in a manner relevant to powder fluidization. The relationship between the permeability and the performance of carrier-based dry powder inhalation (DPI) mixtures has, however, aroused controversy. The current study sought to gain new insights into the relationship and to explore its potential applications. We studied eight lactose materials as DPI carriers. The carriers covered a broad permeability range of 0.42–13.53 D and moreover differed in particle size distribution, particle shape, crystal form, and/or porosity. We evaluated the performance of inhalation mixtures of each of these carriers and fluticasone propionate after aerosolization from an Aerolizer®, a model turbulent-shear inhaler, at a flow rate of 60 L/min. Starting from the high permeability side, the inhalation mixture performance increased as the carrier permeability decreased until optimum performance was reached at permeability of ~ 3.2 D. Increased resistance to air flow strengthens aerodynamic dispersion forces. The inhalation mixture performance then decreased as the carrier permeability further decreased. Very high resistance to air flow restricts powder dispersion. The permeability accounted for effects of carrier size, shape, and macroporosity on the performance. We confirmed the relationship by analysis of two literature permeability–performance datasets, representing measurements that differ from ours in terms of carrier grades, drug, technique used to determine permeability, turbulent-shear inhaler, and/or aerosolization flow rate. Permeability provides useful information that can aid development of DPI mixtures for turbulent-shear inhalers. A practical guidance is provided.
doi_str_mv 10.1208/s12249-017-0898-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1955072997</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1955072997</sourcerecordid><originalsourceid>FETCH-LOGICAL-c344t-620aed252a9240d1ef492b290e7728662dca67a03a7365cd3484884e195bb5ce3</originalsourceid><addsrcrecordid>eNp9kctu1DAUhi1ERUvhAdggL9mk-JLEMTs6paVSCyNU1taJfdJxlctgOxrmNXhiPKRFrFjZ8v-dTzr-CXnD2RkXrHkfuRClLhhXBWt0U6hn5IRXkhVaS_H8n_sxeRnjA2NCci1fkGOhWS2lUifk190G6TfsIflpjBu_peeYdogjTTlYYxgQWt_7tKcwuqfHbgoDjBbp1NEVhOAxFOcQ0dGLsKfraecw0OtxA4uX3vqfaQ4YP9AvuMtB9PebFP8Y1wFs8hZ6ejV7d5C-Ikcd9BFfP56n5Pvlp7vV5-Lm69X16uNNYWVZpqIWDNCJSoAWJXMcu1KLNm-GSommroWzUCtgEpSsK-tk2ZRNUyLXVdtWFuUpebd4t2H6MWNMZvDRYt_DiNMcTQYrpoTWKqN8QW2YYgzYmW3wA4S94cwcqjBLFSZXYQ5VmMPM20f93A7o_k48_X0GxALEHI33GMzDNIcxr_wf628qXZVM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1955072997</pqid></control><display><type>article</type><title>The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance</title><source>Springer Nature - Complete Springer Journals</source><creator>Shalash, Ahmed O. ; Khalafallah, Nawal M. ; Molokhia, Abdulla M. ; Elsayed, Mustafa M. A.</creator><creatorcontrib>Shalash, Ahmed O. ; Khalafallah, Nawal M. ; Molokhia, Abdulla M. ; Elsayed, Mustafa M. A.</creatorcontrib><description>The permeability of a powder bed reflects its particle size distribution, shape, packing, porosity, cohesivity, and tensile strength in a manner relevant to powder fluidization. The relationship between the permeability and the performance of carrier-based dry powder inhalation (DPI) mixtures has, however, aroused controversy. The current study sought to gain new insights into the relationship and to explore its potential applications. We studied eight lactose materials as DPI carriers. The carriers covered a broad permeability range of 0.42–13.53 D and moreover differed in particle size distribution, particle shape, crystal form, and/or porosity. We evaluated the performance of inhalation mixtures of each of these carriers and fluticasone propionate after aerosolization from an Aerolizer®, a model turbulent-shear inhaler, at a flow rate of 60 L/min. Starting from the high permeability side, the inhalation mixture performance increased as the carrier permeability decreased until optimum performance was reached at permeability of ~ 3.2 D. Increased resistance to air flow strengthens aerodynamic dispersion forces. The inhalation mixture performance then decreased as the carrier permeability further decreased. Very high resistance to air flow restricts powder dispersion. The permeability accounted for effects of carrier size, shape, and macroporosity on the performance. We confirmed the relationship by analysis of two literature permeability–performance datasets, representing measurements that differ from ours in terms of carrier grades, drug, technique used to determine permeability, turbulent-shear inhaler, and/or aerosolization flow rate. Permeability provides useful information that can aid development of DPI mixtures for turbulent-shear inhalers. A practical guidance is provided.</description><identifier>ISSN: 1530-9932</identifier><identifier>EISSN: 1530-9932</identifier><identifier>DOI: 10.1208/s12249-017-0898-7</identifier><identifier>PMID: 29063377</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Biochemistry ; Biomedical and Life Sciences ; Biomedicine ; Biotechnology ; Pharmacology/Toxicology ; Pharmacy ; Research Article</subject><ispartof>AAPS PharmSciTech, 2018-02, Vol.19 (2), p.912-922</ispartof><rights>American Association of Pharmaceutical Scientists 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c344t-620aed252a9240d1ef492b290e7728662dca67a03a7365cd3484884e195bb5ce3</citedby><cites>FETCH-LOGICAL-c344t-620aed252a9240d1ef492b290e7728662dca67a03a7365cd3484884e195bb5ce3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1208/s12249-017-0898-7$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1208/s12249-017-0898-7$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,778,782,27907,27908,41471,42540,51302</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29063377$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shalash, Ahmed O.</creatorcontrib><creatorcontrib>Khalafallah, Nawal M.</creatorcontrib><creatorcontrib>Molokhia, Abdulla M.</creatorcontrib><creatorcontrib>Elsayed, Mustafa M. A.</creatorcontrib><title>The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance</title><title>AAPS PharmSciTech</title><addtitle>AAPS PharmSciTech</addtitle><addtitle>AAPS PharmSciTech</addtitle><description>The permeability of a powder bed reflects its particle size distribution, shape, packing, porosity, cohesivity, and tensile strength in a manner relevant to powder fluidization. The relationship between the permeability and the performance of carrier-based dry powder inhalation (DPI) mixtures has, however, aroused controversy. The current study sought to gain new insights into the relationship and to explore its potential applications. We studied eight lactose materials as DPI carriers. The carriers covered a broad permeability range of 0.42–13.53 D and moreover differed in particle size distribution, particle shape, crystal form, and/or porosity. We evaluated the performance of inhalation mixtures of each of these carriers and fluticasone propionate after aerosolization from an Aerolizer®, a model turbulent-shear inhaler, at a flow rate of 60 L/min. Starting from the high permeability side, the inhalation mixture performance increased as the carrier permeability decreased until optimum performance was reached at permeability of ~ 3.2 D. Increased resistance to air flow strengthens aerodynamic dispersion forces. The inhalation mixture performance then decreased as the carrier permeability further decreased. Very high resistance to air flow restricts powder dispersion. The permeability accounted for effects of carrier size, shape, and macroporosity on the performance. We confirmed the relationship by analysis of two literature permeability–performance datasets, representing measurements that differ from ours in terms of carrier grades, drug, technique used to determine permeability, turbulent-shear inhaler, and/or aerosolization flow rate. Permeability provides useful information that can aid development of DPI mixtures for turbulent-shear inhalers. A practical guidance is provided.</description><subject>Biochemistry</subject><subject>Biomedical and Life Sciences</subject><subject>Biomedicine</subject><subject>Biotechnology</subject><subject>Pharmacology/Toxicology</subject><subject>Pharmacy</subject><subject>Research Article</subject><issn>1530-9932</issn><issn>1530-9932</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kctu1DAUhi1ERUvhAdggL9mk-JLEMTs6paVSCyNU1taJfdJxlctgOxrmNXhiPKRFrFjZ8v-dTzr-CXnD2RkXrHkfuRClLhhXBWt0U6hn5IRXkhVaS_H8n_sxeRnjA2NCci1fkGOhWS2lUifk190G6TfsIflpjBu_peeYdogjTTlYYxgQWt_7tKcwuqfHbgoDjBbp1NEVhOAxFOcQ0dGLsKfraecw0OtxA4uX3vqfaQ4YP9AvuMtB9PebFP8Y1wFs8hZ6ejV7d5C-Ikcd9BFfP56n5Pvlp7vV5-Lm69X16uNNYWVZpqIWDNCJSoAWJXMcu1KLNm-GSommroWzUCtgEpSsK-tk2ZRNUyLXVdtWFuUpebd4t2H6MWNMZvDRYt_DiNMcTQYrpoTWKqN8QW2YYgzYmW3wA4S94cwcqjBLFSZXYQ5VmMPM20f93A7o_k48_X0GxALEHI33GMzDNIcxr_wf628qXZVM</recordid><startdate>20180201</startdate><enddate>20180201</enddate><creator>Shalash, Ahmed O.</creator><creator>Khalafallah, Nawal M.</creator><creator>Molokhia, Abdulla M.</creator><creator>Elsayed, Mustafa M. A.</creator><general>Springer US</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20180201</creationdate><title>The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance</title><author>Shalash, Ahmed O. ; Khalafallah, Nawal M. ; Molokhia, Abdulla M. ; Elsayed, Mustafa M. A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c344t-620aed252a9240d1ef492b290e7728662dca67a03a7365cd3484884e195bb5ce3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Biochemistry</topic><topic>Biomedical and Life Sciences</topic><topic>Biomedicine</topic><topic>Biotechnology</topic><topic>Pharmacology/Toxicology</topic><topic>Pharmacy</topic><topic>Research Article</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shalash, Ahmed O.</creatorcontrib><creatorcontrib>Khalafallah, Nawal M.</creatorcontrib><creatorcontrib>Molokhia, Abdulla M.</creatorcontrib><creatorcontrib>Elsayed, Mustafa M. A.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>AAPS PharmSciTech</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shalash, Ahmed O.</au><au>Khalafallah, Nawal M.</au><au>Molokhia, Abdulla M.</au><au>Elsayed, Mustafa M. A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance</atitle><jtitle>AAPS PharmSciTech</jtitle><stitle>AAPS PharmSciTech</stitle><addtitle>AAPS PharmSciTech</addtitle><date>2018-02-01</date><risdate>2018</risdate><volume>19</volume><issue>2</issue><spage>912</spage><epage>922</epage><pages>912-922</pages><issn>1530-9932</issn><eissn>1530-9932</eissn><abstract>The permeability of a powder bed reflects its particle size distribution, shape, packing, porosity, cohesivity, and tensile strength in a manner relevant to powder fluidization. The relationship between the permeability and the performance of carrier-based dry powder inhalation (DPI) mixtures has, however, aroused controversy. The current study sought to gain new insights into the relationship and to explore its potential applications. We studied eight lactose materials as DPI carriers. The carriers covered a broad permeability range of 0.42–13.53 D and moreover differed in particle size distribution, particle shape, crystal form, and/or porosity. We evaluated the performance of inhalation mixtures of each of these carriers and fluticasone propionate after aerosolization from an Aerolizer®, a model turbulent-shear inhaler, at a flow rate of 60 L/min. Starting from the high permeability side, the inhalation mixture performance increased as the carrier permeability decreased until optimum performance was reached at permeability of ~ 3.2 D. Increased resistance to air flow strengthens aerodynamic dispersion forces. The inhalation mixture performance then decreased as the carrier permeability further decreased. Very high resistance to air flow restricts powder dispersion. The permeability accounted for effects of carrier size, shape, and macroporosity on the performance. We confirmed the relationship by analysis of two literature permeability–performance datasets, representing measurements that differ from ours in terms of carrier grades, drug, technique used to determine permeability, turbulent-shear inhaler, and/or aerosolization flow rate. Permeability provides useful information that can aid development of DPI mixtures for turbulent-shear inhalers. A practical guidance is provided.</abstract><cop>New York</cop><pub>Springer US</pub><pmid>29063377</pmid><doi>10.1208/s12249-017-0898-7</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1530-9932
ispartof AAPS PharmSciTech, 2018-02, Vol.19 (2), p.912-922
issn 1530-9932
1530-9932
language eng
recordid cdi_proquest_miscellaneous_1955072997
source Springer Nature - Complete Springer Journals
subjects Biochemistry
Biomedical and Life Sciences
Biomedicine
Biotechnology
Pharmacology/Toxicology
Pharmacy
Research Article
title The Relationship Between the Permeability and the Performance of Carrier-Based Dry Powder Inhalation Mixtures: New Insights and Practical Guidance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T11%3A00%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Relationship%20Between%20the%20Permeability%20and%20the%20Performance%20of%20Carrier-Based%20Dry%20Powder%20Inhalation%20Mixtures:%20New%20Insights%20and%20Practical%20Guidance&rft.jtitle=AAPS%20PharmSciTech&rft.au=Shalash,%20Ahmed%20O.&rft.date=2018-02-01&rft.volume=19&rft.issue=2&rft.spage=912&rft.epage=922&rft.pages=912-922&rft.issn=1530-9932&rft.eissn=1530-9932&rft_id=info:doi/10.1208/s12249-017-0898-7&rft_dat=%3Cproquest_cross%3E1955072997%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1955072997&rft_id=info:pmid/29063377&rfr_iscdi=true