Prospects of Contrast‐Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta‐analysis

Objectives Contrast‐enhanced ultrasonography (CEUS) is a modern diagnostic method that can also be used to study microperfusion. This study compared the time to peak intensity measured by CEUS in patients with peripheral arterial disease (PAD) and healthy control participants. Methods After a compre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of ultrasound in medicine 2018-05, Vol.37 (5), p.1081-1090
Hauptverfasser: Hou, Xiao‐xia, Chu, Guang‐hua, Yu, Yuan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1090
container_issue 5
container_start_page 1081
container_title Journal of ultrasound in medicine
container_volume 37
creator Hou, Xiao‐xia
Chu, Guang‐hua
Yu, Yuan
description Objectives Contrast‐enhanced ultrasonography (CEUS) is a modern diagnostic method that can also be used to study microperfusion. This study compared the time to peak intensity measured by CEUS in patients with peripheral arterial disease (PAD) and healthy control participants. Methods After a comprehensive literature search in multiple electronic databases and study selection, a random‐effect meta‐analysis was performed to compare the time to peak intensity measured by CEUS in patients with PAD and healthy controls, which followed meta‐regression analyses for identification of factors affecting the outcomes. Results Fourteen studies (data for 322 patients with PAD and 314 healthy individuals) were used for the meta‐analysis. The age of this sample of patients with PAD was 64.92 (95% confidence interval, 62.53, 67.31) years, and that of the healthy controls was 55.32 (51.67, 58.98) years. The times to peak intensity were 18.55 (15.62, 21.48) seconds in healthy controls, 33.40 (27.65, 39.15) seconds in patients with PAD, and 76.22 (36.23, 116.22) seconds in patients with PAD and diabetes mellitus. The difference between patients with PAD and healthy controls in the time to peak intensity was statistically significant (mean difference, 24.80 [10.16, 39.44] seconds; P 
doi_str_mv 10.1002/jum.14451
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1955067811</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1955067811</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3911-ef2259d4ca7106b39d36b4dedeef347f0b03fb761435c19a47ca5dd493e71feb3</originalsourceid><addsrcrecordid>eNp1kLtOwzAUQC0EgvIY-AHkEYYU39iJMVvVlpeKYKBz5CTXNCiNg50KdeMT-Ea-BPcBG9P1tc49wyHkFFgfGIsv3xbzPgiRwA7pQZKwSKXAd0mPxfIqErGSB-TQ-7eAMpBinxzEiqUCYtYj3bOzvsWi89QaOrRN57Tvvj-_xs1MNwWWdFqvvmxjX51uZ0tqrKPdDOmo0q-N9dX68Bld1c7Q6ZoOXBeW8BhVHrXHazqgj9jp4NSNrpfh4pjsGV17PNnOIzK9Gb8M76LJ0-39cDCJCq4AIjRxnKhSFFoCS3OuSp7mosQS0XAhDcsZN7lMQfCkAKWFLHRSlkJxlGAw50fkfONtnX1foO-yeeULrGvdoF34DFSIlcorgIBebNAi9PAOTda6aq7dMgOWrSJnIXK2jhzYs612kc-x_CN_qwbgcgN8VDUu_zdlD9PHjfIHt0mJ6A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1955067811</pqid></control><display><type>article</type><title>Prospects of Contrast‐Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta‐analysis</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Hou, Xiao‐xia ; Chu, Guang‐hua ; Yu, Yuan</creator><creatorcontrib>Hou, Xiao‐xia ; Chu, Guang‐hua ; Yu, Yuan</creatorcontrib><description>Objectives Contrast‐enhanced ultrasonography (CEUS) is a modern diagnostic method that can also be used to study microperfusion. This study compared the time to peak intensity measured by CEUS in patients with peripheral arterial disease (PAD) and healthy control participants. Methods After a comprehensive literature search in multiple electronic databases and study selection, a random‐effect meta‐analysis was performed to compare the time to peak intensity measured by CEUS in patients with PAD and healthy controls, which followed meta‐regression analyses for identification of factors affecting the outcomes. Results Fourteen studies (data for 322 patients with PAD and 314 healthy individuals) were used for the meta‐analysis. The age of this sample of patients with PAD was 64.92 (95% confidence interval, 62.53, 67.31) years, and that of the healthy controls was 55.32 (51.67, 58.98) years. The times to peak intensity were 18.55 (15.62, 21.48) seconds in healthy controls, 33.40 (27.65, 39.15) seconds in patients with PAD, and 76.22 (36.23, 116.22) seconds in patients with PAD and diabetes mellitus. The difference between patients with PAD and healthy controls in the time to peak intensity was statistically significant (mean difference, 24.80 [10.16, 39.44] seconds; P &lt; .00009). The ABI was not significantly associated with the time to peak intensity in patients with PAD. Age and sex were also not significantly associated with the time to peak intensity. Conclusions Contrast‐enhanced ultrasonography is a valuable tool for the diagnosis of PAD based on its ability to differentiate the time to peak intensity between patients with PAD and healthy individuals, but little data are yet available to assess its diagnostic ability in clinical practice.</description><identifier>ISSN: 0278-4297</identifier><identifier>EISSN: 1550-9613</identifier><identifier>DOI: 10.1002/jum.14451</identifier><identifier>PMID: 29064120</identifier><language>eng</language><publisher>England</publisher><subject>angiopathy ; atherosclerosis ; Contrast Media ; contrast‐enhanced ultrasonography ; diagnosis ; Humans ; Image Enhancement - methods ; peripheral arterial disease ; Peripheral Arterial Disease - diagnostic imaging ; peripheral vascular ; statistics ; therapeutic ; Ultrasonography - methods</subject><ispartof>Journal of ultrasound in medicine, 2018-05, Vol.37 (5), p.1081-1090</ispartof><rights>2017 by the American Institute of Ultrasound in Medicine</rights><rights>2017 by the American Institute of Ultrasound in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3911-ef2259d4ca7106b39d36b4dedeef347f0b03fb761435c19a47ca5dd493e71feb3</citedby><cites>FETCH-LOGICAL-c3911-ef2259d4ca7106b39d36b4dedeef347f0b03fb761435c19a47ca5dd493e71feb3</cites><orcidid>0000-0001-8082-5982</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjum.14451$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjum.14451$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29064120$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hou, Xiao‐xia</creatorcontrib><creatorcontrib>Chu, Guang‐hua</creatorcontrib><creatorcontrib>Yu, Yuan</creatorcontrib><title>Prospects of Contrast‐Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta‐analysis</title><title>Journal of ultrasound in medicine</title><addtitle>J Ultrasound Med</addtitle><description>Objectives Contrast‐enhanced ultrasonography (CEUS) is a modern diagnostic method that can also be used to study microperfusion. This study compared the time to peak intensity measured by CEUS in patients with peripheral arterial disease (PAD) and healthy control participants. Methods After a comprehensive literature search in multiple electronic databases and study selection, a random‐effect meta‐analysis was performed to compare the time to peak intensity measured by CEUS in patients with PAD and healthy controls, which followed meta‐regression analyses for identification of factors affecting the outcomes. Results Fourteen studies (data for 322 patients with PAD and 314 healthy individuals) were used for the meta‐analysis. The age of this sample of patients with PAD was 64.92 (95% confidence interval, 62.53, 67.31) years, and that of the healthy controls was 55.32 (51.67, 58.98) years. The times to peak intensity were 18.55 (15.62, 21.48) seconds in healthy controls, 33.40 (27.65, 39.15) seconds in patients with PAD, and 76.22 (36.23, 116.22) seconds in patients with PAD and diabetes mellitus. The difference between patients with PAD and healthy controls in the time to peak intensity was statistically significant (mean difference, 24.80 [10.16, 39.44] seconds; P &lt; .00009). The ABI was not significantly associated with the time to peak intensity in patients with PAD. Age and sex were also not significantly associated with the time to peak intensity. Conclusions Contrast‐enhanced ultrasonography is a valuable tool for the diagnosis of PAD based on its ability to differentiate the time to peak intensity between patients with PAD and healthy individuals, but little data are yet available to assess its diagnostic ability in clinical practice.</description><subject>angiopathy</subject><subject>atherosclerosis</subject><subject>Contrast Media</subject><subject>contrast‐enhanced ultrasonography</subject><subject>diagnosis</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>peripheral arterial disease</subject><subject>Peripheral Arterial Disease - diagnostic imaging</subject><subject>peripheral vascular</subject><subject>statistics</subject><subject>therapeutic</subject><subject>Ultrasonography - methods</subject><issn>0278-4297</issn><issn>1550-9613</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kLtOwzAUQC0EgvIY-AHkEYYU39iJMVvVlpeKYKBz5CTXNCiNg50KdeMT-Ea-BPcBG9P1tc49wyHkFFgfGIsv3xbzPgiRwA7pQZKwSKXAd0mPxfIqErGSB-TQ-7eAMpBinxzEiqUCYtYj3bOzvsWi89QaOrRN57Tvvj-_xs1MNwWWdFqvvmxjX51uZ0tqrKPdDOmo0q-N9dX68Bld1c7Q6ZoOXBeW8BhVHrXHazqgj9jp4NSNrpfh4pjsGV17PNnOIzK9Gb8M76LJ0-39cDCJCq4AIjRxnKhSFFoCS3OuSp7mosQS0XAhDcsZN7lMQfCkAKWFLHRSlkJxlGAw50fkfONtnX1foO-yeeULrGvdoF34DFSIlcorgIBebNAi9PAOTda6aq7dMgOWrSJnIXK2jhzYs612kc-x_CN_qwbgcgN8VDUu_zdlD9PHjfIHt0mJ6A</recordid><startdate>201805</startdate><enddate>201805</enddate><creator>Hou, Xiao‐xia</creator><creator>Chu, Guang‐hua</creator><creator>Yu, Yuan</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-8082-5982</orcidid></search><sort><creationdate>201805</creationdate><title>Prospects of Contrast‐Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta‐analysis</title><author>Hou, Xiao‐xia ; Chu, Guang‐hua ; Yu, Yuan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3911-ef2259d4ca7106b39d36b4dedeef347f0b03fb761435c19a47ca5dd493e71feb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>angiopathy</topic><topic>atherosclerosis</topic><topic>Contrast Media</topic><topic>contrast‐enhanced ultrasonography</topic><topic>diagnosis</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>peripheral arterial disease</topic><topic>Peripheral Arterial Disease - diagnostic imaging</topic><topic>peripheral vascular</topic><topic>statistics</topic><topic>therapeutic</topic><topic>Ultrasonography - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hou, Xiao‐xia</creatorcontrib><creatorcontrib>Chu, Guang‐hua</creatorcontrib><creatorcontrib>Yu, Yuan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of ultrasound in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hou, Xiao‐xia</au><au>Chu, Guang‐hua</au><au>Yu, Yuan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Prospects of Contrast‐Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta‐analysis</atitle><jtitle>Journal of ultrasound in medicine</jtitle><addtitle>J Ultrasound Med</addtitle><date>2018-05</date><risdate>2018</risdate><volume>37</volume><issue>5</issue><spage>1081</spage><epage>1090</epage><pages>1081-1090</pages><issn>0278-4297</issn><eissn>1550-9613</eissn><abstract>Objectives Contrast‐enhanced ultrasonography (CEUS) is a modern diagnostic method that can also be used to study microperfusion. This study compared the time to peak intensity measured by CEUS in patients with peripheral arterial disease (PAD) and healthy control participants. Methods After a comprehensive literature search in multiple electronic databases and study selection, a random‐effect meta‐analysis was performed to compare the time to peak intensity measured by CEUS in patients with PAD and healthy controls, which followed meta‐regression analyses for identification of factors affecting the outcomes. Results Fourteen studies (data for 322 patients with PAD and 314 healthy individuals) were used for the meta‐analysis. The age of this sample of patients with PAD was 64.92 (95% confidence interval, 62.53, 67.31) years, and that of the healthy controls was 55.32 (51.67, 58.98) years. The times to peak intensity were 18.55 (15.62, 21.48) seconds in healthy controls, 33.40 (27.65, 39.15) seconds in patients with PAD, and 76.22 (36.23, 116.22) seconds in patients with PAD and diabetes mellitus. The difference between patients with PAD and healthy controls in the time to peak intensity was statistically significant (mean difference, 24.80 [10.16, 39.44] seconds; P &lt; .00009). The ABI was not significantly associated with the time to peak intensity in patients with PAD. Age and sex were also not significantly associated with the time to peak intensity. Conclusions Contrast‐enhanced ultrasonography is a valuable tool for the diagnosis of PAD based on its ability to differentiate the time to peak intensity between patients with PAD and healthy individuals, but little data are yet available to assess its diagnostic ability in clinical practice.</abstract><cop>England</cop><pmid>29064120</pmid><doi>10.1002/jum.14451</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0001-8082-5982</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0278-4297
ispartof Journal of ultrasound in medicine, 2018-05, Vol.37 (5), p.1081-1090
issn 0278-4297
1550-9613
language eng
recordid cdi_proquest_miscellaneous_1955067811
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects angiopathy
atherosclerosis
Contrast Media
contrast‐enhanced ultrasonography
diagnosis
Humans
Image Enhancement - methods
peripheral arterial disease
Peripheral Arterial Disease - diagnostic imaging
peripheral vascular
statistics
therapeutic
Ultrasonography - methods
title Prospects of Contrast‐Enhanced Ultrasonography for the Diagnosis of Peripheral Arterial Disease: A Meta‐analysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T18%3A28%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Prospects%20of%20Contrast%E2%80%90Enhanced%20Ultrasonography%20for%20the%20Diagnosis%20of%20Peripheral%20Arterial%20Disease:%20A%20Meta%E2%80%90analysis&rft.jtitle=Journal%20of%20ultrasound%20in%20medicine&rft.au=Hou,%20Xiao%E2%80%90xia&rft.date=2018-05&rft.volume=37&rft.issue=5&rft.spage=1081&rft.epage=1090&rft.pages=1081-1090&rft.issn=0278-4297&rft.eissn=1550-9613&rft_id=info:doi/10.1002/jum.14451&rft_dat=%3Cproquest_cross%3E1955067811%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1955067811&rft_id=info:pmid/29064120&rfr_iscdi=true