A portable precision ionization chamber: The transfer ionization reference chamber

A portable instrument was developed at the Institute of Radiation Physics (IRA) for on-site radionuclides measurements. It will enable the measurement of short-lived radionuclides in nuclear medicine departments or isotope production centres. The system involves an ionization chamber read directly b...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2018-04, Vol.134, p.95-99
Hauptverfasser: Juget, Frédéric, Nedjadi, Youcef, Buchillier, Thierry, Durán, Teresa, Bochud, François, Kottler, Christian, Bailat, Claude
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 99
container_issue
container_start_page 95
container_title Applied radiation and isotopes
container_volume 134
creator Juget, Frédéric
Nedjadi, Youcef
Buchillier, Thierry
Durán, Teresa
Bochud, François
Kottler, Christian
Bailat, Claude
description A portable instrument was developed at the Institute of Radiation Physics (IRA) for on-site radionuclides measurements. It will enable the measurement of short-lived radionuclides in nuclear medicine departments or isotope production centres. The system involves an ionization chamber read directly by an electrometer and it was optimized to ensure a good reproducibility through the selection of an appropriate vial, filling volume and source position in the well chamber, as well as monitoring the external background and performing a detailed uncertainty estimation. The calibration factors were determined using solutions whose activity concentration is traceable to the international reference system using the IRA reference chamber. Currently the transfer ionization chamber is calibrated for F-18, C-11, O-15, N-13, I-131 and Tc-99m. The final instrument is able to measure isotope activities with a relative standard uncertainty not larger than 1%. •We designed a portable ionization chamber for short half-lives nuclides activity measurement on site.•A precise estimation of the uncertainties was made allowing an accuracy less than 1%.•The chamber is calibrated using standardized reference samples.•External background is monitored using a probe in coincidence.•The chamber is validated with measurements of F-18 in production site and in a nuclear medicine department.
doi_str_mv 10.1016/j.apradiso.2017.10.022
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1954077543</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804317302440</els_id><sourcerecordid>1954077543</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-97ff05ce8dca813199a88916106f81150c118c70de0c2a464060cf34dd4fe1f3</originalsourceid><addsrcrecordid>eNqFkE1LAzEQhoMotlb_Qtmjl10nu9ndxJOl-AUFQXoPaXZCU_bLZCvorzdLW_HmIUx4eWYmeQiZU0go0OJul6jeqcr6LkmBliFMIE3PyJTyMo0FBzgnUxCFiDmwbEKuvN8BAOMivSSTVEDOWA5T8r6I-s4NalNj1DvU1tuujcKx32oYr3qrmg26-2i9xWhwqvUG3V_AYQiw1XhCr8mFUbXHm2OdkfXT43r5Eq_enl-Xi1Wss4IPsSiNgVwjr7TiNKNCKM4FLSgUhlOag6aU6xIqBJ0qVjAoQJuMVRUzSE02I7eHsb3rPvboB9lYr7GuVYvd3ksqcgZlmbMsoMUB1a7zPjxY9s42yn1JCnLUKXfypFOOOsc86AyN8-OO_abB6rft5C8ADwcAw0c_LTrptR1lVDbIHGTV2f92_AD6RopE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1954077543</pqid></control><display><type>article</type><title>A portable precision ionization chamber: The transfer ionization reference chamber</title><source>Elsevier ScienceDirect Journals</source><creator>Juget, Frédéric ; Nedjadi, Youcef ; Buchillier, Thierry ; Durán, Teresa ; Bochud, François ; Kottler, Christian ; Bailat, Claude</creator><creatorcontrib>Juget, Frédéric ; Nedjadi, Youcef ; Buchillier, Thierry ; Durán, Teresa ; Bochud, François ; Kottler, Christian ; Bailat, Claude</creatorcontrib><description>A portable instrument was developed at the Institute of Radiation Physics (IRA) for on-site radionuclides measurements. It will enable the measurement of short-lived radionuclides in nuclear medicine departments or isotope production centres. The system involves an ionization chamber read directly by an electrometer and it was optimized to ensure a good reproducibility through the selection of an appropriate vial, filling volume and source position in the well chamber, as well as monitoring the external background and performing a detailed uncertainty estimation. The calibration factors were determined using solutions whose activity concentration is traceable to the international reference system using the IRA reference chamber. Currently the transfer ionization chamber is calibrated for F-18, C-11, O-15, N-13, I-131 and Tc-99m. The final instrument is able to measure isotope activities with a relative standard uncertainty not larger than 1%. •We designed a portable ionization chamber for short half-lives nuclides activity measurement on site.•A precise estimation of the uncertainties was made allowing an accuracy less than 1%.•The chamber is calibrated using standardized reference samples.•External background is monitored using a probe in coincidence.•The chamber is validated with measurements of F-18 in production site and in a nuclear medicine department.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2017.10.022</identifier><identifier>PMID: 29054450</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Activity measurement ; Ionization chamber ; Nuclear medicine ; Short-lived nuclides ; Uncertainty estimation</subject><ispartof>Applied radiation and isotopes, 2018-04, Vol.134, p.95-99</ispartof><rights>2017 Elsevier Ltd</rights><rights>Copyright © 2017 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-97ff05ce8dca813199a88916106f81150c118c70de0c2a464060cf34dd4fe1f3</citedby><cites>FETCH-LOGICAL-c368t-97ff05ce8dca813199a88916106f81150c118c70de0c2a464060cf34dd4fe1f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0969804317302440$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29054450$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Juget, Frédéric</creatorcontrib><creatorcontrib>Nedjadi, Youcef</creatorcontrib><creatorcontrib>Buchillier, Thierry</creatorcontrib><creatorcontrib>Durán, Teresa</creatorcontrib><creatorcontrib>Bochud, François</creatorcontrib><creatorcontrib>Kottler, Christian</creatorcontrib><creatorcontrib>Bailat, Claude</creatorcontrib><title>A portable precision ionization chamber: The transfer ionization reference chamber</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>A portable instrument was developed at the Institute of Radiation Physics (IRA) for on-site radionuclides measurements. It will enable the measurement of short-lived radionuclides in nuclear medicine departments or isotope production centres. The system involves an ionization chamber read directly by an electrometer and it was optimized to ensure a good reproducibility through the selection of an appropriate vial, filling volume and source position in the well chamber, as well as monitoring the external background and performing a detailed uncertainty estimation. The calibration factors were determined using solutions whose activity concentration is traceable to the international reference system using the IRA reference chamber. Currently the transfer ionization chamber is calibrated for F-18, C-11, O-15, N-13, I-131 and Tc-99m. The final instrument is able to measure isotope activities with a relative standard uncertainty not larger than 1%. •We designed a portable ionization chamber for short half-lives nuclides activity measurement on site.•A precise estimation of the uncertainties was made allowing an accuracy less than 1%.•The chamber is calibrated using standardized reference samples.•External background is monitored using a probe in coincidence.•The chamber is validated with measurements of F-18 in production site and in a nuclear medicine department.</description><subject>Activity measurement</subject><subject>Ionization chamber</subject><subject>Nuclear medicine</subject><subject>Short-lived nuclides</subject><subject>Uncertainty estimation</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkE1LAzEQhoMotlb_Qtmjl10nu9ndxJOl-AUFQXoPaXZCU_bLZCvorzdLW_HmIUx4eWYmeQiZU0go0OJul6jeqcr6LkmBliFMIE3PyJTyMo0FBzgnUxCFiDmwbEKuvN8BAOMivSSTVEDOWA5T8r6I-s4NalNj1DvU1tuujcKx32oYr3qrmg26-2i9xWhwqvUG3V_AYQiw1XhCr8mFUbXHm2OdkfXT43r5Eq_enl-Xi1Wss4IPsSiNgVwjr7TiNKNCKM4FLSgUhlOag6aU6xIqBJ0qVjAoQJuMVRUzSE02I7eHsb3rPvboB9lYr7GuVYvd3ksqcgZlmbMsoMUB1a7zPjxY9s42yn1JCnLUKXfypFOOOsc86AyN8-OO_abB6rft5C8ADwcAw0c_LTrptR1lVDbIHGTV2f92_AD6RopE</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Juget, Frédéric</creator><creator>Nedjadi, Youcef</creator><creator>Buchillier, Thierry</creator><creator>Durán, Teresa</creator><creator>Bochud, François</creator><creator>Kottler, Christian</creator><creator>Bailat, Claude</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201804</creationdate><title>A portable precision ionization chamber: The transfer ionization reference chamber</title><author>Juget, Frédéric ; Nedjadi, Youcef ; Buchillier, Thierry ; Durán, Teresa ; Bochud, François ; Kottler, Christian ; Bailat, Claude</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-97ff05ce8dca813199a88916106f81150c118c70de0c2a464060cf34dd4fe1f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Activity measurement</topic><topic>Ionization chamber</topic><topic>Nuclear medicine</topic><topic>Short-lived nuclides</topic><topic>Uncertainty estimation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Juget, Frédéric</creatorcontrib><creatorcontrib>Nedjadi, Youcef</creatorcontrib><creatorcontrib>Buchillier, Thierry</creatorcontrib><creatorcontrib>Durán, Teresa</creatorcontrib><creatorcontrib>Bochud, François</creatorcontrib><creatorcontrib>Kottler, Christian</creatorcontrib><creatorcontrib>Bailat, Claude</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Juget, Frédéric</au><au>Nedjadi, Youcef</au><au>Buchillier, Thierry</au><au>Durán, Teresa</au><au>Bochud, François</au><au>Kottler, Christian</au><au>Bailat, Claude</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A portable precision ionization chamber: The transfer ionization reference chamber</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2018-04</date><risdate>2018</risdate><volume>134</volume><spage>95</spage><epage>99</epage><pages>95-99</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>A portable instrument was developed at the Institute of Radiation Physics (IRA) for on-site radionuclides measurements. It will enable the measurement of short-lived radionuclides in nuclear medicine departments or isotope production centres. The system involves an ionization chamber read directly by an electrometer and it was optimized to ensure a good reproducibility through the selection of an appropriate vial, filling volume and source position in the well chamber, as well as monitoring the external background and performing a detailed uncertainty estimation. The calibration factors were determined using solutions whose activity concentration is traceable to the international reference system using the IRA reference chamber. Currently the transfer ionization chamber is calibrated for F-18, C-11, O-15, N-13, I-131 and Tc-99m. The final instrument is able to measure isotope activities with a relative standard uncertainty not larger than 1%. •We designed a portable ionization chamber for short half-lives nuclides activity measurement on site.•A precise estimation of the uncertainties was made allowing an accuracy less than 1%.•The chamber is calibrated using standardized reference samples.•External background is monitored using a probe in coincidence.•The chamber is validated with measurements of F-18 in production site and in a nuclear medicine department.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>29054450</pmid><doi>10.1016/j.apradiso.2017.10.022</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0969-8043
ispartof Applied radiation and isotopes, 2018-04, Vol.134, p.95-99
issn 0969-8043
1872-9800
language eng
recordid cdi_proquest_miscellaneous_1954077543
source Elsevier ScienceDirect Journals
subjects Activity measurement
Ionization chamber
Nuclear medicine
Short-lived nuclides
Uncertainty estimation
title A portable precision ionization chamber: The transfer ionization reference chamber
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-18T22%3A54%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20portable%20precision%20ionization%20chamber:%20The%20transfer%20ionization%20reference%20chamber&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Juget,%20Fr%C3%A9d%C3%A9ric&rft.date=2018-04&rft.volume=134&rft.spage=95&rft.epage=99&rft.pages=95-99&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2017.10.022&rft_dat=%3Cproquest_cross%3E1954077543%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1954077543&rft_id=info:pmid/29054450&rft_els_id=S0969804317302440&rfr_iscdi=true