Protective effect of biodegradable nerve conduit against peripheral nerve adhesion after neurolysis

OBJECTIVE Peripheral nerve adhesion caused by extraneural and intraneural scar formation after neurolysis leads to nerve dysfunction. The authors previously developed a novel very flexible biodegradable nerve conduit composed of poly(L-lactide) and poly(ε-caprolactone) for use in peripheral nerve re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neurosurgery 2018-09, Vol.129 (3), p.815-824
Hauptverfasser: Shintani, Kosuke, Uemura, Takuya, Takamatsu, Kiyohito, Yokoi, Takuya, Onode, Ema, Okada, Mitsuhiro, Nakamura, Hiroaki
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 824
container_issue 3
container_start_page 815
container_title Journal of neurosurgery
container_volume 129
creator Shintani, Kosuke
Uemura, Takuya
Takamatsu, Kiyohito
Yokoi, Takuya
Onode, Ema
Okada, Mitsuhiro
Nakamura, Hiroaki
description OBJECTIVE Peripheral nerve adhesion caused by extraneural and intraneural scar formation after neurolysis leads to nerve dysfunction. The authors previously developed a novel very flexible biodegradable nerve conduit composed of poly(L-lactide) and poly(ε-caprolactone) for use in peripheral nerve regeneration. In the present study, they investigated the effect of protective nerve wrapping on preventing adhesion in a rat sciatic nerve adhesion model. METHODS Rat sciatic nerves were randomly assigned to one of the following four groups: a no-adhesion group, which involved neurolysis alone without an adhesion procedure; an adhesion group, in which the adhesion procedure was performed after neurolysis, but no treatment was subsequently administered; a nerve wrap group, in which the adhesion procedure was performed after neurolysis and protective nerve wrapping was then performed with the nerve conduit; and a hyaluronic acid (HA) group, in which the adhesion procedure was performed after neurolysis and nerve wrapping was then performed with a 1% sodium HA viscous solution. Six weeks postoperatively, the authors evaluated the extent of scar formation using adhesion scores and biomechanical and histological examinations and assessed nerve function with electrophysiological examination and gastrocnemius muscle weight measurement. RESULTS In the adhesion group, prominent scar tissue surrounded the nerve and strongly adhered to the nerve biomechanically and histologically. The motor nerve conduction velocity and gastrocnemius muscle weight were the lowest in this group. Conversely, the adhesion scores were significantly lower, motor nerve conduction velocity was significantly higher, and gastrocnemius muscle weight was significantly higher in the nerve wrap group than in the adhesion group. Additionally, the biomechanical breaking strength was significantly lower in the nerve wrap group than in the adhesion group and HA group. The morphological properties of axons in the nerve wrap group were preserved. Intraneural macrophage invasion, as assessed by the number of CD68- and CCR7-positive cells, was less severe in the nerve wrap group than in the adhesion group. CONCLUSIONS The nerve conduit prevented post-neurolysis peripheral nerves from developing adhesion and allowed them to maintain their nerve function because it effectively blocked scarring and prevented adhesion-related damage in the peripheral nerves.
doi_str_mv 10.3171/2017.4.jns162522
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1954070230</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1954070230</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-d9528371f3ac77184fa8d850b319b780eed2452f9a4097589ebca995380ee2143</originalsourceid><addsrcrecordid>eNo9kEtLw0AQxxdRbK3ePUmOXlJnX9nsUcQnRQX1HDbJbLslzcbdROi3N6XV0wzzfwz8CLmkMOdU0RsGVM3FfN1GmjHJ2BGZUs15Cpnmx2QKwFjKIZcTchbjGoBmImOnZMI0SA4qm5LqPfgeq979YILWjlvibVI6X-MymNqUDSYthlGtfFsPrk_M0rg29kmHwXUrDKY5GEy9wuh8mxjbYxiPQ_DNNrp4Tk6saSJeHOaMfD3cf949pYu3x-e720VaCVB9WmvJcq6o5aZSiubCmrzOJZSc6lLlgFgzIZnVRoBWMtdYVkZryXcSo4LPyPW-twv-e8DYFxsXK2wa06IfYkG1HB8B4zBaYW-tgo8xoC264DYmbAsKxQ5tsUNbiOLl9WOPdoxcHdqHcoP1f-CPJf8FoRJ1gg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1954070230</pqid></control><display><type>article</type><title>Protective effect of biodegradable nerve conduit against peripheral nerve adhesion after neurolysis</title><source>EZB Electronic Journals Library</source><creator>Shintani, Kosuke ; Uemura, Takuya ; Takamatsu, Kiyohito ; Yokoi, Takuya ; Onode, Ema ; Okada, Mitsuhiro ; Nakamura, Hiroaki</creator><creatorcontrib>Shintani, Kosuke ; Uemura, Takuya ; Takamatsu, Kiyohito ; Yokoi, Takuya ; Onode, Ema ; Okada, Mitsuhiro ; Nakamura, Hiroaki</creatorcontrib><description>OBJECTIVE Peripheral nerve adhesion caused by extraneural and intraneural scar formation after neurolysis leads to nerve dysfunction. The authors previously developed a novel very flexible biodegradable nerve conduit composed of poly(L-lactide) and poly(ε-caprolactone) for use in peripheral nerve regeneration. In the present study, they investigated the effect of protective nerve wrapping on preventing adhesion in a rat sciatic nerve adhesion model. METHODS Rat sciatic nerves were randomly assigned to one of the following four groups: a no-adhesion group, which involved neurolysis alone without an adhesion procedure; an adhesion group, in which the adhesion procedure was performed after neurolysis, but no treatment was subsequently administered; a nerve wrap group, in which the adhesion procedure was performed after neurolysis and protective nerve wrapping was then performed with the nerve conduit; and a hyaluronic acid (HA) group, in which the adhesion procedure was performed after neurolysis and nerve wrapping was then performed with a 1% sodium HA viscous solution. Six weeks postoperatively, the authors evaluated the extent of scar formation using adhesion scores and biomechanical and histological examinations and assessed nerve function with electrophysiological examination and gastrocnemius muscle weight measurement. RESULTS In the adhesion group, prominent scar tissue surrounded the nerve and strongly adhered to the nerve biomechanically and histologically. The motor nerve conduction velocity and gastrocnemius muscle weight were the lowest in this group. Conversely, the adhesion scores were significantly lower, motor nerve conduction velocity was significantly higher, and gastrocnemius muscle weight was significantly higher in the nerve wrap group than in the adhesion group. Additionally, the biomechanical breaking strength was significantly lower in the nerve wrap group than in the adhesion group and HA group. The morphological properties of axons in the nerve wrap group were preserved. Intraneural macrophage invasion, as assessed by the number of CD68- and CCR7-positive cells, was less severe in the nerve wrap group than in the adhesion group. CONCLUSIONS The nerve conduit prevented post-neurolysis peripheral nerves from developing adhesion and allowed them to maintain their nerve function because it effectively blocked scarring and prevented adhesion-related damage in the peripheral nerves.</description><identifier>ISSN: 0022-3085</identifier><identifier>EISSN: 1933-0693</identifier><identifier>DOI: 10.3171/2017.4.jns162522</identifier><identifier>PMID: 29053076</identifier><language>eng</language><publisher>United States</publisher><ispartof>Journal of neurosurgery, 2018-09, Vol.129 (3), p.815-824</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-d9528371f3ac77184fa8d850b319b780eed2452f9a4097589ebca995380ee2143</citedby><cites>FETCH-LOGICAL-c407t-d9528371f3ac77184fa8d850b319b780eed2452f9a4097589ebca995380ee2143</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29053076$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shintani, Kosuke</creatorcontrib><creatorcontrib>Uemura, Takuya</creatorcontrib><creatorcontrib>Takamatsu, Kiyohito</creatorcontrib><creatorcontrib>Yokoi, Takuya</creatorcontrib><creatorcontrib>Onode, Ema</creatorcontrib><creatorcontrib>Okada, Mitsuhiro</creatorcontrib><creatorcontrib>Nakamura, Hiroaki</creatorcontrib><title>Protective effect of biodegradable nerve conduit against peripheral nerve adhesion after neurolysis</title><title>Journal of neurosurgery</title><addtitle>J Neurosurg</addtitle><description>OBJECTIVE Peripheral nerve adhesion caused by extraneural and intraneural scar formation after neurolysis leads to nerve dysfunction. The authors previously developed a novel very flexible biodegradable nerve conduit composed of poly(L-lactide) and poly(ε-caprolactone) for use in peripheral nerve regeneration. In the present study, they investigated the effect of protective nerve wrapping on preventing adhesion in a rat sciatic nerve adhesion model. METHODS Rat sciatic nerves were randomly assigned to one of the following four groups: a no-adhesion group, which involved neurolysis alone without an adhesion procedure; an adhesion group, in which the adhesion procedure was performed after neurolysis, but no treatment was subsequently administered; a nerve wrap group, in which the adhesion procedure was performed after neurolysis and protective nerve wrapping was then performed with the nerve conduit; and a hyaluronic acid (HA) group, in which the adhesion procedure was performed after neurolysis and nerve wrapping was then performed with a 1% sodium HA viscous solution. Six weeks postoperatively, the authors evaluated the extent of scar formation using adhesion scores and biomechanical and histological examinations and assessed nerve function with electrophysiological examination and gastrocnemius muscle weight measurement. RESULTS In the adhesion group, prominent scar tissue surrounded the nerve and strongly adhered to the nerve biomechanically and histologically. The motor nerve conduction velocity and gastrocnemius muscle weight were the lowest in this group. Conversely, the adhesion scores were significantly lower, motor nerve conduction velocity was significantly higher, and gastrocnemius muscle weight was significantly higher in the nerve wrap group than in the adhesion group. Additionally, the biomechanical breaking strength was significantly lower in the nerve wrap group than in the adhesion group and HA group. The morphological properties of axons in the nerve wrap group were preserved. Intraneural macrophage invasion, as assessed by the number of CD68- and CCR7-positive cells, was less severe in the nerve wrap group than in the adhesion group. CONCLUSIONS The nerve conduit prevented post-neurolysis peripheral nerves from developing adhesion and allowed them to maintain their nerve function because it effectively blocked scarring and prevented adhesion-related damage in the peripheral nerves.</description><issn>0022-3085</issn><issn>1933-0693</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNo9kEtLw0AQxxdRbK3ePUmOXlJnX9nsUcQnRQX1HDbJbLslzcbdROi3N6XV0wzzfwz8CLmkMOdU0RsGVM3FfN1GmjHJ2BGZUs15Cpnmx2QKwFjKIZcTchbjGoBmImOnZMI0SA4qm5LqPfgeq979YILWjlvibVI6X-MymNqUDSYthlGtfFsPrk_M0rg29kmHwXUrDKY5GEy9wuh8mxjbYxiPQ_DNNrp4Tk6saSJeHOaMfD3cf949pYu3x-e720VaCVB9WmvJcq6o5aZSiubCmrzOJZSc6lLlgFgzIZnVRoBWMtdYVkZryXcSo4LPyPW-twv-e8DYFxsXK2wa06IfYkG1HB8B4zBaYW-tgo8xoC264DYmbAsKxQ5tsUNbiOLl9WOPdoxcHdqHcoP1f-CPJf8FoRJ1gg</recordid><startdate>201809</startdate><enddate>201809</enddate><creator>Shintani, Kosuke</creator><creator>Uemura, Takuya</creator><creator>Takamatsu, Kiyohito</creator><creator>Yokoi, Takuya</creator><creator>Onode, Ema</creator><creator>Okada, Mitsuhiro</creator><creator>Nakamura, Hiroaki</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201809</creationdate><title>Protective effect of biodegradable nerve conduit against peripheral nerve adhesion after neurolysis</title><author>Shintani, Kosuke ; Uemura, Takuya ; Takamatsu, Kiyohito ; Yokoi, Takuya ; Onode, Ema ; Okada, Mitsuhiro ; Nakamura, Hiroaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-d9528371f3ac77184fa8d850b319b780eed2452f9a4097589ebca995380ee2143</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shintani, Kosuke</creatorcontrib><creatorcontrib>Uemura, Takuya</creatorcontrib><creatorcontrib>Takamatsu, Kiyohito</creatorcontrib><creatorcontrib>Yokoi, Takuya</creatorcontrib><creatorcontrib>Onode, Ema</creatorcontrib><creatorcontrib>Okada, Mitsuhiro</creatorcontrib><creatorcontrib>Nakamura, Hiroaki</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neurosurgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shintani, Kosuke</au><au>Uemura, Takuya</au><au>Takamatsu, Kiyohito</au><au>Yokoi, Takuya</au><au>Onode, Ema</au><au>Okada, Mitsuhiro</au><au>Nakamura, Hiroaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Protective effect of biodegradable nerve conduit against peripheral nerve adhesion after neurolysis</atitle><jtitle>Journal of neurosurgery</jtitle><addtitle>J Neurosurg</addtitle><date>2018-09</date><risdate>2018</risdate><volume>129</volume><issue>3</issue><spage>815</spage><epage>824</epage><pages>815-824</pages><issn>0022-3085</issn><eissn>1933-0693</eissn><abstract>OBJECTIVE Peripheral nerve adhesion caused by extraneural and intraneural scar formation after neurolysis leads to nerve dysfunction. The authors previously developed a novel very flexible biodegradable nerve conduit composed of poly(L-lactide) and poly(ε-caprolactone) for use in peripheral nerve regeneration. In the present study, they investigated the effect of protective nerve wrapping on preventing adhesion in a rat sciatic nerve adhesion model. METHODS Rat sciatic nerves were randomly assigned to one of the following four groups: a no-adhesion group, which involved neurolysis alone without an adhesion procedure; an adhesion group, in which the adhesion procedure was performed after neurolysis, but no treatment was subsequently administered; a nerve wrap group, in which the adhesion procedure was performed after neurolysis and protective nerve wrapping was then performed with the nerve conduit; and a hyaluronic acid (HA) group, in which the adhesion procedure was performed after neurolysis and nerve wrapping was then performed with a 1% sodium HA viscous solution. Six weeks postoperatively, the authors evaluated the extent of scar formation using adhesion scores and biomechanical and histological examinations and assessed nerve function with electrophysiological examination and gastrocnemius muscle weight measurement. RESULTS In the adhesion group, prominent scar tissue surrounded the nerve and strongly adhered to the nerve biomechanically and histologically. The motor nerve conduction velocity and gastrocnemius muscle weight were the lowest in this group. Conversely, the adhesion scores were significantly lower, motor nerve conduction velocity was significantly higher, and gastrocnemius muscle weight was significantly higher in the nerve wrap group than in the adhesion group. Additionally, the biomechanical breaking strength was significantly lower in the nerve wrap group than in the adhesion group and HA group. The morphological properties of axons in the nerve wrap group were preserved. Intraneural macrophage invasion, as assessed by the number of CD68- and CCR7-positive cells, was less severe in the nerve wrap group than in the adhesion group. CONCLUSIONS The nerve conduit prevented post-neurolysis peripheral nerves from developing adhesion and allowed them to maintain their nerve function because it effectively blocked scarring and prevented adhesion-related damage in the peripheral nerves.</abstract><cop>United States</cop><pmid>29053076</pmid><doi>10.3171/2017.4.jns162522</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0022-3085
ispartof Journal of neurosurgery, 2018-09, Vol.129 (3), p.815-824
issn 0022-3085
1933-0693
language eng
recordid cdi_proquest_miscellaneous_1954070230
source EZB Electronic Journals Library
title Protective effect of biodegradable nerve conduit against peripheral nerve adhesion after neurolysis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T18%3A28%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Protective%20effect%20of%20biodegradable%20nerve%20conduit%20against%20peripheral%20nerve%20adhesion%20after%20neurolysis&rft.jtitle=Journal%20of%20neurosurgery&rft.au=Shintani,%20Kosuke&rft.date=2018-09&rft.volume=129&rft.issue=3&rft.spage=815&rft.epage=824&rft.pages=815-824&rft.issn=0022-3085&rft.eissn=1933-0693&rft_id=info:doi/10.3171/2017.4.jns162522&rft_dat=%3Cproquest_cross%3E1954070230%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1954070230&rft_id=info:pmid/29053076&rfr_iscdi=true