Geant4 based Monte Carlo simulation for verifying the modified sum-peak method

The modified sum-peak method can practically estimate radioactivity by using solely the peak and the sum peak count rate. In order to efficiently verify the method in various experimental conditions, a Geant4 based Monte Carlo simulation for a high-purity germanium detector system was applied. The e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2018-04, Vol.134, p.147-150
Hauptverfasser: Aso, Tsukasa, Ogata, Yoshimune, Makino, Ryuta
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 150
container_issue
container_start_page 147
container_title Applied radiation and isotopes
container_volume 134
creator Aso, Tsukasa
Ogata, Yoshimune
Makino, Ryuta
description The modified sum-peak method can practically estimate radioactivity by using solely the peak and the sum peak count rate. In order to efficiently verify the method in various experimental conditions, a Geant4 based Monte Carlo simulation for a high-purity germanium detector system was applied. The energy spectra in the detector were simulated for a 60Co point source in various source to detector distances. The calculated radioactivity shows good agreement with the number of decays in the simulation. •Monte Carlo simulation, Geant4, was applied to simulating the sum-peak method via a HP-Ge detector.•A 60Co point source was the used to the simulation.•The simulation was validated in peak-shape and relative efficiency of the HP-Ge detector.•Both the conventional sum-peak method and the modified sum-peak method was validated.•The modified sum-peak method was confirmed as a practical technique in the simulation.
doi_str_mv 10.1016/j.apradiso.2017.09.013
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1951570586</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804317302130</els_id><sourcerecordid>1951570586</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-b1f069d648d8ded700b514258779594c02a2406576d4b06e9c6123d0c4a9138a3</originalsourceid><addsrcrecordid>eNqFkLFu2zAURYmiReM4_YWAYxcpjxRFkVsLo3ECOO3SzARFPjV0JdElJQP5-yhw3DXTW869F-8Qcs2gZMDkzb60h2R9yLHkwJoSdAms-kBWTDW80ArgI1mBlrpQIKoLcpnzHgCE0vwzueAaKq4avSI_t2jHSdDWZvT0IY4T0o1NfaQ5DHNvpxBH2sVEj5hC9xzGP3R6QjpEH7qwJPI8FAe0f-mA01P0V-RTZ_uMX97umjze_vi9uSt2v7b3m--7wlVSTUXLOpDaS6G88ugbgLZmgteqaXSthQNuuQBZN9KLFiRqJxmvPDhhNauUrdbk66n3kOK_GfNkhpAd9r0dMc7ZMF2zuoFayQWVJ9SlmHPCzhxSGGx6NgzMq0uzN2eX5tWlAW0Wl0vw-m1jbgf0_2NneQvw7QTg8ukxYDLZBRwd-pDQTcbH8N7GC1boh6M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1951570586</pqid></control><display><type>article</type><title>Geant4 based Monte Carlo simulation for verifying the modified sum-peak method</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Aso, Tsukasa ; Ogata, Yoshimune ; Makino, Ryuta</creator><creatorcontrib>Aso, Tsukasa ; Ogata, Yoshimune ; Makino, Ryuta</creatorcontrib><description>The modified sum-peak method can practically estimate radioactivity by using solely the peak and the sum peak count rate. In order to efficiently verify the method in various experimental conditions, a Geant4 based Monte Carlo simulation for a high-purity germanium detector system was applied. The energy spectra in the detector were simulated for a 60Co point source in various source to detector distances. The calculated radioactivity shows good agreement with the number of decays in the simulation. •Monte Carlo simulation, Geant4, was applied to simulating the sum-peak method via a HP-Ge detector.•A 60Co point source was the used to the simulation.•The simulation was validated in peak-shape and relative efficiency of the HP-Ge detector.•Both the conventional sum-peak method and the modified sum-peak method was validated.•The modified sum-peak method was confirmed as a practical technique in the simulation.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2017.09.013</identifier><identifier>PMID: 29032879</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>60Co ; Absolute measurement of radioactivity ; Geant4 simulation ; Sum-peak method</subject><ispartof>Applied radiation and isotopes, 2018-04, Vol.134, p.147-150</ispartof><rights>2017 Elsevier Ltd</rights><rights>Copyright © 2017 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-b1f069d648d8ded700b514258779594c02a2406576d4b06e9c6123d0c4a9138a3</citedby><cites>FETCH-LOGICAL-c368t-b1f069d648d8ded700b514258779594c02a2406576d4b06e9c6123d0c4a9138a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apradiso.2017.09.013$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29032879$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Aso, Tsukasa</creatorcontrib><creatorcontrib>Ogata, Yoshimune</creatorcontrib><creatorcontrib>Makino, Ryuta</creatorcontrib><title>Geant4 based Monte Carlo simulation for verifying the modified sum-peak method</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>The modified sum-peak method can practically estimate radioactivity by using solely the peak and the sum peak count rate. In order to efficiently verify the method in various experimental conditions, a Geant4 based Monte Carlo simulation for a high-purity germanium detector system was applied. The energy spectra in the detector were simulated for a 60Co point source in various source to detector distances. The calculated radioactivity shows good agreement with the number of decays in the simulation. •Monte Carlo simulation, Geant4, was applied to simulating the sum-peak method via a HP-Ge detector.•A 60Co point source was the used to the simulation.•The simulation was validated in peak-shape and relative efficiency of the HP-Ge detector.•Both the conventional sum-peak method and the modified sum-peak method was validated.•The modified sum-peak method was confirmed as a practical technique in the simulation.</description><subject>60Co</subject><subject>Absolute measurement of radioactivity</subject><subject>Geant4 simulation</subject><subject>Sum-peak method</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkLFu2zAURYmiReM4_YWAYxcpjxRFkVsLo3ECOO3SzARFPjV0JdElJQP5-yhw3DXTW869F-8Qcs2gZMDkzb60h2R9yLHkwJoSdAms-kBWTDW80ArgI1mBlrpQIKoLcpnzHgCE0vwzueAaKq4avSI_t2jHSdDWZvT0IY4T0o1NfaQ5DHNvpxBH2sVEj5hC9xzGP3R6QjpEH7qwJPI8FAe0f-mA01P0V-RTZ_uMX97umjze_vi9uSt2v7b3m--7wlVSTUXLOpDaS6G88ugbgLZmgteqaXSthQNuuQBZN9KLFiRqJxmvPDhhNauUrdbk66n3kOK_GfNkhpAd9r0dMc7ZMF2zuoFayQWVJ9SlmHPCzhxSGGx6NgzMq0uzN2eX5tWlAW0Wl0vw-m1jbgf0_2NneQvw7QTg8ukxYDLZBRwd-pDQTcbH8N7GC1boh6M</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Aso, Tsukasa</creator><creator>Ogata, Yoshimune</creator><creator>Makino, Ryuta</creator><general>Elsevier Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201804</creationdate><title>Geant4 based Monte Carlo simulation for verifying the modified sum-peak method</title><author>Aso, Tsukasa ; Ogata, Yoshimune ; Makino, Ryuta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-b1f069d648d8ded700b514258779594c02a2406576d4b06e9c6123d0c4a9138a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>60Co</topic><topic>Absolute measurement of radioactivity</topic><topic>Geant4 simulation</topic><topic>Sum-peak method</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aso, Tsukasa</creatorcontrib><creatorcontrib>Ogata, Yoshimune</creatorcontrib><creatorcontrib>Makino, Ryuta</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aso, Tsukasa</au><au>Ogata, Yoshimune</au><au>Makino, Ryuta</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Geant4 based Monte Carlo simulation for verifying the modified sum-peak method</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2018-04</date><risdate>2018</risdate><volume>134</volume><spage>147</spage><epage>150</epage><pages>147-150</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>The modified sum-peak method can practically estimate radioactivity by using solely the peak and the sum peak count rate. In order to efficiently verify the method in various experimental conditions, a Geant4 based Monte Carlo simulation for a high-purity germanium detector system was applied. The energy spectra in the detector were simulated for a 60Co point source in various source to detector distances. The calculated radioactivity shows good agreement with the number of decays in the simulation. •Monte Carlo simulation, Geant4, was applied to simulating the sum-peak method via a HP-Ge detector.•A 60Co point source was the used to the simulation.•The simulation was validated in peak-shape and relative efficiency of the HP-Ge detector.•Both the conventional sum-peak method and the modified sum-peak method was validated.•The modified sum-peak method was confirmed as a practical technique in the simulation.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>29032879</pmid><doi>10.1016/j.apradiso.2017.09.013</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0969-8043
ispartof Applied radiation and isotopes, 2018-04, Vol.134, p.147-150
issn 0969-8043
1872-9800
language eng
recordid cdi_proquest_miscellaneous_1951570586
source ScienceDirect Journals (5 years ago - present)
subjects 60Co
Absolute measurement of radioactivity
Geant4 simulation
Sum-peak method
title Geant4 based Monte Carlo simulation for verifying the modified sum-peak method
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T10%3A10%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Geant4%20based%20Monte%20Carlo%20simulation%20for%20verifying%20the%20modified%20sum-peak%20method&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Aso,%20Tsukasa&rft.date=2018-04&rft.volume=134&rft.spage=147&rft.epage=150&rft.pages=147-150&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2017.09.013&rft_dat=%3Cproquest_cross%3E1951570586%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1951570586&rft_id=info:pmid/29032879&rft_els_id=S0969804317302130&rfr_iscdi=true