User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets
Abstract The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this...
Gespeichert in:
Veröffentlicht in: | Journal of chromatographic science 2017-11, Vol.55 (10), p.979-988 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 988 |
---|---|
container_issue | 10 |
container_start_page | 979 |
container_title | Journal of chromatographic science |
container_volume | 55 |
creator | Koppala, Srinivasarao Ranga Reddy, V Anireddy, Jaya Shree |
description | Abstract
The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time. |
doi_str_mv | 10.1093/chromsci/bmx060 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1948759756</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/chromsci/bmx060</oup_id><sourcerecordid>1948759756</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</originalsourceid><addsrcrecordid>eNqFkM9PwyAYhonRuDk9ezMcjUldoaO0RzN_bMmMHtR4ayh8zTC0VKBGz_7jdtYZb56A73veN-RB6JjE5yTOk6lcO1t7qadl_R6n8Q4ak3zGIprkz7toHMeURHmashE68P5l8yQZ20cjmuUZo5yO0eejBxddOw2NMh94cb-a41sIa6vwJbyBsW0NTcCiUfhJGK1E0LbBlXX9OoCrdTNMbIWvGmFE67TBt8KACPCdWgaPl3XbOR00eKybP9yDKA0Ef4j2KmE8HP2cE_R4ffUwX0Sru5vl_GIVyYQnIZIzQqRUJOOCpllMMiUSqgidlbyaSd7fVcl4mQInlEOVMtFrYKJK8qxSgtJkgk6H3tbZ1w58KGrtJRgjGrCdL3p1GWc5Z2mPTgdUOuu9g6roP1wL91GQuNiYL7bmi8F8nzj5Ke_KGtQvv1XdA2cDYLv237Yv7V6SXA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1948759756</pqid></control><display><type>article</type><title>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Koppala, Srinivasarao ; Ranga Reddy, V ; Anireddy, Jaya Shree</creator><creatorcontrib>Koppala, Srinivasarao ; Ranga Reddy, V ; Anireddy, Jaya Shree</creatorcontrib><description>Abstract
The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.</description><identifier>ISSN: 0021-9665</identifier><identifier>EISSN: 1945-239X</identifier><identifier>DOI: 10.1093/chromsci/bmx060</identifier><identifier>PMID: 28985272</identifier><language>eng</language><publisher>United States: Oxford University Press</publisher><ispartof>Journal of chromatographic science, 2017-11, Vol.55 (10), p.979-988</ispartof><rights>The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com 2017</rights><rights>The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</citedby><cites>FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,1579,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28985272$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Koppala, Srinivasarao</creatorcontrib><creatorcontrib>Ranga Reddy, V</creatorcontrib><creatorcontrib>Anireddy, Jaya Shree</creatorcontrib><title>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</title><title>Journal of chromatographic science</title><addtitle>J Chromatogr Sci</addtitle><description>Abstract
The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.</description><issn>0021-9665</issn><issn>1945-239X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqFkM9PwyAYhonRuDk9ezMcjUldoaO0RzN_bMmMHtR4ayh8zTC0VKBGz_7jdtYZb56A73veN-RB6JjE5yTOk6lcO1t7qadl_R6n8Q4ak3zGIprkz7toHMeURHmashE68P5l8yQZ20cjmuUZo5yO0eejBxddOw2NMh94cb-a41sIa6vwJbyBsW0NTcCiUfhJGK1E0LbBlXX9OoCrdTNMbIWvGmFE67TBt8KACPCdWgaPl3XbOR00eKybP9yDKA0Ef4j2KmE8HP2cE_R4ffUwX0Sru5vl_GIVyYQnIZIzQqRUJOOCpllMMiUSqgidlbyaSd7fVcl4mQInlEOVMtFrYKJK8qxSgtJkgk6H3tbZ1w58KGrtJRgjGrCdL3p1GWc5Z2mPTgdUOuu9g6roP1wL91GQuNiYL7bmi8F8nzj5Ke_KGtQvv1XdA2cDYLv237Yv7V6SXA</recordid><startdate>20171101</startdate><enddate>20171101</enddate><creator>Koppala, Srinivasarao</creator><creator>Ranga Reddy, V</creator><creator>Anireddy, Jaya Shree</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20171101</creationdate><title>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</title><author>Koppala, Srinivasarao ; Ranga Reddy, V ; Anireddy, Jaya Shree</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Koppala, Srinivasarao</creatorcontrib><creatorcontrib>Ranga Reddy, V</creatorcontrib><creatorcontrib>Anireddy, Jaya Shree</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatographic science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Koppala, Srinivasarao</au><au>Ranga Reddy, V</au><au>Anireddy, Jaya Shree</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</atitle><jtitle>Journal of chromatographic science</jtitle><addtitle>J Chromatogr Sci</addtitle><date>2017-11-01</date><risdate>2017</risdate><volume>55</volume><issue>10</issue><spage>979</spage><epage>988</epage><pages>979-988</pages><issn>0021-9665</issn><eissn>1945-239X</eissn><abstract>Abstract
The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.</abstract><cop>United States</cop><pub>Oxford University Press</pub><pmid>28985272</pmid><doi>10.1093/chromsci/bmx060</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-9665 |
ispartof | Journal of chromatographic science, 2017-11, Vol.55 (10), p.979-988 |
issn | 0021-9665 1945-239X |
language | eng |
recordid | cdi_proquest_miscellaneous_1948759756 |
source | Oxford University Press Journals All Titles (1996-Current); EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry |
title | User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T18%3A09%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=User-Friendly%20HPLC%20Method%20Development%20and%20Validation%20for%20Determination%20of%20Enalapril%20Maleate%20and%20Its%20Impurities%20in%20Enalapril%20Tablets&rft.jtitle=Journal%20of%20chromatographic%20science&rft.au=Koppala,%20Srinivasarao&rft.date=2017-11-01&rft.volume=55&rft.issue=10&rft.spage=979&rft.epage=988&rft.pages=979-988&rft.issn=0021-9665&rft.eissn=1945-239X&rft_id=info:doi/10.1093/chromsci/bmx060&rft_dat=%3Cproquest_cross%3E1948759756%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1948759756&rft_id=info:pmid/28985272&rft_oup_id=10.1093/chromsci/bmx060&rfr_iscdi=true |