Molecular Distillation
Molecular distillation was studied for the separation of tocopherols from soya sludge, both experimentally and by simulation, under different operating conditions, with good agreement. Evaporator temperatures varied from 100°C to 160°C and feed flow rates ranged from 0.1 to 0.8 kg/h. The process pre...
Gespeichert in:
Veröffentlicht in: | Applied biochemistry and biotechnology 2006-01, Vol.132 (1-3), p.1066-1076 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Molecular distillation was studied for the separation of tocopherols from soya sludge, both experimentally and by simulation, under different operating conditions, with good agreement. Evaporator temperatures varied from 100°C to 160°C and feed flow rates ranged from 0.1 to 0.8 kg/h. The process pressure was maintained at 10−6 bar, the feed temperature at 50°C, the condenser temperature at 60°C, and the stirring at 350 rpm. For each process condition, samples of both streams (distillate and residue) were collected and stored at −18°C before tocopherols analyses. Owing to the differences between molecular weights and vapor pressures of free fatty acids and tocopherols, tocopherols preferentially remained in the residue at evaporator temperatures of 100°C and 120°C, whereas for higher temperatures (140°C and 160°C) and lower feed flow rate, tocopherols tended to migrate to the distillate stream. |
---|---|
ISSN: | 0273-2289 0273-2289 1559-0291 |
DOI: | 10.1385/ABAB:132:1:1066 |