Parsimonious calibration models for near-infrared spectroscopy using wavelets and scaling functions

In this study, the utility of Haar wavelet and Haar scaling function preprocessing of near-infrared (NIR) spectra was investigated in view of obtaining more parsimonious calibration models than using single wavelength selection algorithms. To evaluate these processing schemes, three data sets were a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemometrics and intelligent laboratory systems 2006-07, Vol.83 (1), p.44-53
Hauptverfasser: Gributs, Claudia E.W., Burns, David H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 53
container_issue 1
container_start_page 44
container_title Chemometrics and intelligent laboratory systems
container_volume 83
creator Gributs, Claudia E.W.
Burns, David H.
description In this study, the utility of Haar wavelet and Haar scaling function preprocessing of near-infrared (NIR) spectra was investigated in view of obtaining more parsimonious calibration models than using single wavelength selection algorithms. To evaluate these processing schemes, three data sets were analyzed. The first consisted of a previously well-studied set of wheat spectra, with known moisture content values. Also, myoglobin oxygen saturation or sample temperature were quantified from NIR spectra of tissue phantoms. For all of the above spectra, a genetic algorithm was used to choose a simple combination of either wavelengths or wavelets to parsimoniously estimate the property of interest. Since each data set analyzed was known to have different preprocessing requirements to yield low errors of prediction, it was possible to show how adaptable Haar wavelets and scaling functions are under different conditions. The need for trial and error preprocessing to obtain good calibrations was reduced. Furthermore, it was found that multiresolution analysis preprocessing before variable selection led to simpler models with lower errors than single-wavelength selection. In particular, scaling functions (or “son” Haar wavelets) gave the most parsimonious models. Since son wavelet models are easy to interpret and are straightforward to implement in an instrument, Haar scaling function preprocessing is a useful tool for building simplified NIR instrumentation. In the long term, these simplified instruments could be used to improve the speed and accuracy of quantification in on-line processes or clinical measurements.
doi_str_mv 10.1016/j.chemolab.2005.12.007
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_19443238</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0169743906000025</els_id><sourcerecordid>19443238</sourcerecordid><originalsourceid>FETCH-LOGICAL-c343t-e56464c5db3adcfe4074c9311470ae30eaeae4ba95151dd8a05ae6437fe15aaf3</originalsourceid><addsrcrecordid>eNqFkE9LxDAQxYMouK5-BcnJW2vSpO32piz-gwU96DlMk6lmaZM1aVf89qasnmUOw8y8efB-hFxylnPGq-ttrj9w8D20ecFYmfMiZ6w-Igu-qkUmCtEck0USNlktRXNKzmLcsnmWfEH0C4RoB--snyLV0Ns2wGi9o4M32Efa-UAdQsis6wIENDTuUI_BR-1333SK1r3TL9hjj2Ok4NJ9dknLbnJ6dorn5KSDPuLFb1-St_u71_Vjtnl-eFrfbjItpBgzLCtZSV2aVoDRHUpWS90IzmXNAAVDSCVbaEpecmNWwErASoq6Q14CdGJJrg6-u-A_J4yjGmzU2PfgMKVTvJEy4VglYXUQ6hQjBuzULtgBwrfiTM1M1Vb9MVUzU8ULlZimx5vDYyKDe4tBRW3RaTQ2JCjKePufxQ-OnYbY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19443238</pqid></control><display><type>article</type><title>Parsimonious calibration models for near-infrared spectroscopy using wavelets and scaling functions</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Gributs, Claudia E.W. ; Burns, David H.</creator><creatorcontrib>Gributs, Claudia E.W. ; Burns, David H.</creatorcontrib><description>In this study, the utility of Haar wavelet and Haar scaling function preprocessing of near-infrared (NIR) spectra was investigated in view of obtaining more parsimonious calibration models than using single wavelength selection algorithms. To evaluate these processing schemes, three data sets were analyzed. The first consisted of a previously well-studied set of wheat spectra, with known moisture content values. Also, myoglobin oxygen saturation or sample temperature were quantified from NIR spectra of tissue phantoms. For all of the above spectra, a genetic algorithm was used to choose a simple combination of either wavelengths or wavelets to parsimoniously estimate the property of interest. Since each data set analyzed was known to have different preprocessing requirements to yield low errors of prediction, it was possible to show how adaptable Haar wavelets and scaling functions are under different conditions. The need for trial and error preprocessing to obtain good calibrations was reduced. Furthermore, it was found that multiresolution analysis preprocessing before variable selection led to simpler models with lower errors than single-wavelength selection. In particular, scaling functions (or “son” Haar wavelets) gave the most parsimonious models. Since son wavelet models are easy to interpret and are straightforward to implement in an instrument, Haar scaling function preprocessing is a useful tool for building simplified NIR instrumentation. In the long term, these simplified instruments could be used to improve the speed and accuracy of quantification in on-line processes or clinical measurements.</description><identifier>ISSN: 0169-7439</identifier><identifier>EISSN: 1873-3239</identifier><identifier>DOI: 10.1016/j.chemolab.2005.12.007</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Triticum aestivum</subject><ispartof>Chemometrics and intelligent laboratory systems, 2006-07, Vol.83 (1), p.44-53</ispartof><rights>2006 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c343t-e56464c5db3adcfe4074c9311470ae30eaeae4ba95151dd8a05ae6437fe15aaf3</citedby><cites>FETCH-LOGICAL-c343t-e56464c5db3adcfe4074c9311470ae30eaeae4ba95151dd8a05ae6437fe15aaf3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.chemolab.2005.12.007$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Gributs, Claudia E.W.</creatorcontrib><creatorcontrib>Burns, David H.</creatorcontrib><title>Parsimonious calibration models for near-infrared spectroscopy using wavelets and scaling functions</title><title>Chemometrics and intelligent laboratory systems</title><description>In this study, the utility of Haar wavelet and Haar scaling function preprocessing of near-infrared (NIR) spectra was investigated in view of obtaining more parsimonious calibration models than using single wavelength selection algorithms. To evaluate these processing schemes, three data sets were analyzed. The first consisted of a previously well-studied set of wheat spectra, with known moisture content values. Also, myoglobin oxygen saturation or sample temperature were quantified from NIR spectra of tissue phantoms. For all of the above spectra, a genetic algorithm was used to choose a simple combination of either wavelengths or wavelets to parsimoniously estimate the property of interest. Since each data set analyzed was known to have different preprocessing requirements to yield low errors of prediction, it was possible to show how adaptable Haar wavelets and scaling functions are under different conditions. The need for trial and error preprocessing to obtain good calibrations was reduced. Furthermore, it was found that multiresolution analysis preprocessing before variable selection led to simpler models with lower errors than single-wavelength selection. In particular, scaling functions (or “son” Haar wavelets) gave the most parsimonious models. Since son wavelet models are easy to interpret and are straightforward to implement in an instrument, Haar scaling function preprocessing is a useful tool for building simplified NIR instrumentation. In the long term, these simplified instruments could be used to improve the speed and accuracy of quantification in on-line processes or clinical measurements.</description><subject>Triticum aestivum</subject><issn>0169-7439</issn><issn>1873-3239</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqFkE9LxDAQxYMouK5-BcnJW2vSpO32piz-gwU96DlMk6lmaZM1aVf89qasnmUOw8y8efB-hFxylnPGq-ttrj9w8D20ecFYmfMiZ6w-Igu-qkUmCtEck0USNlktRXNKzmLcsnmWfEH0C4RoB--snyLV0Ns2wGi9o4M32Efa-UAdQsis6wIENDTuUI_BR-1333SK1r3TL9hjj2Ok4NJ9dknLbnJ6dorn5KSDPuLFb1-St_u71_Vjtnl-eFrfbjItpBgzLCtZSV2aVoDRHUpWS90IzmXNAAVDSCVbaEpecmNWwErASoq6Q14CdGJJrg6-u-A_J4yjGmzU2PfgMKVTvJEy4VglYXUQ6hQjBuzULtgBwrfiTM1M1Vb9MVUzU8ULlZimx5vDYyKDe4tBRW3RaTQ2JCjKePufxQ-OnYbY</recordid><startdate>20060707</startdate><enddate>20060707</enddate><creator>Gributs, Claudia E.W.</creator><creator>Burns, David H.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20060707</creationdate><title>Parsimonious calibration models for near-infrared spectroscopy using wavelets and scaling functions</title><author>Gributs, Claudia E.W. ; Burns, David H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c343t-e56464c5db3adcfe4074c9311470ae30eaeae4ba95151dd8a05ae6437fe15aaf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Triticum aestivum</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gributs, Claudia E.W.</creatorcontrib><creatorcontrib>Burns, David H.</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Chemometrics and intelligent laboratory systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gributs, Claudia E.W.</au><au>Burns, David H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Parsimonious calibration models for near-infrared spectroscopy using wavelets and scaling functions</atitle><jtitle>Chemometrics and intelligent laboratory systems</jtitle><date>2006-07-07</date><risdate>2006</risdate><volume>83</volume><issue>1</issue><spage>44</spage><epage>53</epage><pages>44-53</pages><issn>0169-7439</issn><eissn>1873-3239</eissn><abstract>In this study, the utility of Haar wavelet and Haar scaling function preprocessing of near-infrared (NIR) spectra was investigated in view of obtaining more parsimonious calibration models than using single wavelength selection algorithms. To evaluate these processing schemes, three data sets were analyzed. The first consisted of a previously well-studied set of wheat spectra, with known moisture content values. Also, myoglobin oxygen saturation or sample temperature were quantified from NIR spectra of tissue phantoms. For all of the above spectra, a genetic algorithm was used to choose a simple combination of either wavelengths or wavelets to parsimoniously estimate the property of interest. Since each data set analyzed was known to have different preprocessing requirements to yield low errors of prediction, it was possible to show how adaptable Haar wavelets and scaling functions are under different conditions. The need for trial and error preprocessing to obtain good calibrations was reduced. Furthermore, it was found that multiresolution analysis preprocessing before variable selection led to simpler models with lower errors than single-wavelength selection. In particular, scaling functions (or “son” Haar wavelets) gave the most parsimonious models. Since son wavelet models are easy to interpret and are straightforward to implement in an instrument, Haar scaling function preprocessing is a useful tool for building simplified NIR instrumentation. In the long term, these simplified instruments could be used to improve the speed and accuracy of quantification in on-line processes or clinical measurements.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.chemolab.2005.12.007</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0169-7439
ispartof Chemometrics and intelligent laboratory systems, 2006-07, Vol.83 (1), p.44-53
issn 0169-7439
1873-3239
language eng
recordid cdi_proquest_miscellaneous_19443238
source Elsevier ScienceDirect Journals Complete
subjects Triticum aestivum
title Parsimonious calibration models for near-infrared spectroscopy using wavelets and scaling functions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T09%3A31%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Parsimonious%20calibration%20models%20for%20near-infrared%20spectroscopy%20using%20wavelets%20and%20scaling%20functions&rft.jtitle=Chemometrics%20and%20intelligent%20laboratory%20systems&rft.au=Gributs,%20Claudia%20E.W.&rft.date=2006-07-07&rft.volume=83&rft.issue=1&rft.spage=44&rft.epage=53&rft.pages=44-53&rft.issn=0169-7439&rft.eissn=1873-3239&rft_id=info:doi/10.1016/j.chemolab.2005.12.007&rft_dat=%3Cproquest_cross%3E19443238%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=19443238&rft_id=info:pmid/&rft_els_id=S0169743906000025&rfr_iscdi=true