Electrochemical nitric oxide biosensor based on amine-modified MoS2/graphene oxide/myoglobin hybrid
[Display omitted] •The nitric oxide biosensor was developed by amine-modified MoS2/GO/Mb hybrid.•For the first time, synthesis of MoS2 accompanying the amine-modification was done.•The hybrid showed the increase of electrochemical signal and amperometric response.•The hybrid showed high selectivity...
Gespeichert in:
Veröffentlicht in: | Colloids and surfaces, B, Biointerfaces B, Biointerfaces, 2017-11, Vol.159, p.729-736 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 736 |
---|---|
container_issue | |
container_start_page | 729 |
container_title | Colloids and surfaces, B, Biointerfaces |
container_volume | 159 |
creator | Yoon, Jinho Shin, Jae-Wook Lim, Joungpyo Mohammadniaei, Mohsen Bharate Bapurao, G. Lee, Taek Choi, Jeong-Woo |
description | [Display omitted]
•The nitric oxide biosensor was developed by amine-modified MoS2/GO/Mb hybrid.•For the first time, synthesis of MoS2 accompanying the amine-modification was done.•The hybrid showed the increase of electrochemical signal and amperometric response.•The hybrid showed high selectivity in nitric oxide detection.
Nitric oxide (NO) is one of the most important molecules in living things due to its role as a signaling molecule in influencing pathological and physiological mechanisms including neurotransmission. In this study, the electrochemical biosensor based on the amine-modified molybdenum disulfide nanoparticles (MoS2), graphene oxide (GO) and myoglobin (Mb) hybrid material (amine-modified MoS2/GO/Mb hybrid) is developed to achieve the accurate detection of NO with electrochemical signal improvement. For the first time, the synthesis of MoS2 accompanying the amine-modification of the surface of MoS2 is done to hybridize with GO efficiently through the short linkage. After the amine-modification of MoS2, it is enclosed with GO directly (amine-modified MoS2/GO). Then, Mb which can induce the reduction of NO is immobilized on the amine-modified MoS2/GO to fabricate the amine-modified MoS2/GO/Mb hybrid for NO detection. The prepared hybrid shows the signal improved redox properties relative to the result of the electrode prepared without hybrid. Furthermore, upon addition of NO, the electrode prepared with hybrid shows the improved amperometric response compared with that of the electrode without hybrid. This amine-modified MoS2/GO/Mb hybrid can be used in the development of the biosensor platform accompanying the electrochemical signal improvement and accurate detection of target materials. |
doi_str_mv | 10.1016/j.colsurfb.2017.08.033 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1937528898</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0927776517305489</els_id><sourcerecordid>1937528898</sourcerecordid><originalsourceid>FETCH-LOGICAL-c382t-cbfec2279b0135da9e9616d883b4e8a30b44ab84d626cb5cd4d7a1da809ba303</originalsourceid><addsrcrecordid>eNqFkMtOwzAQRS0EEqXwCyhLNkn9SGxnB6p4SUUs6N7yY9K6SuJip4j-PakCa1YjzdxzpTkI3RJcEEz4YlfY0KZDbExBMREFlgVm7AzNiBQsLxkX52iGaypyIXh1ia5S2mGMaUnEDNnHFuwQg91C561us94P0dssfHsHmfEhQZ9CzIxO4LLQZ7rzPeRdcL7x4-YtfNDFJur9FnqYqEV3DJs2GN9n26OJ3l2ji0a3CW5-5xytnx7Xy5d89f78unxY5ZZJOuTWNGApFbXBhFVO11Bzwp2UzJQgNcOmLLWRpeOUW1NZVzqhidMS12a8sjm6m2r3MXweIA2q88lC2-oewiEpUjNRUSlrOUb5FLUxpBShUfvoOx2PimB1kqp26k-qOklVWKpR6gjeTyCMf3x5iCpZD70F5-PoUbng_6v4AdI4hiw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1937528898</pqid></control><display><type>article</type><title>Electrochemical nitric oxide biosensor based on amine-modified MoS2/graphene oxide/myoglobin hybrid</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Yoon, Jinho ; Shin, Jae-Wook ; Lim, Joungpyo ; Mohammadniaei, Mohsen ; Bharate Bapurao, G. ; Lee, Taek ; Choi, Jeong-Woo</creator><creatorcontrib>Yoon, Jinho ; Shin, Jae-Wook ; Lim, Joungpyo ; Mohammadniaei, Mohsen ; Bharate Bapurao, G. ; Lee, Taek ; Choi, Jeong-Woo</creatorcontrib><description>[Display omitted]
•The nitric oxide biosensor was developed by amine-modified MoS2/GO/Mb hybrid.•For the first time, synthesis of MoS2 accompanying the amine-modification was done.•The hybrid showed the increase of electrochemical signal and amperometric response.•The hybrid showed high selectivity in nitric oxide detection.
Nitric oxide (NO) is one of the most important molecules in living things due to its role as a signaling molecule in influencing pathological and physiological mechanisms including neurotransmission. In this study, the electrochemical biosensor based on the amine-modified molybdenum disulfide nanoparticles (MoS2), graphene oxide (GO) and myoglobin (Mb) hybrid material (amine-modified MoS2/GO/Mb hybrid) is developed to achieve the accurate detection of NO with electrochemical signal improvement. For the first time, the synthesis of MoS2 accompanying the amine-modification of the surface of MoS2 is done to hybridize with GO efficiently through the short linkage. After the amine-modification of MoS2, it is enclosed with GO directly (amine-modified MoS2/GO). Then, Mb which can induce the reduction of NO is immobilized on the amine-modified MoS2/GO to fabricate the amine-modified MoS2/GO/Mb hybrid for NO detection. The prepared hybrid shows the signal improved redox properties relative to the result of the electrode prepared without hybrid. Furthermore, upon addition of NO, the electrode prepared with hybrid shows the improved amperometric response compared with that of the electrode without hybrid. This amine-modified MoS2/GO/Mb hybrid can be used in the development of the biosensor platform accompanying the electrochemical signal improvement and accurate detection of target materials.</description><identifier>ISSN: 0927-7765</identifier><identifier>EISSN: 1873-4367</identifier><identifier>DOI: 10.1016/j.colsurfb.2017.08.033</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Amine-modified MoS2 ; Biosensor ; Graphene oxide ; Hybrid material ; Myoglobin ; Nitric oxide</subject><ispartof>Colloids and surfaces, B, Biointerfaces, 2017-11, Vol.159, p.729-736</ispartof><rights>2017 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c382t-cbfec2279b0135da9e9616d883b4e8a30b44ab84d626cb5cd4d7a1da809ba303</citedby><cites>FETCH-LOGICAL-c382t-cbfec2279b0135da9e9616d883b4e8a30b44ab84d626cb5cd4d7a1da809ba303</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.colsurfb.2017.08.033$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids></links><search><creatorcontrib>Yoon, Jinho</creatorcontrib><creatorcontrib>Shin, Jae-Wook</creatorcontrib><creatorcontrib>Lim, Joungpyo</creatorcontrib><creatorcontrib>Mohammadniaei, Mohsen</creatorcontrib><creatorcontrib>Bharate Bapurao, G.</creatorcontrib><creatorcontrib>Lee, Taek</creatorcontrib><creatorcontrib>Choi, Jeong-Woo</creatorcontrib><title>Electrochemical nitric oxide biosensor based on amine-modified MoS2/graphene oxide/myoglobin hybrid</title><title>Colloids and surfaces, B, Biointerfaces</title><description>[Display omitted]
•The nitric oxide biosensor was developed by amine-modified MoS2/GO/Mb hybrid.•For the first time, synthesis of MoS2 accompanying the amine-modification was done.•The hybrid showed the increase of electrochemical signal and amperometric response.•The hybrid showed high selectivity in nitric oxide detection.
Nitric oxide (NO) is one of the most important molecules in living things due to its role as a signaling molecule in influencing pathological and physiological mechanisms including neurotransmission. In this study, the electrochemical biosensor based on the amine-modified molybdenum disulfide nanoparticles (MoS2), graphene oxide (GO) and myoglobin (Mb) hybrid material (amine-modified MoS2/GO/Mb hybrid) is developed to achieve the accurate detection of NO with electrochemical signal improvement. For the first time, the synthesis of MoS2 accompanying the amine-modification of the surface of MoS2 is done to hybridize with GO efficiently through the short linkage. After the amine-modification of MoS2, it is enclosed with GO directly (amine-modified MoS2/GO). Then, Mb which can induce the reduction of NO is immobilized on the amine-modified MoS2/GO to fabricate the amine-modified MoS2/GO/Mb hybrid for NO detection. The prepared hybrid shows the signal improved redox properties relative to the result of the electrode prepared without hybrid. Furthermore, upon addition of NO, the electrode prepared with hybrid shows the improved amperometric response compared with that of the electrode without hybrid. This amine-modified MoS2/GO/Mb hybrid can be used in the development of the biosensor platform accompanying the electrochemical signal improvement and accurate detection of target materials.</description><subject>Amine-modified MoS2</subject><subject>Biosensor</subject><subject>Graphene oxide</subject><subject>Hybrid material</subject><subject>Myoglobin</subject><subject>Nitric oxide</subject><issn>0927-7765</issn><issn>1873-4367</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqFkMtOwzAQRS0EEqXwCyhLNkn9SGxnB6p4SUUs6N7yY9K6SuJip4j-PakCa1YjzdxzpTkI3RJcEEz4YlfY0KZDbExBMREFlgVm7AzNiBQsLxkX52iGaypyIXh1ia5S2mGMaUnEDNnHFuwQg91C561us94P0dssfHsHmfEhQZ9CzIxO4LLQZ7rzPeRdcL7x4-YtfNDFJur9FnqYqEV3DJs2GN9n26OJ3l2ji0a3CW5-5xytnx7Xy5d89f78unxY5ZZJOuTWNGApFbXBhFVO11Bzwp2UzJQgNcOmLLWRpeOUW1NZVzqhidMS12a8sjm6m2r3MXweIA2q88lC2-oewiEpUjNRUSlrOUb5FLUxpBShUfvoOx2PimB1kqp26k-qOklVWKpR6gjeTyCMf3x5iCpZD70F5-PoUbng_6v4AdI4hiw</recordid><startdate>20171101</startdate><enddate>20171101</enddate><creator>Yoon, Jinho</creator><creator>Shin, Jae-Wook</creator><creator>Lim, Joungpyo</creator><creator>Mohammadniaei, Mohsen</creator><creator>Bharate Bapurao, G.</creator><creator>Lee, Taek</creator><creator>Choi, Jeong-Woo</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20171101</creationdate><title>Electrochemical nitric oxide biosensor based on amine-modified MoS2/graphene oxide/myoglobin hybrid</title><author>Yoon, Jinho ; Shin, Jae-Wook ; Lim, Joungpyo ; Mohammadniaei, Mohsen ; Bharate Bapurao, G. ; Lee, Taek ; Choi, Jeong-Woo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c382t-cbfec2279b0135da9e9616d883b4e8a30b44ab84d626cb5cd4d7a1da809ba303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Amine-modified MoS2</topic><topic>Biosensor</topic><topic>Graphene oxide</topic><topic>Hybrid material</topic><topic>Myoglobin</topic><topic>Nitric oxide</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yoon, Jinho</creatorcontrib><creatorcontrib>Shin, Jae-Wook</creatorcontrib><creatorcontrib>Lim, Joungpyo</creatorcontrib><creatorcontrib>Mohammadniaei, Mohsen</creatorcontrib><creatorcontrib>Bharate Bapurao, G.</creatorcontrib><creatorcontrib>Lee, Taek</creatorcontrib><creatorcontrib>Choi, Jeong-Woo</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Colloids and surfaces, B, Biointerfaces</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yoon, Jinho</au><au>Shin, Jae-Wook</au><au>Lim, Joungpyo</au><au>Mohammadniaei, Mohsen</au><au>Bharate Bapurao, G.</au><au>Lee, Taek</au><au>Choi, Jeong-Woo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrochemical nitric oxide biosensor based on amine-modified MoS2/graphene oxide/myoglobin hybrid</atitle><jtitle>Colloids and surfaces, B, Biointerfaces</jtitle><date>2017-11-01</date><risdate>2017</risdate><volume>159</volume><spage>729</spage><epage>736</epage><pages>729-736</pages><issn>0927-7765</issn><eissn>1873-4367</eissn><abstract>[Display omitted]
•The nitric oxide biosensor was developed by amine-modified MoS2/GO/Mb hybrid.•For the first time, synthesis of MoS2 accompanying the amine-modification was done.•The hybrid showed the increase of electrochemical signal and amperometric response.•The hybrid showed high selectivity in nitric oxide detection.
Nitric oxide (NO) is one of the most important molecules in living things due to its role as a signaling molecule in influencing pathological and physiological mechanisms including neurotransmission. In this study, the electrochemical biosensor based on the amine-modified molybdenum disulfide nanoparticles (MoS2), graphene oxide (GO) and myoglobin (Mb) hybrid material (amine-modified MoS2/GO/Mb hybrid) is developed to achieve the accurate detection of NO with electrochemical signal improvement. For the first time, the synthesis of MoS2 accompanying the amine-modification of the surface of MoS2 is done to hybridize with GO efficiently through the short linkage. After the amine-modification of MoS2, it is enclosed with GO directly (amine-modified MoS2/GO). Then, Mb which can induce the reduction of NO is immobilized on the amine-modified MoS2/GO to fabricate the amine-modified MoS2/GO/Mb hybrid for NO detection. The prepared hybrid shows the signal improved redox properties relative to the result of the electrode prepared without hybrid. Furthermore, upon addition of NO, the electrode prepared with hybrid shows the improved amperometric response compared with that of the electrode without hybrid. This amine-modified MoS2/GO/Mb hybrid can be used in the development of the biosensor platform accompanying the electrochemical signal improvement and accurate detection of target materials.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.colsurfb.2017.08.033</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0927-7765 |
ispartof | Colloids and surfaces, B, Biointerfaces, 2017-11, Vol.159, p.729-736 |
issn | 0927-7765 1873-4367 |
language | eng |
recordid | cdi_proquest_miscellaneous_1937528898 |
source | Elsevier ScienceDirect Journals Complete |
subjects | Amine-modified MoS2 Biosensor Graphene oxide Hybrid material Myoglobin Nitric oxide |
title | Electrochemical nitric oxide biosensor based on amine-modified MoS2/graphene oxide/myoglobin hybrid |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T15%3A12%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrochemical%20nitric%20oxide%20biosensor%20based%20on%20amine-modified%20MoS2/graphene%20oxide/myoglobin%20hybrid&rft.jtitle=Colloids%20and%20surfaces,%20B,%20Biointerfaces&rft.au=Yoon,%20Jinho&rft.date=2017-11-01&rft.volume=159&rft.spage=729&rft.epage=736&rft.pages=729-736&rft.issn=0927-7765&rft.eissn=1873-4367&rft_id=info:doi/10.1016/j.colsurfb.2017.08.033&rft_dat=%3Cproquest_cross%3E1937528898%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1937528898&rft_id=info:pmid/&rft_els_id=S0927776517305489&rfr_iscdi=true |