Evaluation of the Effect of recasting Nickel-chromium Base Metal Alloy on the Metal-ceramic Bond Strength: An in vitro Study
The aim of this study was to evaluate the effect of recasting base metal alloy on the metal-ceramic bond strength. A total of 60 test samples were prepared from new and recast nickel-chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A...
Gespeichert in:
Veröffentlicht in: | The journal of contemporary dental practice 2017-09, Vol.18 (9), p.837-841 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 841 |
---|---|
container_issue | 9 |
container_start_page | 837 |
container_title | The journal of contemporary dental practice |
container_volume | 18 |
creator | Meenakshi, T Bharathi, Munagapati Komala, Jayasree |
description | The aim of this study was to evaluate the effect of recasting base metal alloy on the metal-ceramic bond strength.
A total of 60 test samples were prepared from new and recast nickel-chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A2, A3, A4, and A5 were prepared from 50% new alloy and 50% casting remnants (sprue and buttons) of the previous group by weight. All these samples were coated with ceramic (IPS d.SIGN and Ivoclar-Vivadent), and samples were then subjected to three-point bending test to evaluate metal-ceramic bond strength.
The values were analyzed using one-way analysis of variance and Tukey's post hoc test. The mean bond strength of group A0 was higher than that of groups A1, A2, A3, A4, and A5.
Metal-ceramic bond strength decreased significantly with multiple recastings.
Bond strength between metal and ceramic is a crucial factor for the clinical performance of metal-ceramic restorations. Recasting of alloys may affect the metal oxide layer composition and thickness of metal-ceramic interface, and thereby the metal-ceramic bond. |
doi_str_mv | 10.5005/jp-journals-10024-2136 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1936266560</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1936266560</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2746-7105d201f0b1acfa9db32ec9a0e1b3d346b42ab66e7724610b9932b4bf968adc3</originalsourceid><addsrcrecordid>eNpNkMlOwzAURS0EYij8AvKSjcFD4jTsWlQGiWEBrC3beaEuSVxsp1IlPp6UAmL1Bt37hoPQKaPnOaX5xWJJFr4PnW4iYZTyjHAm5A46ZDmXRBSM7f7LD9BRjItBJnhB99EBH4-LTObsEH3OVrrpdXK-w77GaQ54Vtdg06YKYHVMrnvDj86-Q0PsPPjW9S2e6gj4AZJu8KRp_BoP9o33u0UsBN06i6e-q_BzCtC9pfklnnTYdXjlUvBDt6_Wx2ivHh6Ak584Qq_Xs5erW3L_dHN3Nbknlg9nkoLRvOKU1dQwbWtdVkZwsKWmwIyoRCZNxrWREoqCZ5JRU5aCm8zUpRzryooROtvOXQb_0UNMqnXRQtPoDnwfFSuF5FLmkg5SuZXa4GMMUKtlcK0Oa8Wo2pBXi6X6Ja--yasN-cF4-rOjNy1Uf7Zf1OILDAuDBg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1936266560</pqid></control><display><type>article</type><title>Evaluation of the Effect of recasting Nickel-chromium Base Metal Alloy on the Metal-ceramic Bond Strength: An in vitro Study</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Alma/SFX Local Collection</source><creator>Meenakshi, T ; Bharathi, Munagapati ; Komala, Jayasree</creator><creatorcontrib>Meenakshi, T ; Bharathi, Munagapati ; Komala, Jayasree</creatorcontrib><description>The aim of this study was to evaluate the effect of recasting base metal alloy on the metal-ceramic bond strength.
A total of 60 test samples were prepared from new and recast nickel-chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A2, A3, A4, and A5 were prepared from 50% new alloy and 50% casting remnants (sprue and buttons) of the previous group by weight. All these samples were coated with ceramic (IPS d.SIGN and Ivoclar-Vivadent), and samples were then subjected to three-point bending test to evaluate metal-ceramic bond strength.
The values were analyzed using one-way analysis of variance and Tukey's post hoc test. The mean bond strength of group A0 was higher than that of groups A1, A2, A3, A4, and A5.
Metal-ceramic bond strength decreased significantly with multiple recastings.
Bond strength between metal and ceramic is a crucial factor for the clinical performance of metal-ceramic restorations. Recasting of alloys may affect the metal oxide layer composition and thickness of metal-ceramic interface, and thereby the metal-ceramic bond.</description><identifier>ISSN: 1526-3711</identifier><identifier>EISSN: 1526-3711</identifier><identifier>DOI: 10.5005/jp-journals-10024-2136</identifier><identifier>PMID: 28874651</identifier><language>eng</language><publisher>India</publisher><subject>Chromium Alloys ; Dental Bonding ; Dental Stress Analysis ; Dentistry ; Materials Testing ; Metal Ceramic Alloys</subject><ispartof>The journal of contemporary dental practice, 2017-09, Vol.18 (9), p.837-841</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2746-7105d201f0b1acfa9db32ec9a0e1b3d346b42ab66e7724610b9932b4bf968adc3</citedby><cites>FETCH-LOGICAL-c2746-7105d201f0b1acfa9db32ec9a0e1b3d346b42ab66e7724610b9932b4bf968adc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28874651$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Meenakshi, T</creatorcontrib><creatorcontrib>Bharathi, Munagapati</creatorcontrib><creatorcontrib>Komala, Jayasree</creatorcontrib><title>Evaluation of the Effect of recasting Nickel-chromium Base Metal Alloy on the Metal-ceramic Bond Strength: An in vitro Study</title><title>The journal of contemporary dental practice</title><addtitle>J Contemp Dent Pract</addtitle><description>The aim of this study was to evaluate the effect of recasting base metal alloy on the metal-ceramic bond strength.
A total of 60 test samples were prepared from new and recast nickel-chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A2, A3, A4, and A5 were prepared from 50% new alloy and 50% casting remnants (sprue and buttons) of the previous group by weight. All these samples were coated with ceramic (IPS d.SIGN and Ivoclar-Vivadent), and samples were then subjected to three-point bending test to evaluate metal-ceramic bond strength.
The values were analyzed using one-way analysis of variance and Tukey's post hoc test. The mean bond strength of group A0 was higher than that of groups A1, A2, A3, A4, and A5.
Metal-ceramic bond strength decreased significantly with multiple recastings.
Bond strength between metal and ceramic is a crucial factor for the clinical performance of metal-ceramic restorations. Recasting of alloys may affect the metal oxide layer composition and thickness of metal-ceramic interface, and thereby the metal-ceramic bond.</description><subject>Chromium Alloys</subject><subject>Dental Bonding</subject><subject>Dental Stress Analysis</subject><subject>Dentistry</subject><subject>Materials Testing</subject><subject>Metal Ceramic Alloys</subject><issn>1526-3711</issn><issn>1526-3711</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkMlOwzAURS0EYij8AvKSjcFD4jTsWlQGiWEBrC3beaEuSVxsp1IlPp6UAmL1Bt37hoPQKaPnOaX5xWJJFr4PnW4iYZTyjHAm5A46ZDmXRBSM7f7LD9BRjItBJnhB99EBH4-LTObsEH3OVrrpdXK-w77GaQ54Vtdg06YKYHVMrnvDj86-Q0PsPPjW9S2e6gj4AZJu8KRp_BoP9o33u0UsBN06i6e-q_BzCtC9pfklnnTYdXjlUvBDt6_Wx2ivHh6Ak584Qq_Xs5erW3L_dHN3Nbknlg9nkoLRvOKU1dQwbWtdVkZwsKWmwIyoRCZNxrWREoqCZ5JRU5aCm8zUpRzryooROtvOXQb_0UNMqnXRQtPoDnwfFSuF5FLmkg5SuZXa4GMMUKtlcK0Oa8Wo2pBXi6X6Ja--yasN-cF4-rOjNy1Uf7Zf1OILDAuDBg</recordid><startdate>20170901</startdate><enddate>20170901</enddate><creator>Meenakshi, T</creator><creator>Bharathi, Munagapati</creator><creator>Komala, Jayasree</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170901</creationdate><title>Evaluation of the Effect of recasting Nickel-chromium Base Metal Alloy on the Metal-ceramic Bond Strength: An in vitro Study</title><author>Meenakshi, T ; Bharathi, Munagapati ; Komala, Jayasree</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2746-7105d201f0b1acfa9db32ec9a0e1b3d346b42ab66e7724610b9932b4bf968adc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Chromium Alloys</topic><topic>Dental Bonding</topic><topic>Dental Stress Analysis</topic><topic>Dentistry</topic><topic>Materials Testing</topic><topic>Metal Ceramic Alloys</topic><toplevel>online_resources</toplevel><creatorcontrib>Meenakshi, T</creatorcontrib><creatorcontrib>Bharathi, Munagapati</creatorcontrib><creatorcontrib>Komala, Jayasree</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The journal of contemporary dental practice</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Meenakshi, T</au><au>Bharathi, Munagapati</au><au>Komala, Jayasree</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the Effect of recasting Nickel-chromium Base Metal Alloy on the Metal-ceramic Bond Strength: An in vitro Study</atitle><jtitle>The journal of contemporary dental practice</jtitle><addtitle>J Contemp Dent Pract</addtitle><date>2017-09-01</date><risdate>2017</risdate><volume>18</volume><issue>9</issue><spage>837</spage><epage>841</epage><pages>837-841</pages><issn>1526-3711</issn><eissn>1526-3711</eissn><abstract>The aim of this study was to evaluate the effect of recasting base metal alloy on the metal-ceramic bond strength.
A total of 60 test samples were prepared from new and recast nickel-chromium alloy and divided into six groups. In group A0, test samples were prepared from 100% new alloy. Groups A1, A2, A3, A4, and A5 were prepared from 50% new alloy and 50% casting remnants (sprue and buttons) of the previous group by weight. All these samples were coated with ceramic (IPS d.SIGN and Ivoclar-Vivadent), and samples were then subjected to three-point bending test to evaluate metal-ceramic bond strength.
The values were analyzed using one-way analysis of variance and Tukey's post hoc test. The mean bond strength of group A0 was higher than that of groups A1, A2, A3, A4, and A5.
Metal-ceramic bond strength decreased significantly with multiple recastings.
Bond strength between metal and ceramic is a crucial factor for the clinical performance of metal-ceramic restorations. Recasting of alloys may affect the metal oxide layer composition and thickness of metal-ceramic interface, and thereby the metal-ceramic bond.</abstract><cop>India</cop><pmid>28874651</pmid><doi>10.5005/jp-journals-10024-2136</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1526-3711 |
ispartof | The journal of contemporary dental practice, 2017-09, Vol.18 (9), p.837-841 |
issn | 1526-3711 1526-3711 |
language | eng |
recordid | cdi_proquest_miscellaneous_1936266560 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Alma/SFX Local Collection |
subjects | Chromium Alloys Dental Bonding Dental Stress Analysis Dentistry Materials Testing Metal Ceramic Alloys |
title | Evaluation of the Effect of recasting Nickel-chromium Base Metal Alloy on the Metal-ceramic Bond Strength: An in vitro Study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T16%3A41%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20Effect%20of%20recasting%20Nickel-chromium%20Base%20Metal%20Alloy%20on%20the%20Metal-ceramic%20Bond%20Strength:%20An%20in%20vitro%20Study&rft.jtitle=The%20journal%20of%20contemporary%20dental%20practice&rft.au=Meenakshi,%20T&rft.date=2017-09-01&rft.volume=18&rft.issue=9&rft.spage=837&rft.epage=841&rft.pages=837-841&rft.issn=1526-3711&rft.eissn=1526-3711&rft_id=info:doi/10.5005/jp-journals-10024-2136&rft_dat=%3Cproquest_cross%3E1936266560%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1936266560&rft_id=info:pmid/28874651&rfr_iscdi=true |