Morbidity and mortality in children undergoing bronchoscopy for foreign body removal

Objectives/Hypothesis Analyze morbidity and mortality among children undergoing bronchoscopy for foreign body removal. Study Design Multicenter retrospective review using the American College of Surgeons Pediatric National Surgical Quality Improvement Program from 2014 and 2015. Methods Patients wer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Laryngoscope 2018-05, Vol.128 (5), p.1226-1229
Hauptverfasser: Roberts, Christopher A., Carr, Michele M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1229
container_issue 5
container_start_page 1226
container_title The Laryngoscope
container_volume 128
creator Roberts, Christopher A.
Carr, Michele M.
description Objectives/Hypothesis Analyze morbidity and mortality among children undergoing bronchoscopy for foreign body removal. Study Design Multicenter retrospective review using the American College of Surgeons Pediatric National Surgical Quality Improvement Program from 2014 and 2015. Methods Patients were identified using Current Procedural Terminology code 31635. Demographics, time to surgery, operative times, hospitalization time, and complications were collected. Multivariate logistic regression was used to identify predictive factors for major adverse events. Results Three hundred thirty‐four patients were included (mean age 3.7 years, 59.0% male). Preoperative sepsis syndrome was present in 5.7% of patients and 8.1% had asthma. Of the patients, 5.1% percent of patients had a tracheostomy. Bronchoscopy was performed by an otolaryngologist (65.4%) or a pediatric surgeon (33.1%). Mean operative time was 27.4 minutes, whereas mean total operating room time was 54.6 minutes. Airway foreign bodies were located in 269 patients (80.5%), with 62.5% being located in the mainstem bronchus. Operative time was longer when foreign bodies were in the mainstem bronchus or distal to it. Mean time to surgery from admission was 0 days, and mean duration of hospitalization was 1 day. One patient (0.3%) required reoperation for respiratory reasons, and three (0.9%) required readmission for related reasons. No patients remained hospitalized at 30 days. Two (0.6%) had a postoperative pneumonia, and two (0.6%) required reintubation. One patient death (0.3%) occurred within 2 weeks of bronchoscopy. No significant differences were identified in operative time, time to surgery, or hospitalization time based on age, gender, presence of a tracheostomy, or surgical specialty. Conclusions Bronchoscopy for identification and removal of airway foreign bodies had minimal morbidity in this group. Level of Evidence 2b. Laryngoscope, 128:1226–1229, 2018
doi_str_mv 10.1002/lary.26817
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1930490422</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1930490422</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3577-bf8635b65f36495ea10c13d664b521aaac2a01a482f9884bb889ba6d622e62d13</originalsourceid><addsrcrecordid>eNp9kE1LwzAYgIMoOj8u_gApeBGhmo8mTY9j-AUTQSboKSRNumW0yUxWpf_e1k0PHjyEl_A-PLw8AJwieIUgxNe1DN0VZhzlO2CEKEFpVhR0F4z6JUk5xa8H4DDGJYQoJxTugwPMOaIMZyMwe_RBWW3XXSKdThof1rIeftYl5cLWOhiXtE6bMPfWzRMVvCsXPpZ-1SWVD8Mzdu4S5XWXBNP4D1kfg71K1tGcbOcReLm9mU3u0-nT3cNkPE1LQvM8VRVnhCpGK8KyghqJYImIZixTFCMpZYklRDLjuCo4z5TivFCSaYaxYVgjcgQuNt5V8O-tiWvR2FiaupbO-DYKVBCYFTDDuEfP_6BL3wbXXycwxDktYA4H6nJDlcHHGEwlVsE2fV6BoBhai6G1-G7dw2dbZasao3_Rn7g9gDbAp61N949KTMfPbxvpF7R9iZs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2027590702</pqid></control><display><type>article</type><title>Morbidity and mortality in children undergoing bronchoscopy for foreign body removal</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Roberts, Christopher A. ; Carr, Michele M.</creator><creatorcontrib>Roberts, Christopher A. ; Carr, Michele M.</creatorcontrib><description>Objectives/Hypothesis Analyze morbidity and mortality among children undergoing bronchoscopy for foreign body removal. Study Design Multicenter retrospective review using the American College of Surgeons Pediatric National Surgical Quality Improvement Program from 2014 and 2015. Methods Patients were identified using Current Procedural Terminology code 31635. Demographics, time to surgery, operative times, hospitalization time, and complications were collected. Multivariate logistic regression was used to identify predictive factors for major adverse events. Results Three hundred thirty‐four patients were included (mean age 3.7 years, 59.0% male). Preoperative sepsis syndrome was present in 5.7% of patients and 8.1% had asthma. Of the patients, 5.1% percent of patients had a tracheostomy. Bronchoscopy was performed by an otolaryngologist (65.4%) or a pediatric surgeon (33.1%). Mean operative time was 27.4 minutes, whereas mean total operating room time was 54.6 minutes. Airway foreign bodies were located in 269 patients (80.5%), with 62.5% being located in the mainstem bronchus. Operative time was longer when foreign bodies were in the mainstem bronchus or distal to it. Mean time to surgery from admission was 0 days, and mean duration of hospitalization was 1 day. One patient (0.3%) required reoperation for respiratory reasons, and three (0.9%) required readmission for related reasons. No patients remained hospitalized at 30 days. Two (0.6%) had a postoperative pneumonia, and two (0.6%) required reintubation. One patient death (0.3%) occurred within 2 weeks of bronchoscopy. No significant differences were identified in operative time, time to surgery, or hospitalization time based on age, gender, presence of a tracheostomy, or surgical specialty. Conclusions Bronchoscopy for identification and removal of airway foreign bodies had minimal morbidity in this group. Level of Evidence 2b. Laryngoscope, 128:1226–1229, 2018</description><identifier>ISSN: 0023-852X</identifier><identifier>EISSN: 1531-4995</identifier><identifier>DOI: 10.1002/lary.26817</identifier><identifier>PMID: 28815624</identifier><language>eng</language><publisher>United States: Wiley Subscription Services, Inc</publisher><subject>bronchoscopy ; foreign body ; Morbidity ; Mortality ; Ostomy ; Patients ; Pediatric airway ; Pediatrics ; statistics ; Surgery ; Terminology</subject><ispartof>The Laryngoscope, 2018-05, Vol.128 (5), p.1226-1229</ispartof><rights>2017 The American Laryngological, Rhinological and Otological Society, Inc.</rights><rights>2018 The American Laryngological, Rhinological and Otological Society, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3577-bf8635b65f36495ea10c13d664b521aaac2a01a482f9884bb889ba6d622e62d13</citedby><cites>FETCH-LOGICAL-c3577-bf8635b65f36495ea10c13d664b521aaac2a01a482f9884bb889ba6d622e62d13</cites><orcidid>0000-0002-7406-4467</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Flary.26817$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Flary.26817$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28815624$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Roberts, Christopher A.</creatorcontrib><creatorcontrib>Carr, Michele M.</creatorcontrib><title>Morbidity and mortality in children undergoing bronchoscopy for foreign body removal</title><title>The Laryngoscope</title><addtitle>Laryngoscope</addtitle><description>Objectives/Hypothesis Analyze morbidity and mortality among children undergoing bronchoscopy for foreign body removal. Study Design Multicenter retrospective review using the American College of Surgeons Pediatric National Surgical Quality Improvement Program from 2014 and 2015. Methods Patients were identified using Current Procedural Terminology code 31635. Demographics, time to surgery, operative times, hospitalization time, and complications were collected. Multivariate logistic regression was used to identify predictive factors for major adverse events. Results Three hundred thirty‐four patients were included (mean age 3.7 years, 59.0% male). Preoperative sepsis syndrome was present in 5.7% of patients and 8.1% had asthma. Of the patients, 5.1% percent of patients had a tracheostomy. Bronchoscopy was performed by an otolaryngologist (65.4%) or a pediatric surgeon (33.1%). Mean operative time was 27.4 minutes, whereas mean total operating room time was 54.6 minutes. Airway foreign bodies were located in 269 patients (80.5%), with 62.5% being located in the mainstem bronchus. Operative time was longer when foreign bodies were in the mainstem bronchus or distal to it. Mean time to surgery from admission was 0 days, and mean duration of hospitalization was 1 day. One patient (0.3%) required reoperation for respiratory reasons, and three (0.9%) required readmission for related reasons. No patients remained hospitalized at 30 days. Two (0.6%) had a postoperative pneumonia, and two (0.6%) required reintubation. One patient death (0.3%) occurred within 2 weeks of bronchoscopy. No significant differences were identified in operative time, time to surgery, or hospitalization time based on age, gender, presence of a tracheostomy, or surgical specialty. Conclusions Bronchoscopy for identification and removal of airway foreign bodies had minimal morbidity in this group. Level of Evidence 2b. Laryngoscope, 128:1226–1229, 2018</description><subject>bronchoscopy</subject><subject>foreign body</subject><subject>Morbidity</subject><subject>Mortality</subject><subject>Ostomy</subject><subject>Patients</subject><subject>Pediatric airway</subject><subject>Pediatrics</subject><subject>statistics</subject><subject>Surgery</subject><subject>Terminology</subject><issn>0023-852X</issn><issn>1531-4995</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LwzAYgIMoOj8u_gApeBGhmo8mTY9j-AUTQSboKSRNumW0yUxWpf_e1k0PHjyEl_A-PLw8AJwieIUgxNe1DN0VZhzlO2CEKEFpVhR0F4z6JUk5xa8H4DDGJYQoJxTugwPMOaIMZyMwe_RBWW3XXSKdThof1rIeftYl5cLWOhiXtE6bMPfWzRMVvCsXPpZ-1SWVD8Mzdu4S5XWXBNP4D1kfg71K1tGcbOcReLm9mU3u0-nT3cNkPE1LQvM8VRVnhCpGK8KyghqJYImIZixTFCMpZYklRDLjuCo4z5TivFCSaYaxYVgjcgQuNt5V8O-tiWvR2FiaupbO-DYKVBCYFTDDuEfP_6BL3wbXXycwxDktYA4H6nJDlcHHGEwlVsE2fV6BoBhai6G1-G7dw2dbZasao3_Rn7g9gDbAp61N949KTMfPbxvpF7R9iZs</recordid><startdate>201805</startdate><enddate>201805</enddate><creator>Roberts, Christopher A.</creator><creator>Carr, Michele M.</creator><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-7406-4467</orcidid></search><sort><creationdate>201805</creationdate><title>Morbidity and mortality in children undergoing bronchoscopy for foreign body removal</title><author>Roberts, Christopher A. ; Carr, Michele M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3577-bf8635b65f36495ea10c13d664b521aaac2a01a482f9884bb889ba6d622e62d13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>bronchoscopy</topic><topic>foreign body</topic><topic>Morbidity</topic><topic>Mortality</topic><topic>Ostomy</topic><topic>Patients</topic><topic>Pediatric airway</topic><topic>Pediatrics</topic><topic>statistics</topic><topic>Surgery</topic><topic>Terminology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Roberts, Christopher A.</creatorcontrib><creatorcontrib>Carr, Michele M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>MEDLINE - Academic</collection><jtitle>The Laryngoscope</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Roberts, Christopher A.</au><au>Carr, Michele M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Morbidity and mortality in children undergoing bronchoscopy for foreign body removal</atitle><jtitle>The Laryngoscope</jtitle><addtitle>Laryngoscope</addtitle><date>2018-05</date><risdate>2018</risdate><volume>128</volume><issue>5</issue><spage>1226</spage><epage>1229</epage><pages>1226-1229</pages><issn>0023-852X</issn><eissn>1531-4995</eissn><abstract>Objectives/Hypothesis Analyze morbidity and mortality among children undergoing bronchoscopy for foreign body removal. Study Design Multicenter retrospective review using the American College of Surgeons Pediatric National Surgical Quality Improvement Program from 2014 and 2015. Methods Patients were identified using Current Procedural Terminology code 31635. Demographics, time to surgery, operative times, hospitalization time, and complications were collected. Multivariate logistic regression was used to identify predictive factors for major adverse events. Results Three hundred thirty‐four patients were included (mean age 3.7 years, 59.0% male). Preoperative sepsis syndrome was present in 5.7% of patients and 8.1% had asthma. Of the patients, 5.1% percent of patients had a tracheostomy. Bronchoscopy was performed by an otolaryngologist (65.4%) or a pediatric surgeon (33.1%). Mean operative time was 27.4 minutes, whereas mean total operating room time was 54.6 minutes. Airway foreign bodies were located in 269 patients (80.5%), with 62.5% being located in the mainstem bronchus. Operative time was longer when foreign bodies were in the mainstem bronchus or distal to it. Mean time to surgery from admission was 0 days, and mean duration of hospitalization was 1 day. One patient (0.3%) required reoperation for respiratory reasons, and three (0.9%) required readmission for related reasons. No patients remained hospitalized at 30 days. Two (0.6%) had a postoperative pneumonia, and two (0.6%) required reintubation. One patient death (0.3%) occurred within 2 weeks of bronchoscopy. No significant differences were identified in operative time, time to surgery, or hospitalization time based on age, gender, presence of a tracheostomy, or surgical specialty. Conclusions Bronchoscopy for identification and removal of airway foreign bodies had minimal morbidity in this group. Level of Evidence 2b. Laryngoscope, 128:1226–1229, 2018</abstract><cop>United States</cop><pub>Wiley Subscription Services, Inc</pub><pmid>28815624</pmid><doi>10.1002/lary.26817</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0002-7406-4467</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0023-852X
ispartof The Laryngoscope, 2018-05, Vol.128 (5), p.1226-1229
issn 0023-852X
1531-4995
language eng
recordid cdi_proquest_miscellaneous_1930490422
source Wiley Online Library Journals Frontfile Complete
subjects bronchoscopy
foreign body
Morbidity
Mortality
Ostomy
Patients
Pediatric airway
Pediatrics
statistics
Surgery
Terminology
title Morbidity and mortality in children undergoing bronchoscopy for foreign body removal
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T16%3A15%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Morbidity%20and%20mortality%20in%20children%20undergoing%20bronchoscopy%20for%20foreign%20body%20removal&rft.jtitle=The%20Laryngoscope&rft.au=Roberts,%20Christopher%20A.&rft.date=2018-05&rft.volume=128&rft.issue=5&rft.spage=1226&rft.epage=1229&rft.pages=1226-1229&rft.issn=0023-852X&rft.eissn=1531-4995&rft_id=info:doi/10.1002/lary.26817&rft_dat=%3Cproquest_cross%3E1930490422%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2027590702&rft_id=info:pmid/28815624&rfr_iscdi=true