Please Don't Move—Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features
Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans...
Gespeichert in:
Veröffentlicht in: | Journal of clinical densitometry 2018-04, Vol.21 (2), p.260-268 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 268 |
---|---|
container_issue | 2 |
container_start_page | 260 |
container_title | Journal of clinical densitometry |
container_volume | 21 |
creator | Rantalainen, Timo Chivers, Paola Beck, Belinda R. Robertson, Sam Hart, Nicolas H. Nimphius, Sophia Weeks, Benjamin K. McIntyre, Fleur Hands, Beth Siafarikas, Aris |
description | Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01–0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans. |
doi_str_mv | 10.1016/j.jocd.2017.07.002 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1928516259</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1094695017300227</els_id><sourcerecordid>1928516259</sourcerecordid><originalsourceid>FETCH-LOGICAL-c400t-c7366ed54cb648f10646d1ddffd2da519f7957ed0e0f7810f6269d9492f1c8533</originalsourceid><addsrcrecordid>eNp9kNFqFDEUhoMotlZfwAvJnd7MNslOMhPwpmy7tVBpxe11SJOTNsvMZEwyi70Q-hA-oU9ihq1eFn44h8P3_3B-hN5TsqCEiuPtYhuMXTBCmwUpIuwFOqScy4o0dfOy7ETWlZCcHKA3KW0LQGnbvEYHrG0JpaI9RL-uO9AJ8GkYPmb8Nezgz-Pvs53uJp39cFcu2YcBn8TsnTYZr2Po8TVEP95D1B3-Nukh-1zgHeBV6Mcpg8Wb0Ie7qMf7B_zd6CHhmzSHbeBnnmbXGnRZIL1Fr5zuErx7mkfoZn22WX2pLq_OL1Ynl5WpCcmVaZZCgOW1uRV16ygRtbDUWucss5pT6RrJG7AEiGtaSpxgQlpZS-aoaflyeYQ-7XPHGH5MkLLqfTLQdXqAMCVFJWs5FYzLgrI9amJIKYJTY_S9jg-KEjXXrrZqrl3NtStSRFgxfXjKn257sP8t_3ouwOc9AOXLnYeokvEwGLA-gsnKBv9c_l-yrpZP</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1928516259</pqid></control><display><type>article</type><title>Please Don't Move—Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features</title><source>Access via ScienceDirect (Elsevier)</source><creator>Rantalainen, Timo ; Chivers, Paola ; Beck, Belinda R. ; Robertson, Sam ; Hart, Nicolas H. ; Nimphius, Sophia ; Weeks, Benjamin K. ; McIntyre, Fleur ; Hands, Beth ; Siafarikas, Aris</creator><creatorcontrib>Rantalainen, Timo ; Chivers, Paola ; Beck, Belinda R. ; Robertson, Sam ; Hart, Nicolas H. ; Nimphius, Sophia ; Weeks, Benjamin K. ; McIntyre, Fleur ; Hands, Beth ; Siafarikas, Aris</creatorcontrib><description>Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01–0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans.</description><identifier>ISSN: 1094-6950</identifier><identifier>EISSN: 1559-0747</identifier><identifier>DOI: 10.1016/j.jocd.2017.07.002</identifier><identifier>PMID: 28801168</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Bone QCT ; machine learning ; morphology ; precision ; repeatability</subject><ispartof>Journal of clinical densitometry, 2018-04, Vol.21 (2), p.260-268</ispartof><rights>2017 The International Society for Clinical Densitometry</rights><rights>Copyright © 2017 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c400t-c7366ed54cb648f10646d1ddffd2da519f7957ed0e0f7810f6269d9492f1c8533</citedby><cites>FETCH-LOGICAL-c400t-c7366ed54cb648f10646d1ddffd2da519f7957ed0e0f7810f6269d9492f1c8533</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jocd.2017.07.002$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,782,786,3554,27933,27934,46004</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28801168$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rantalainen, Timo</creatorcontrib><creatorcontrib>Chivers, Paola</creatorcontrib><creatorcontrib>Beck, Belinda R.</creatorcontrib><creatorcontrib>Robertson, Sam</creatorcontrib><creatorcontrib>Hart, Nicolas H.</creatorcontrib><creatorcontrib>Nimphius, Sophia</creatorcontrib><creatorcontrib>Weeks, Benjamin K.</creatorcontrib><creatorcontrib>McIntyre, Fleur</creatorcontrib><creatorcontrib>Hands, Beth</creatorcontrib><creatorcontrib>Siafarikas, Aris</creatorcontrib><title>Please Don't Move—Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features</title><title>Journal of clinical densitometry</title><addtitle>J Clin Densitom</addtitle><description>Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01–0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans.</description><subject>Bone QCT</subject><subject>machine learning</subject><subject>morphology</subject><subject>precision</subject><subject>repeatability</subject><issn>1094-6950</issn><issn>1559-0747</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kNFqFDEUhoMotlZfwAvJnd7MNslOMhPwpmy7tVBpxe11SJOTNsvMZEwyi70Q-hA-oU9ihq1eFn44h8P3_3B-hN5TsqCEiuPtYhuMXTBCmwUpIuwFOqScy4o0dfOy7ETWlZCcHKA3KW0LQGnbvEYHrG0JpaI9RL-uO9AJ8GkYPmb8Nezgz-Pvs53uJp39cFcu2YcBn8TsnTYZr2Po8TVEP95D1B3-Nukh-1zgHeBV6Mcpg8Wb0Ie7qMf7B_zd6CHhmzSHbeBnnmbXGnRZIL1Fr5zuErx7mkfoZn22WX2pLq_OL1Ynl5WpCcmVaZZCgOW1uRV16ygRtbDUWucss5pT6RrJG7AEiGtaSpxgQlpZS-aoaflyeYQ-7XPHGH5MkLLqfTLQdXqAMCVFJWs5FYzLgrI9amJIKYJTY_S9jg-KEjXXrrZqrl3NtStSRFgxfXjKn257sP8t_3ouwOc9AOXLnYeokvEwGLA-gsnKBv9c_l-yrpZP</recordid><startdate>201804</startdate><enddate>201804</enddate><creator>Rantalainen, Timo</creator><creator>Chivers, Paola</creator><creator>Beck, Belinda R.</creator><creator>Robertson, Sam</creator><creator>Hart, Nicolas H.</creator><creator>Nimphius, Sophia</creator><creator>Weeks, Benjamin K.</creator><creator>McIntyre, Fleur</creator><creator>Hands, Beth</creator><creator>Siafarikas, Aris</creator><general>Elsevier Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201804</creationdate><title>Please Don't Move—Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features</title><author>Rantalainen, Timo ; Chivers, Paola ; Beck, Belinda R. ; Robertson, Sam ; Hart, Nicolas H. ; Nimphius, Sophia ; Weeks, Benjamin K. ; McIntyre, Fleur ; Hands, Beth ; Siafarikas, Aris</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c400t-c7366ed54cb648f10646d1ddffd2da519f7957ed0e0f7810f6269d9492f1c8533</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Bone QCT</topic><topic>machine learning</topic><topic>morphology</topic><topic>precision</topic><topic>repeatability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rantalainen, Timo</creatorcontrib><creatorcontrib>Chivers, Paola</creatorcontrib><creatorcontrib>Beck, Belinda R.</creatorcontrib><creatorcontrib>Robertson, Sam</creatorcontrib><creatorcontrib>Hart, Nicolas H.</creatorcontrib><creatorcontrib>Nimphius, Sophia</creatorcontrib><creatorcontrib>Weeks, Benjamin K.</creatorcontrib><creatorcontrib>McIntyre, Fleur</creatorcontrib><creatorcontrib>Hands, Beth</creatorcontrib><creatorcontrib>Siafarikas, Aris</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of clinical densitometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rantalainen, Timo</au><au>Chivers, Paola</au><au>Beck, Belinda R.</au><au>Robertson, Sam</au><au>Hart, Nicolas H.</au><au>Nimphius, Sophia</au><au>Weeks, Benjamin K.</au><au>McIntyre, Fleur</au><au>Hands, Beth</au><au>Siafarikas, Aris</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Please Don't Move—Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features</atitle><jtitle>Journal of clinical densitometry</jtitle><addtitle>J Clin Densitom</addtitle><date>2018-04</date><risdate>2018</risdate><volume>21</volume><issue>2</issue><spage>260</spage><epage>268</epage><pages>260-268</pages><issn>1094-6950</issn><eissn>1559-0747</eissn><abstract>Most imaging methods, including peripheral quantitative computed tomography (pQCT), are susceptible to motion artifacts particularly in fidgety pediatric populations. Methods currently used to address motion artifact include manual screening (visual inspection) and objective assessments of the scans. However, previously reported objective methods either cannot be applied on the reconstructed image or have not been tested for distal bone sites. Therefore, the purpose of the present study was to develop and validate motion artifact classifiers to quantify motion artifact in pQCT scans. Whether textural features could provide adequate motion artifact classification performance in 2 adolescent datasets with pQCT scans from tibial and radial diaphyses and epiphyses was tested. The first dataset was split into training (66% of sample) and validation (33% of sample) datasets. Visual classification was used as the ground truth. Moderate to substantial classification performance (J48 classifier, kappa coefficients from 0.57 to 0.80) was observed in the validation dataset with the novel texture-based classifier. In applying the same classifier to the second cross-sectional dataset, a slight-to-fair (κ = 0.01–0.39) classification performance was observed. Overall, this novel textural analysis-based classifier provided a moderate-to-substantial classification of motion artifact when the classifier was specifically trained for the measurement device and population. Classification based on textural features may be used to prescreen obviously acceptable and unacceptable scans, with a subsequent human-operated visual classification of any remaining scans.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>28801168</pmid><doi>10.1016/j.jocd.2017.07.002</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-6950 |
ispartof | Journal of clinical densitometry, 2018-04, Vol.21 (2), p.260-268 |
issn | 1094-6950 1559-0747 |
language | eng |
recordid | cdi_proquest_miscellaneous_1928516259 |
source | Access via ScienceDirect (Elsevier) |
subjects | Bone QCT machine learning morphology precision repeatability |
title | Please Don't Move—Evaluating Motion Artifact From Peripheral Quantitative Computed Tomography Scans Using Textural Features |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-02T20%3A51%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Please%20Don't%20Move%E2%80%94Evaluating%20Motion%20Artifact%20From%20Peripheral%20Quantitative%20Computed%20Tomography%20Scans%20Using%20Textural%20Features&rft.jtitle=Journal%20of%20clinical%20densitometry&rft.au=Rantalainen,%20Timo&rft.date=2018-04&rft.volume=21&rft.issue=2&rft.spage=260&rft.epage=268&rft.pages=260-268&rft.issn=1094-6950&rft.eissn=1559-0747&rft_id=info:doi/10.1016/j.jocd.2017.07.002&rft_dat=%3Cproquest_cross%3E1928516259%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1928516259&rft_id=info:pmid/28801168&rft_els_id=S1094695017300227&rfr_iscdi=true |