A continuous usability evaluation of an electronic medication administration record application

Rationale, aims, and objectives The complexity of an electronic medication administration record (eMAR) has been underestimated by most designers in the past. Usability issues, such as poorly designed user application flow in eMAR, are therefore of vital importance, since they can have a negative im...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of evaluation in clinical practice 2017-12, Vol.23 (6), p.1395-1400
Hauptverfasser: Vicente Oliveros, Noelia, Gramage Caro, Teresa, Pérez Menéndez‐Conde, Covadonga, Álvarez‐Diaz, Ana María, Martín‐Aragón Álvarez, Sagrario, Bermejo Vicedo, Teresa, Delgado Silveira, Eva
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Rationale, aims, and objectives The complexity of an electronic medication administration record (eMAR) has been underestimated by most designers in the past. Usability issues, such as poorly designed user application flow in eMAR, are therefore of vital importance, since they can have a negative impact on nursing activities and result in poor outcomes. The purpose of this study was to evaluate the usability of an eMAR application during its development. Methods A usability evaluation was conducted during the development of the eMAR application. Two usability methods were used: a heuristic evaluation complemented by usability testing. Each eMAR application version provided by the vendor was evaluated by 2 hospital pharmacists, who applied the heuristic method. They reviewed the eMAR tasks, detected usability problems and their heuristic violations, and rated the severity of the usability problems. Usability testing was used to assess the final application version by observing how 3 nurses interacted with the application. Results Thirty‐four versions were assessed before the eMAR application was considered usable. During the heuristic evaluation, the usability problems decreased from 46 unique usability problems in version 1 (V1) to 9 in version 34 (V34). In V1, usability problems were categorized into 154 heuristic violations, which decreased to 27 in V34. The average severity rating also decreased from major usability problem (2.96) to no problem (0.23). During usability testing, the 3 nurses did not encounter new usability problems. Conclusion A thorough heuristic evaluation is a good method for obtaining a usable eMAR application. This evaluation points key areas for improvement and decreases usability problems and their severity.
ISSN:1356-1294
1365-2753
DOI:10.1111/jep.12808