Biomechanics of human parietal pleura in uniaxial extension

Tension pneumothorax, a major preventable cause of battlefield death, often arises from chest trauma and is treated by needle decompression to release trapped air from the pleural cavity. Surgical simulation mannequins are often employed to train medical personnel to perform this procedure properly....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the mechanical behavior of biomedical materials 2017-11, Vol.75, p.330-335
Hauptverfasser: Tenorio, Luis E Morales, Devine, Kelsey J, Lee, Jayme, Kowalewski, Timothy M, Barocas, Victor H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 335
container_issue
container_start_page 330
container_title Journal of the mechanical behavior of biomedical materials
container_volume 75
creator Tenorio, Luis E Morales
Devine, Kelsey J
Lee, Jayme
Kowalewski, Timothy M
Barocas, Victor H
description Tension pneumothorax, a major preventable cause of battlefield death, often arises from chest trauma and is treated by needle decompression to release trapped air from the pleural cavity. Surgical simulation mannequins are often employed to train medical personnel to perform this procedure properly. Accurate reproduction of the mechanical behavior of the parietal pleura, especially in response to needle penetration, is essential to maximize the fidelity of these surgical simulators. To date, however, the design of pleura-simulating material has been largely empirical and based on subjective practitioner feel rather than on the tissue properties, which have remained unknown. In this study, we performed uniaxial extension tests on samples of cadaveric human parietal pleura. We found that the pleura was highly nonlinear and mildly anisotropic, being roughly twice as stiff in the direction parallel to the ribs vs. perpendicular to the ribs (large-strain modulus = 20.44 vs. 11.49MPa). We also did not find significant correlations for most pleural properties with age or BMI, but it must be recognized that the age range (59 ± 9.5 yrs) and BMI range (31 ± 5.3) of the donors in our study was not what one might expect from combatants, and there could be differences for younger, lighter individuals. We found a significantly higher low-strain modulus in the diabetic donors (0.213 vs. 0.100MPa), consistent with the general tendency of tissue to stiffen in diabetes. The nonlinearity and tensile strength should be considered in material design and selection for future surgical simulators.
doi_str_mv 10.1016/j.jmbbm.2017.07.044
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1926980429</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1926980429</sourcerecordid><originalsourceid>FETCH-LOGICAL-c305t-c8a12fab6041c4b74f5ee9df462fb1bf745274dbcb3afb038ac362aff3daccac3</originalsourceid><addsrcrecordid>eNo9kEtLxDAUhYMozjj6CwTp0k3rzaNpiisdfMGAG12HJE2YlL5sWhj_vRlnFA7cB-fcCx9C1xgyDJjf1Vndat1mBHCRQRRjJ2iJRSFSwAJOY1_kOOWY4wW6CKEG4ABCnKMFiSYgOV2i-0fft9ZsVedNSHqXbOdWdcmgRm8n1SRDY-dRJb5L5s6rnY8ru5tsF3zfXaIzp5pgr451hT6fnz7Wr-nm_eVt_bBJDYV8So1QmDilOTBsmC6Yy60tK8c4cRprV7CcFKzSRlPlNFChDOVEOUcrZUwcVuj2cHcY-6_Zhkm2PhjbNKqz_RwkLgkvBTBSRis9WM3YhzBaJ4fRt2r8lhjknpqs5S81uacmIYqxmLo5Pph1a6v_zB8m-gMPW2tX</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1926980429</pqid></control><display><type>article</type><title>Biomechanics of human parietal pleura in uniaxial extension</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Tenorio, Luis E Morales ; Devine, Kelsey J ; Lee, Jayme ; Kowalewski, Timothy M ; Barocas, Victor H</creator><creatorcontrib>Tenorio, Luis E Morales ; Devine, Kelsey J ; Lee, Jayme ; Kowalewski, Timothy M ; Barocas, Victor H</creatorcontrib><description>Tension pneumothorax, a major preventable cause of battlefield death, often arises from chest trauma and is treated by needle decompression to release trapped air from the pleural cavity. Surgical simulation mannequins are often employed to train medical personnel to perform this procedure properly. Accurate reproduction of the mechanical behavior of the parietal pleura, especially in response to needle penetration, is essential to maximize the fidelity of these surgical simulators. To date, however, the design of pleura-simulating material has been largely empirical and based on subjective practitioner feel rather than on the tissue properties, which have remained unknown. In this study, we performed uniaxial extension tests on samples of cadaveric human parietal pleura. We found that the pleura was highly nonlinear and mildly anisotropic, being roughly twice as stiff in the direction parallel to the ribs vs. perpendicular to the ribs (large-strain modulus = 20.44 vs. 11.49MPa). We also did not find significant correlations for most pleural properties with age or BMI, but it must be recognized that the age range (59 ± 9.5 yrs) and BMI range (31 ± 5.3) of the donors in our study was not what one might expect from combatants, and there could be differences for younger, lighter individuals. We found a significantly higher low-strain modulus in the diabetic donors (0.213 vs. 0.100MPa), consistent with the general tendency of tissue to stiffen in diabetes. The nonlinearity and tensile strength should be considered in material design and selection for future surgical simulators.</description><identifier>ISSN: 1751-6161</identifier><identifier>EISSN: 1878-0180</identifier><identifier>DOI: 10.1016/j.jmbbm.2017.07.044</identifier><identifier>PMID: 28780253</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Aged ; Anisotropy ; Biomechanical Phenomena ; Cadaver ; Humans ; Middle Aged ; Pleura - physiology ; Pneumothorax - surgery ; Ribs ; Simulation Training ; Tensile Strength</subject><ispartof>Journal of the mechanical behavior of biomedical materials, 2017-11, Vol.75, p.330-335</ispartof><rights>Copyright © 2017 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c305t-c8a12fab6041c4b74f5ee9df462fb1bf745274dbcb3afb038ac362aff3daccac3</citedby><cites>FETCH-LOGICAL-c305t-c8a12fab6041c4b74f5ee9df462fb1bf745274dbcb3afb038ac362aff3daccac3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28780253$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tenorio, Luis E Morales</creatorcontrib><creatorcontrib>Devine, Kelsey J</creatorcontrib><creatorcontrib>Lee, Jayme</creatorcontrib><creatorcontrib>Kowalewski, Timothy M</creatorcontrib><creatorcontrib>Barocas, Victor H</creatorcontrib><title>Biomechanics of human parietal pleura in uniaxial extension</title><title>Journal of the mechanical behavior of biomedical materials</title><addtitle>J Mech Behav Biomed Mater</addtitle><description>Tension pneumothorax, a major preventable cause of battlefield death, often arises from chest trauma and is treated by needle decompression to release trapped air from the pleural cavity. Surgical simulation mannequins are often employed to train medical personnel to perform this procedure properly. Accurate reproduction of the mechanical behavior of the parietal pleura, especially in response to needle penetration, is essential to maximize the fidelity of these surgical simulators. To date, however, the design of pleura-simulating material has been largely empirical and based on subjective practitioner feel rather than on the tissue properties, which have remained unknown. In this study, we performed uniaxial extension tests on samples of cadaveric human parietal pleura. We found that the pleura was highly nonlinear and mildly anisotropic, being roughly twice as stiff in the direction parallel to the ribs vs. perpendicular to the ribs (large-strain modulus = 20.44 vs. 11.49MPa). We also did not find significant correlations for most pleural properties with age or BMI, but it must be recognized that the age range (59 ± 9.5 yrs) and BMI range (31 ± 5.3) of the donors in our study was not what one might expect from combatants, and there could be differences for younger, lighter individuals. We found a significantly higher low-strain modulus in the diabetic donors (0.213 vs. 0.100MPa), consistent with the general tendency of tissue to stiffen in diabetes. The nonlinearity and tensile strength should be considered in material design and selection for future surgical simulators.</description><subject>Aged</subject><subject>Anisotropy</subject><subject>Biomechanical Phenomena</subject><subject>Cadaver</subject><subject>Humans</subject><subject>Middle Aged</subject><subject>Pleura - physiology</subject><subject>Pneumothorax - surgery</subject><subject>Ribs</subject><subject>Simulation Training</subject><subject>Tensile Strength</subject><issn>1751-6161</issn><issn>1878-0180</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kEtLxDAUhYMozjj6CwTp0k3rzaNpiisdfMGAG12HJE2YlL5sWhj_vRlnFA7cB-fcCx9C1xgyDJjf1Vndat1mBHCRQRRjJ2iJRSFSwAJOY1_kOOWY4wW6CKEG4ABCnKMFiSYgOV2i-0fft9ZsVedNSHqXbOdWdcmgRm8n1SRDY-dRJb5L5s6rnY8ru5tsF3zfXaIzp5pgr451hT6fnz7Wr-nm_eVt_bBJDYV8So1QmDilOTBsmC6Yy60tK8c4cRprV7CcFKzSRlPlNFChDOVEOUcrZUwcVuj2cHcY-6_Zhkm2PhjbNKqz_RwkLgkvBTBSRis9WM3YhzBaJ4fRt2r8lhjknpqs5S81uacmIYqxmLo5Pph1a6v_zB8m-gMPW2tX</recordid><startdate>201711</startdate><enddate>201711</enddate><creator>Tenorio, Luis E Morales</creator><creator>Devine, Kelsey J</creator><creator>Lee, Jayme</creator><creator>Kowalewski, Timothy M</creator><creator>Barocas, Victor H</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201711</creationdate><title>Biomechanics of human parietal pleura in uniaxial extension</title><author>Tenorio, Luis E Morales ; Devine, Kelsey J ; Lee, Jayme ; Kowalewski, Timothy M ; Barocas, Victor H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c305t-c8a12fab6041c4b74f5ee9df462fb1bf745274dbcb3afb038ac362aff3daccac3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Aged</topic><topic>Anisotropy</topic><topic>Biomechanical Phenomena</topic><topic>Cadaver</topic><topic>Humans</topic><topic>Middle Aged</topic><topic>Pleura - physiology</topic><topic>Pneumothorax - surgery</topic><topic>Ribs</topic><topic>Simulation Training</topic><topic>Tensile Strength</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tenorio, Luis E Morales</creatorcontrib><creatorcontrib>Devine, Kelsey J</creatorcontrib><creatorcontrib>Lee, Jayme</creatorcontrib><creatorcontrib>Kowalewski, Timothy M</creatorcontrib><creatorcontrib>Barocas, Victor H</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the mechanical behavior of biomedical materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tenorio, Luis E Morales</au><au>Devine, Kelsey J</au><au>Lee, Jayme</au><au>Kowalewski, Timothy M</au><au>Barocas, Victor H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biomechanics of human parietal pleura in uniaxial extension</atitle><jtitle>Journal of the mechanical behavior of biomedical materials</jtitle><addtitle>J Mech Behav Biomed Mater</addtitle><date>2017-11</date><risdate>2017</risdate><volume>75</volume><spage>330</spage><epage>335</epage><pages>330-335</pages><issn>1751-6161</issn><eissn>1878-0180</eissn><abstract>Tension pneumothorax, a major preventable cause of battlefield death, often arises from chest trauma and is treated by needle decompression to release trapped air from the pleural cavity. Surgical simulation mannequins are often employed to train medical personnel to perform this procedure properly. Accurate reproduction of the mechanical behavior of the parietal pleura, especially in response to needle penetration, is essential to maximize the fidelity of these surgical simulators. To date, however, the design of pleura-simulating material has been largely empirical and based on subjective practitioner feel rather than on the tissue properties, which have remained unknown. In this study, we performed uniaxial extension tests on samples of cadaveric human parietal pleura. We found that the pleura was highly nonlinear and mildly anisotropic, being roughly twice as stiff in the direction parallel to the ribs vs. perpendicular to the ribs (large-strain modulus = 20.44 vs. 11.49MPa). We also did not find significant correlations for most pleural properties with age or BMI, but it must be recognized that the age range (59 ± 9.5 yrs) and BMI range (31 ± 5.3) of the donors in our study was not what one might expect from combatants, and there could be differences for younger, lighter individuals. We found a significantly higher low-strain modulus in the diabetic donors (0.213 vs. 0.100MPa), consistent with the general tendency of tissue to stiffen in diabetes. The nonlinearity and tensile strength should be considered in material design and selection for future surgical simulators.</abstract><cop>Netherlands</cop><pmid>28780253</pmid><doi>10.1016/j.jmbbm.2017.07.044</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1751-6161
ispartof Journal of the mechanical behavior of biomedical materials, 2017-11, Vol.75, p.330-335
issn 1751-6161
1878-0180
language eng
recordid cdi_proquest_miscellaneous_1926980429
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Aged
Anisotropy
Biomechanical Phenomena
Cadaver
Humans
Middle Aged
Pleura - physiology
Pneumothorax - surgery
Ribs
Simulation Training
Tensile Strength
title Biomechanics of human parietal pleura in uniaxial extension
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T18%3A21%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biomechanics%20of%20human%20parietal%20pleura%20in%20uniaxial%20extension&rft.jtitle=Journal%20of%20the%20mechanical%20behavior%20of%20biomedical%20materials&rft.au=Tenorio,%20Luis%20E%20Morales&rft.date=2017-11&rft.volume=75&rft.spage=330&rft.epage=335&rft.pages=330-335&rft.issn=1751-6161&rft.eissn=1878-0180&rft_id=info:doi/10.1016/j.jmbbm.2017.07.044&rft_dat=%3Cproquest_cross%3E1926980429%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1926980429&rft_id=info:pmid/28780253&rfr_iscdi=true