Ultrasound-guided fine-needle capillary cytology of parotid gland masses coupled with a rapid-on-site evaluation improves results

To test whether a direct-on-site microscopic examination of fresh, unstained puncture slides by the radiologist decreases the rate of false-negative cases on ultrasound-guided fine-needle cytology of parotid gland masses. Thirty parotid gland masses from 28 patients were punctured under ultrasound g...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Morphologie 2018-03, Vol.102 (336), p.25-30
Hauptverfasser: Barats, R., Evrard, S., Collin, L., Vergez, S., Gellée, S., Courtade-Saïdi, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 30
container_issue 336
container_start_page 25
container_title Morphologie
container_volume 102
creator Barats, R.
Evrard, S.
Collin, L.
Vergez, S.
Gellée, S.
Courtade-Saïdi, M.
description To test whether a direct-on-site microscopic examination of fresh, unstained puncture slides by the radiologist decreases the rate of false-negative cases on ultrasound-guided fine-needle cytology of parotid gland masses. Thirty parotid gland masses from 28 patients were punctured under ultrasound guidance. The same group was used as its control group. After one or two passes, the material was spread on slides and air-dried (control group, without microscopic examination). For the study group, it was thus analyzed unstained under the microscope. A sample was considered adequate if at least six clusters of parotid cells were found per slide on at least two slides. For the study group, new punctures were obtained and slides prepared until this condition was fulfilled. Of the 30 evaluated masses, 100% benefited from a cytological diagnosis after microscopy. Twenty-four were adequate in the control group, while 30 were adequate in the study group. The maximum number of punctures to obtain an adequate sample was six. On-site direct microscopy significantly increased the number of adequate specimens by 20% (P=0.03, CI [1.63–20%]). Direct and systematic examination of slides by a radiologist avoided the risk of false-negative results caused by having insufficient sample material. Évaluer si l’examen microscopique direct à l’état frais par le radiologue de lames de cytoponctions écho-guidées parotidiennes diminue le taux de faux-négatifs. Trente tumeurs parotidiennes provenant de 28 patients ont fait l’objet d’une cytoponction écho-guidée. Le même groupe de patients a servi de témoin. Après un ou deux passages à l’aiguille, le matériel était étalé sur lames et séché à l’air (groupe témoin, sans examen microscopique direct). Pour le groupe expérimental, le matériel était examiné au microscope sans coloration. Un échantillon était considéré comme adéquat si au moins 6 amas cellulaires étaient présents par lame sur au moins deux lames. Dans le groupe expérimental, de nouvelles ponctions étaient réalisées si ce critère n’était pas rempli jusqu’à son obtention. Sur les 30 tumeurs prélevées, 100 % ont bénéficié de l’examen microscopique direct. Vingt-quatre ponctions étaient satisfaisantes dans le groupe témoin et 30 dans le groupe expérimental. Le nombre maximal de ponctions pour obtenir du matériel satisfaisant était de six. L’examen direct sur place a augmenté de 20 % le nombre d’échantillons satisfaisants pour évaluation (p=0,03, IC [1,63–20 %]). L’examen microscopi
doi_str_mv 10.1016/j.morpho.2017.06.003
format Article
fullrecord <record><control><sourceid>proquest_hal_p</sourceid><recordid>TN_cdi_proquest_miscellaneous_1922508861</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S128601151730053X</els_id><sourcerecordid>1922508861</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-3bc82f1a096fb0172419d99e7817bb33ecaf867473688f344f61f7ba7e289d93</originalsourceid><addsrcrecordid>eNp9kcGOFCEQhjlo3HX1DYzhqIduoekF-mKy2ahrMomX9UxoKGaY0E0L9Jg5-uYy6XWPnkgq319F1YfQO0paSij_dGynmJZDbDtCRUt4Swh7ga5pJ3lDKL29Qq9zPhLSU9aLV-iqk4J1XMhr9OdnKEnnuM622a_egsXOz9DMADYANnrxIeh0xuZcYoj7M44OLzrF4i3eBz1bPOmcIWMT1yXU-G9fDljjVJO2iXOTfQEMJx1WXXycsZ-WFE81kCCvoeQ36KXTIcPbp_cGPX798nj_0Ox-fPt-f7drDKO0NGw0snNUk4G7sW7Z9XSwwwBCUjGOjIHRTnLRC8aldKzvHadOjFpAJyvIbtDHre1BB7UkP9WlVNRePdzt1KVG-oGJQcoTreyHja0__bVCLmry2UA9xAxxzYoOXXdLpOQXtN9Qk2LOCdxzb0rUxY06qs2NurhRhKvqpsbeP01Yxwnsc-ifmAp83gCoJzl5SCobD7MB6xOYomz0_5_wF23Rpgg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1922508861</pqid></control><display><type>article</type><title>Ultrasound-guided fine-needle capillary cytology of parotid gland masses coupled with a rapid-on-site evaluation improves results</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Barats, R. ; Evrard, S. ; Collin, L. ; Vergez, S. ; Gellée, S. ; Courtade-Saïdi, M.</creator><creatorcontrib>Barats, R. ; Evrard, S. ; Collin, L. ; Vergez, S. ; Gellée, S. ; Courtade-Saïdi, M.</creatorcontrib><description>To test whether a direct-on-site microscopic examination of fresh, unstained puncture slides by the radiologist decreases the rate of false-negative cases on ultrasound-guided fine-needle cytology of parotid gland masses. Thirty parotid gland masses from 28 patients were punctured under ultrasound guidance. The same group was used as its control group. After one or two passes, the material was spread on slides and air-dried (control group, without microscopic examination). For the study group, it was thus analyzed unstained under the microscope. A sample was considered adequate if at least six clusters of parotid cells were found per slide on at least two slides. For the study group, new punctures were obtained and slides prepared until this condition was fulfilled. Of the 30 evaluated masses, 100% benefited from a cytological diagnosis after microscopy. Twenty-four were adequate in the control group, while 30 were adequate in the study group. The maximum number of punctures to obtain an adequate sample was six. On-site direct microscopy significantly increased the number of adequate specimens by 20% (P=0.03, CI [1.63–20%]). Direct and systematic examination of slides by a radiologist avoided the risk of false-negative results caused by having insufficient sample material. Évaluer si l’examen microscopique direct à l’état frais par le radiologue de lames de cytoponctions écho-guidées parotidiennes diminue le taux de faux-négatifs. Trente tumeurs parotidiennes provenant de 28 patients ont fait l’objet d’une cytoponction écho-guidée. Le même groupe de patients a servi de témoin. Après un ou deux passages à l’aiguille, le matériel était étalé sur lames et séché à l’air (groupe témoin, sans examen microscopique direct). Pour le groupe expérimental, le matériel était examiné au microscope sans coloration. Un échantillon était considéré comme adéquat si au moins 6 amas cellulaires étaient présents par lame sur au moins deux lames. Dans le groupe expérimental, de nouvelles ponctions étaient réalisées si ce critère n’était pas rempli jusqu’à son obtention. Sur les 30 tumeurs prélevées, 100 % ont bénéficié de l’examen microscopique direct. Vingt-quatre ponctions étaient satisfaisantes dans le groupe témoin et 30 dans le groupe expérimental. Le nombre maximal de ponctions pour obtenir du matériel satisfaisant était de six. L’examen direct sur place a augmenté de 20 % le nombre d’échantillons satisfaisants pour évaluation (p=0,03, IC [1,63–20 %]). L’examen microscopique direct systématique des lames de cytoponction par le radiologue évite le risque de faux-négatifs liés à un matériel insuffisant.</description><identifier>ISSN: 1286-0115</identifier><identifier>DOI: 10.1016/j.morpho.2017.06.003</identifier><identifier>PMID: 28732678</identifier><language>eng</language><publisher>France: Elsevier Masson SAS</publisher><subject>Direct-on-site evaluation ; Life Sciences ; Parotid gland ; Ultrasound-guided fine-needle cytology</subject><ispartof>Morphologie, 2018-03, Vol.102 (336), p.25-30</ispartof><rights>2017 Elsevier Masson SAS</rights><rights>Copyright © 2017 Elsevier Masson SAS. All rights reserved.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-3bc82f1a096fb0172419d99e7817bb33ecaf867473688f344f61f7ba7e289d93</citedby><cites>FETCH-LOGICAL-c311t-3bc82f1a096fb0172419d99e7817bb33ecaf867473688f344f61f7ba7e289d93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S128601151730053X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>230,314,776,780,881,3537,27901,27902,65534</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28732678$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-04937988$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Barats, R.</creatorcontrib><creatorcontrib>Evrard, S.</creatorcontrib><creatorcontrib>Collin, L.</creatorcontrib><creatorcontrib>Vergez, S.</creatorcontrib><creatorcontrib>Gellée, S.</creatorcontrib><creatorcontrib>Courtade-Saïdi, M.</creatorcontrib><title>Ultrasound-guided fine-needle capillary cytology of parotid gland masses coupled with a rapid-on-site evaluation improves results</title><title>Morphologie</title><addtitle>Morphologie</addtitle><description>To test whether a direct-on-site microscopic examination of fresh, unstained puncture slides by the radiologist decreases the rate of false-negative cases on ultrasound-guided fine-needle cytology of parotid gland masses. Thirty parotid gland masses from 28 patients were punctured under ultrasound guidance. The same group was used as its control group. After one or two passes, the material was spread on slides and air-dried (control group, without microscopic examination). For the study group, it was thus analyzed unstained under the microscope. A sample was considered adequate if at least six clusters of parotid cells were found per slide on at least two slides. For the study group, new punctures were obtained and slides prepared until this condition was fulfilled. Of the 30 evaluated masses, 100% benefited from a cytological diagnosis after microscopy. Twenty-four were adequate in the control group, while 30 were adequate in the study group. The maximum number of punctures to obtain an adequate sample was six. On-site direct microscopy significantly increased the number of adequate specimens by 20% (P=0.03, CI [1.63–20%]). Direct and systematic examination of slides by a radiologist avoided the risk of false-negative results caused by having insufficient sample material. Évaluer si l’examen microscopique direct à l’état frais par le radiologue de lames de cytoponctions écho-guidées parotidiennes diminue le taux de faux-négatifs. Trente tumeurs parotidiennes provenant de 28 patients ont fait l’objet d’une cytoponction écho-guidée. Le même groupe de patients a servi de témoin. Après un ou deux passages à l’aiguille, le matériel était étalé sur lames et séché à l’air (groupe témoin, sans examen microscopique direct). Pour le groupe expérimental, le matériel était examiné au microscope sans coloration. Un échantillon était considéré comme adéquat si au moins 6 amas cellulaires étaient présents par lame sur au moins deux lames. Dans le groupe expérimental, de nouvelles ponctions étaient réalisées si ce critère n’était pas rempli jusqu’à son obtention. Sur les 30 tumeurs prélevées, 100 % ont bénéficié de l’examen microscopique direct. Vingt-quatre ponctions étaient satisfaisantes dans le groupe témoin et 30 dans le groupe expérimental. Le nombre maximal de ponctions pour obtenir du matériel satisfaisant était de six. L’examen direct sur place a augmenté de 20 % le nombre d’échantillons satisfaisants pour évaluation (p=0,03, IC [1,63–20 %]). L’examen microscopique direct systématique des lames de cytoponction par le radiologue évite le risque de faux-négatifs liés à un matériel insuffisant.</description><subject>Direct-on-site evaluation</subject><subject>Life Sciences</subject><subject>Parotid gland</subject><subject>Ultrasound-guided fine-needle cytology</subject><issn>1286-0115</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kcGOFCEQhjlo3HX1DYzhqIduoekF-mKy2ahrMomX9UxoKGaY0E0L9Jg5-uYy6XWPnkgq319F1YfQO0paSij_dGynmJZDbDtCRUt4Swh7ga5pJ3lDKL29Qq9zPhLSU9aLV-iqk4J1XMhr9OdnKEnnuM622a_egsXOz9DMADYANnrxIeh0xuZcYoj7M44OLzrF4i3eBz1bPOmcIWMT1yXU-G9fDljjVJO2iXOTfQEMJx1WXXycsZ-WFE81kCCvoeQ36KXTIcPbp_cGPX798nj_0Ox-fPt-f7drDKO0NGw0snNUk4G7sW7Z9XSwwwBCUjGOjIHRTnLRC8aldKzvHadOjFpAJyvIbtDHre1BB7UkP9WlVNRePdzt1KVG-oGJQcoTreyHja0__bVCLmry2UA9xAxxzYoOXXdLpOQXtN9Qk2LOCdxzb0rUxY06qs2NurhRhKvqpsbeP01Yxwnsc-ifmAp83gCoJzl5SCobD7MB6xOYomz0_5_wF23Rpgg</recordid><startdate>201803</startdate><enddate>201803</enddate><creator>Barats, R.</creator><creator>Evrard, S.</creator><creator>Collin, L.</creator><creator>Vergez, S.</creator><creator>Gellée, S.</creator><creator>Courtade-Saïdi, M.</creator><general>Elsevier Masson SAS</general><general>Elsevier Masson</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope></search><sort><creationdate>201803</creationdate><title>Ultrasound-guided fine-needle capillary cytology of parotid gland masses coupled with a rapid-on-site evaluation improves results</title><author>Barats, R. ; Evrard, S. ; Collin, L. ; Vergez, S. ; Gellée, S. ; Courtade-Saïdi, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-3bc82f1a096fb0172419d99e7817bb33ecaf867473688f344f61f7ba7e289d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Direct-on-site evaluation</topic><topic>Life Sciences</topic><topic>Parotid gland</topic><topic>Ultrasound-guided fine-needle cytology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Barats, R.</creatorcontrib><creatorcontrib>Evrard, S.</creatorcontrib><creatorcontrib>Collin, L.</creatorcontrib><creatorcontrib>Vergez, S.</creatorcontrib><creatorcontrib>Gellée, S.</creatorcontrib><creatorcontrib>Courtade-Saïdi, M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><jtitle>Morphologie</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Barats, R.</au><au>Evrard, S.</au><au>Collin, L.</au><au>Vergez, S.</au><au>Gellée, S.</au><au>Courtade-Saïdi, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ultrasound-guided fine-needle capillary cytology of parotid gland masses coupled with a rapid-on-site evaluation improves results</atitle><jtitle>Morphologie</jtitle><addtitle>Morphologie</addtitle><date>2018-03</date><risdate>2018</risdate><volume>102</volume><issue>336</issue><spage>25</spage><epage>30</epage><pages>25-30</pages><issn>1286-0115</issn><abstract>To test whether a direct-on-site microscopic examination of fresh, unstained puncture slides by the radiologist decreases the rate of false-negative cases on ultrasound-guided fine-needle cytology of parotid gland masses. Thirty parotid gland masses from 28 patients were punctured under ultrasound guidance. The same group was used as its control group. After one or two passes, the material was spread on slides and air-dried (control group, without microscopic examination). For the study group, it was thus analyzed unstained under the microscope. A sample was considered adequate if at least six clusters of parotid cells were found per slide on at least two slides. For the study group, new punctures were obtained and slides prepared until this condition was fulfilled. Of the 30 evaluated masses, 100% benefited from a cytological diagnosis after microscopy. Twenty-four were adequate in the control group, while 30 were adequate in the study group. The maximum number of punctures to obtain an adequate sample was six. On-site direct microscopy significantly increased the number of adequate specimens by 20% (P=0.03, CI [1.63–20%]). Direct and systematic examination of slides by a radiologist avoided the risk of false-negative results caused by having insufficient sample material. Évaluer si l’examen microscopique direct à l’état frais par le radiologue de lames de cytoponctions écho-guidées parotidiennes diminue le taux de faux-négatifs. Trente tumeurs parotidiennes provenant de 28 patients ont fait l’objet d’une cytoponction écho-guidée. Le même groupe de patients a servi de témoin. Après un ou deux passages à l’aiguille, le matériel était étalé sur lames et séché à l’air (groupe témoin, sans examen microscopique direct). Pour le groupe expérimental, le matériel était examiné au microscope sans coloration. Un échantillon était considéré comme adéquat si au moins 6 amas cellulaires étaient présents par lame sur au moins deux lames. Dans le groupe expérimental, de nouvelles ponctions étaient réalisées si ce critère n’était pas rempli jusqu’à son obtention. Sur les 30 tumeurs prélevées, 100 % ont bénéficié de l’examen microscopique direct. Vingt-quatre ponctions étaient satisfaisantes dans le groupe témoin et 30 dans le groupe expérimental. Le nombre maximal de ponctions pour obtenir du matériel satisfaisant était de six. L’examen direct sur place a augmenté de 20 % le nombre d’échantillons satisfaisants pour évaluation (p=0,03, IC [1,63–20 %]). L’examen microscopique direct systématique des lames de cytoponction par le radiologue évite le risque de faux-négatifs liés à un matériel insuffisant.</abstract><cop>France</cop><pub>Elsevier Masson SAS</pub><pmid>28732678</pmid><doi>10.1016/j.morpho.2017.06.003</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1286-0115
ispartof Morphologie, 2018-03, Vol.102 (336), p.25-30
issn 1286-0115
language eng
recordid cdi_proquest_miscellaneous_1922508861
source Elsevier ScienceDirect Journals Complete
subjects Direct-on-site evaluation
Life Sciences
Parotid gland
Ultrasound-guided fine-needle cytology
title Ultrasound-guided fine-needle capillary cytology of parotid gland masses coupled with a rapid-on-site evaluation improves results
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-15T18%3A41%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_hal_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ultrasound-guided%20fine-needle%20capillary%20cytology%20of%20parotid%20gland%20masses%20coupled%20with%20a%20rapid-on-site%20evaluation%20improves%20results&rft.jtitle=Morphologie&rft.au=Barats,%20R.&rft.date=2018-03&rft.volume=102&rft.issue=336&rft.spage=25&rft.epage=30&rft.pages=25-30&rft.issn=1286-0115&rft_id=info:doi/10.1016/j.morpho.2017.06.003&rft_dat=%3Cproquest_hal_p%3E1922508861%3C/proquest_hal_p%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1922508861&rft_id=info:pmid/28732678&rft_els_id=S128601151730053X&rfr_iscdi=true