Application of a pH Electrode Incorporating an Ionic Liquid Salt Bridge to the Measurement of Rainwater Samples

A pH electrode incorporating a reference electrode different from that in conventional electrodes was applied to the measurement of rainwater pH. The reference electrode utilizes a recently proposed ionic liquid salt bridge instead of a conventional potassium chloride salt bridge. The response time...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical Sciences 2017/06/10, Vol.33(6), pp.739-742
Hauptverfasser: KUDO, Yota, SHIBATA, Manabu, NOMURA, Satoshi, OGAWA, Nobuaki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 742
container_issue 6
container_start_page 739
container_title Analytical Sciences
container_volume 33
creator KUDO, Yota
SHIBATA, Manabu
NOMURA, Satoshi
OGAWA, Nobuaki
description A pH electrode incorporating a reference electrode different from that in conventional electrodes was applied to the measurement of rainwater pH. The reference electrode utilizes a recently proposed ionic liquid salt bridge instead of a conventional potassium chloride salt bridge. The response time of this electrode was remarkably improved in rain sample pH measurements compared to that of conventional pH electrodes. In addition, the measured pH values of rain samples seemed to be more accurate with this electrode.
doi_str_mv 10.2116/analsci.33.739
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1908799201</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1916094157</sourcerecordid><originalsourceid>FETCH-LOGICAL-c655t-bc2417e2eb41e14a5c94a1204bde0e06e6b55f7929037fa839815717346c2e973</originalsourceid><addsrcrecordid>eNp1kUuP0zAURi0EYsrAliWyxIZNOn7FjpdlNDCVipB4rCPHuem4SuyM7Qjx73HVUo2QWHnxne9c616E3lKyZpTKG-PNmKxbc75WXD9DK8pFUzEm5HO0IpqSSnJBrtCrlA6EUNYw9hJdsUYSTrVaobCZ59FZk13wOAzY4Pke341gcww94K23Ic4hltzvsfF4G7yzeOceF9fj72bM-GN0_R5wDjg_AP4CJi0RJvD5qPtmnP9lMsTCTvMI6TV6MZQfw5vze41-frr7cXtf7b5-3t5udpWVdZ2rzjJBFTDoBAUqTG21MJQR0fVAgEiQXV0PSjNNuBpMw3VDa0UVF9Iy0Ipfow8n7xzD4wIpt5NLFsbReAhLaqkmjdKaEVrQ9_-gh7DE414LRSXRoqgLtT5RNoaUIgztHN1k4u-WkvZ4ivZ8ipbztpyiFN6dtUs3QX_B_-6-ADcnIJXI7yE-mfs_5ebUOKRs9nBRmpidHeEpLs-dS2YfTGzB8z_yqKz0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1916094157</pqid></control><display><type>article</type><title>Application of a pH Electrode Incorporating an Ionic Liquid Salt Bridge to the Measurement of Rainwater Samples</title><source>J-STAGE Free</source><source>Open Access Titles of Japan</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Free Full-Text Journals in Chemistry</source><source>SpringerLink Journals - AutoHoldings</source><creator>KUDO, Yota ; SHIBATA, Manabu ; NOMURA, Satoshi ; OGAWA, Nobuaki</creator><creatorcontrib>KUDO, Yota ; SHIBATA, Manabu ; NOMURA, Satoshi ; OGAWA, Nobuaki</creatorcontrib><description>A pH electrode incorporating a reference electrode different from that in conventional electrodes was applied to the measurement of rainwater pH. The reference electrode utilizes a recently proposed ionic liquid salt bridge instead of a conventional potassium chloride salt bridge. The response time of this electrode was remarkably improved in rain sample pH measurements compared to that of conventional pH electrodes. In addition, the measured pH values of rain samples seemed to be more accurate with this electrode.</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.2116/analsci.33.739</identifier><identifier>PMID: 28603197</identifier><language>eng</language><publisher>Singapore: The Japan Society for Analytical Chemistry</publisher><subject>Analytical Chemistry ; Chemistry ; dilute solution ; Electrodes ; Hydrogen ions ; ionic liquid ; Ionic liquids ; Ions ; pH effects ; pH electrode ; Potassium ; Potassium chloride ; Rain ; rain sample ; Rain water ; reference electrode ; Response time ; salt bridge ; Salts</subject><ispartof>Analytical Sciences, 2017/06/10, Vol.33(6), pp.739-742</ispartof><rights>2017 by The Japan Society for Analytical Chemistry</rights><rights>The Japan Society for Analytical Chemistry 2017</rights><rights>Copyright Japan Science and Technology Agency 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c655t-bc2417e2eb41e14a5c94a1204bde0e06e6b55f7929037fa839815717346c2e973</citedby><cites>FETCH-LOGICAL-c655t-bc2417e2eb41e14a5c94a1204bde0e06e6b55f7929037fa839815717346c2e973</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.2116/analsci.33.739$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.2116/analsci.33.739$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,1883,27924,27925,41488,42557,51319</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28603197$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KUDO, Yota</creatorcontrib><creatorcontrib>SHIBATA, Manabu</creatorcontrib><creatorcontrib>NOMURA, Satoshi</creatorcontrib><creatorcontrib>OGAWA, Nobuaki</creatorcontrib><title>Application of a pH Electrode Incorporating an Ionic Liquid Salt Bridge to the Measurement of Rainwater Samples</title><title>Analytical Sciences</title><addtitle>ANAL. SCI</addtitle><addtitle>Anal Sci</addtitle><description>A pH electrode incorporating a reference electrode different from that in conventional electrodes was applied to the measurement of rainwater pH. The reference electrode utilizes a recently proposed ionic liquid salt bridge instead of a conventional potassium chloride salt bridge. The response time of this electrode was remarkably improved in rain sample pH measurements compared to that of conventional pH electrodes. In addition, the measured pH values of rain samples seemed to be more accurate with this electrode.</description><subject>Analytical Chemistry</subject><subject>Chemistry</subject><subject>dilute solution</subject><subject>Electrodes</subject><subject>Hydrogen ions</subject><subject>ionic liquid</subject><subject>Ionic liquids</subject><subject>Ions</subject><subject>pH effects</subject><subject>pH electrode</subject><subject>Potassium</subject><subject>Potassium chloride</subject><subject>Rain</subject><subject>rain sample</subject><subject>Rain water</subject><subject>reference electrode</subject><subject>Response time</subject><subject>salt bridge</subject><subject>Salts</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp1kUuP0zAURi0EYsrAliWyxIZNOn7FjpdlNDCVipB4rCPHuem4SuyM7Qjx73HVUo2QWHnxne9c616E3lKyZpTKG-PNmKxbc75WXD9DK8pFUzEm5HO0IpqSSnJBrtCrlA6EUNYw9hJdsUYSTrVaobCZ59FZk13wOAzY4Pke341gcww94K23Ic4hltzvsfF4G7yzeOceF9fj72bM-GN0_R5wDjg_AP4CJi0RJvD5qPtmnP9lMsTCTvMI6TV6MZQfw5vze41-frr7cXtf7b5-3t5udpWVdZ2rzjJBFTDoBAUqTG21MJQR0fVAgEiQXV0PSjNNuBpMw3VDa0UVF9Iy0Ipfow8n7xzD4wIpt5NLFsbReAhLaqkmjdKaEVrQ9_-gh7DE414LRSXRoqgLtT5RNoaUIgztHN1k4u-WkvZ4ivZ8ipbztpyiFN6dtUs3QX_B_-6-ADcnIJXI7yE-mfs_5ebUOKRs9nBRmpidHeEpLs-dS2YfTGzB8z_yqKz0</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>KUDO, Yota</creator><creator>SHIBATA, Manabu</creator><creator>NOMURA, Satoshi</creator><creator>OGAWA, Nobuaki</creator><general>The Japan Society for Analytical Chemistry</general><general>Springer Nature Singapore</general><general>Japan Science and Technology Agency</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>H8G</scope><scope>JG9</scope><scope>L7M</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>2017</creationdate><title>Application of a pH Electrode Incorporating an Ionic Liquid Salt Bridge to the Measurement of Rainwater Samples</title><author>KUDO, Yota ; SHIBATA, Manabu ; NOMURA, Satoshi ; OGAWA, Nobuaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c655t-bc2417e2eb41e14a5c94a1204bde0e06e6b55f7929037fa839815717346c2e973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Analytical Chemistry</topic><topic>Chemistry</topic><topic>dilute solution</topic><topic>Electrodes</topic><topic>Hydrogen ions</topic><topic>ionic liquid</topic><topic>Ionic liquids</topic><topic>Ions</topic><topic>pH effects</topic><topic>pH electrode</topic><topic>Potassium</topic><topic>Potassium chloride</topic><topic>Rain</topic><topic>rain sample</topic><topic>Rain water</topic><topic>reference electrode</topic><topic>Response time</topic><topic>salt bridge</topic><topic>Salts</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KUDO, Yota</creatorcontrib><creatorcontrib>SHIBATA, Manabu</creatorcontrib><creatorcontrib>NOMURA, Satoshi</creatorcontrib><creatorcontrib>OGAWA, Nobuaki</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical Sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KUDO, Yota</au><au>SHIBATA, Manabu</au><au>NOMURA, Satoshi</au><au>OGAWA, Nobuaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of a pH Electrode Incorporating an Ionic Liquid Salt Bridge to the Measurement of Rainwater Samples</atitle><jtitle>Analytical Sciences</jtitle><stitle>ANAL. SCI</stitle><addtitle>Anal Sci</addtitle><date>2017</date><risdate>2017</risdate><volume>33</volume><issue>6</issue><spage>739</spage><epage>742</epage><pages>739-742</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><abstract>A pH electrode incorporating a reference electrode different from that in conventional electrodes was applied to the measurement of rainwater pH. The reference electrode utilizes a recently proposed ionic liquid salt bridge instead of a conventional potassium chloride salt bridge. The response time of this electrode was remarkably improved in rain sample pH measurements compared to that of conventional pH electrodes. In addition, the measured pH values of rain samples seemed to be more accurate with this electrode.</abstract><cop>Singapore</cop><pub>The Japan Society for Analytical Chemistry</pub><pmid>28603197</pmid><doi>10.2116/analsci.33.739</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0910-6340
ispartof Analytical Sciences, 2017/06/10, Vol.33(6), pp.739-742
issn 0910-6340
1348-2246
language eng
recordid cdi_proquest_miscellaneous_1908799201
source J-STAGE Free; Open Access Titles of Japan; EZB-FREE-00999 freely available EZB journals; Free Full-Text Journals in Chemistry; SpringerLink Journals - AutoHoldings
subjects Analytical Chemistry
Chemistry
dilute solution
Electrodes
Hydrogen ions
ionic liquid
Ionic liquids
Ions
pH effects
pH electrode
Potassium
Potassium chloride
Rain
rain sample
Rain water
reference electrode
Response time
salt bridge
Salts
title Application of a pH Electrode Incorporating an Ionic Liquid Salt Bridge to the Measurement of Rainwater Samples
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T11%3A21%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20a%20pH%20Electrode%20Incorporating%20an%20Ionic%20Liquid%20Salt%20Bridge%20to%20the%20Measurement%20of%20Rainwater%20Samples&rft.jtitle=Analytical%20Sciences&rft.au=KUDO,%20Yota&rft.date=2017&rft.volume=33&rft.issue=6&rft.spage=739&rft.epage=742&rft.pages=739-742&rft.issn=0910-6340&rft.eissn=1348-2246&rft_id=info:doi/10.2116/analsci.33.739&rft_dat=%3Cproquest_cross%3E1916094157%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1916094157&rft_id=info:pmid/28603197&rfr_iscdi=true