Evaluation of conventional and frozen elephant trunk techniques on spinal cord blood flow in an animal model
Abstract OBJECTIVES The treatment of patients with extensive thoracic aortic disease involving the arch and descending aorta is often performed using the frozen elephant trunk technique (FET). Spinal cord blood flow (SCBF) in cervical, thoracic and lumbar sections prior, during and after aortic arch...
Gespeichert in:
Veröffentlicht in: | European journal of cardio-thoracic surgery 2017-09, Vol.52 (3), p.485-491 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 491 |
---|---|
container_issue | 3 |
container_start_page | 485 |
container_title | European journal of cardio-thoracic surgery |
container_volume | 52 |
creator | Leontyev, Sergey Dieterlen, Maja-Theresa Halling, Michelle Schlegel, Franziska Hoyer, Alexandro Ossmann, Susann Klaeske, Kerstin Etz, Christian D. Mohr, Friedrich W. |
description | Abstract
OBJECTIVES
The treatment of patients with extensive thoracic aortic disease involving the arch and descending aorta is often performed using the frozen elephant trunk technique (FET). Spinal cord blood flow (SCBF) in cervical, thoracic and lumbar sections prior, during and after aortic arch surgery were compared in conventional elephant trunk (cET) and FET technique in a pig model.
METHODS
German Landrace pigs (75–85 kg) underwent aortic arch surgery using the FET (n = 8) or cET (n = 8) techniques. The E-vita Open hybrid stent graft was applied in all FET animals. Regional SCBF was measured 4 times: (i) before cardiopulmonary bypass, (ii) after 1 h, (iii) after 3 h, and (iv) after 6 h of reperfusion using fluorescence microspheres. Spinal cord segments were examined histopathologically and by immunohistochemistry.
RESULTS
SCBF in FET decreased significantly from 0.13 ± 0.03 to 0.05 ± 0.02 ml/min/g after 1 h (P = 0.047). While at 3 h of reperfusion, SCBF increased and was comparable to baseline (0.09 ± 0.01 ml/min/g), beyond this time SCBF decreased again (0.05 ± 0.02 ml/min/g). A similar trend was found for SCBF in the cET group (baseline: 0.16 ± 0.04 ml/min/g, 1 h reperfusion: 0.02 ± 0.01 ml/min/g, 3 h reperfusion: 0.03 ± 0.01 ml/min/g and 6 h reperfusion: 0.02 ± 0.01 ml/min/g, P = 0.019). Cervical, thoracic and lumbar SCBF were also comparable in both groups. Histological analyses of spinal cord showed no differences in necrosis between cET and FET, while no differences were found for hypoxia-inducible factor-1α and apoptosis-inducing factor. In contrast, oxidative stress and caspase-induced apoptosis were higher in cET versus FET.
CONCLUSIONS
The SCBF changed significantly during extensive aortic arch surgery with circulatory arrest and moderate hypothermia, but such changes were comparable between the FET and cET groups. The implantation of hybrid stent graft did not influence SCBF in thoracic and lumbar segments of the spinal cord. The immunohistological examination showed no differences between cET and FET regarding ischaemic damage and hypoxia-induced effects in spinal cord segments. |
doi_str_mv | 10.1093/ejcts/ezx085 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1900834236</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/ejcts/ezx085</oup_id><sourcerecordid>1900834236</sourcerecordid><originalsourceid>FETCH-LOGICAL-c361t-d656a8f60186db6c6126af199735ec7a40af77cba221505f3e0e631456ff7a73</originalsourceid><addsrcrecordid>eNp9kL1PwzAQxS0EoqWwMSNvMBBqx7GdjKgqH1Illg5skeuc1RTXDnFSoH89Li2MSCfdne53T08PoUtK7igp2BhWugtj2H6SnB-hIc0lSyTLXo_jTChJZJGRAToLYUUIESyVp2iQ5jzlnLMhstONsr3qau-wN1h7twG325TFylXYtH4LDoOFZqlch7u2d2-4A7109XsPAce_0NQ7XPu2wgvrffyy_gPXLirEqtfxuPYV2HN0YpQNcHHoIzR_mM4nT8ns5fF5cj9LNBO0SyrBhcqNIDQX1UJoQVOhDC0KyThoqTKijJR6odKUcsINAwKC0YwLY6SSbIRu9rJN63ceu3JdBw3WKge-DyUtCMlZljIR0ds9qlsfQgumbNrot_0qKSl38ZY_8Zb7eCN-dVDuF2uo_uDfPCNwvQd83_wv9Q28UIar</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1900834236</pqid></control><display><type>article</type><title>Evaluation of conventional and frozen elephant trunk techniques on spinal cord blood flow in an animal model</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Oxford University Press Journals All Titles (1996-Current)</source><source>Alma/SFX Local Collection</source><creator>Leontyev, Sergey ; Dieterlen, Maja-Theresa ; Halling, Michelle ; Schlegel, Franziska ; Hoyer, Alexandro ; Ossmann, Susann ; Klaeske, Kerstin ; Etz, Christian D. ; Mohr, Friedrich W.</creator><creatorcontrib>Leontyev, Sergey ; Dieterlen, Maja-Theresa ; Halling, Michelle ; Schlegel, Franziska ; Hoyer, Alexandro ; Ossmann, Susann ; Klaeske, Kerstin ; Etz, Christian D. ; Mohr, Friedrich W.</creatorcontrib><description>Abstract
OBJECTIVES
The treatment of patients with extensive thoracic aortic disease involving the arch and descending aorta is often performed using the frozen elephant trunk technique (FET). Spinal cord blood flow (SCBF) in cervical, thoracic and lumbar sections prior, during and after aortic arch surgery were compared in conventional elephant trunk (cET) and FET technique in a pig model.
METHODS
German Landrace pigs (75–85 kg) underwent aortic arch surgery using the FET (n = 8) or cET (n = 8) techniques. The E-vita Open hybrid stent graft was applied in all FET animals. Regional SCBF was measured 4 times: (i) before cardiopulmonary bypass, (ii) after 1 h, (iii) after 3 h, and (iv) after 6 h of reperfusion using fluorescence microspheres. Spinal cord segments were examined histopathologically and by immunohistochemistry.
RESULTS
SCBF in FET decreased significantly from 0.13 ± 0.03 to 0.05 ± 0.02 ml/min/g after 1 h (P = 0.047). While at 3 h of reperfusion, SCBF increased and was comparable to baseline (0.09 ± 0.01 ml/min/g), beyond this time SCBF decreased again (0.05 ± 0.02 ml/min/g). A similar trend was found for SCBF in the cET group (baseline: 0.16 ± 0.04 ml/min/g, 1 h reperfusion: 0.02 ± 0.01 ml/min/g, 3 h reperfusion: 0.03 ± 0.01 ml/min/g and 6 h reperfusion: 0.02 ± 0.01 ml/min/g, P = 0.019). Cervical, thoracic and lumbar SCBF were also comparable in both groups. Histological analyses of spinal cord showed no differences in necrosis between cET and FET, while no differences were found for hypoxia-inducible factor-1α and apoptosis-inducing factor. In contrast, oxidative stress and caspase-induced apoptosis were higher in cET versus FET.
CONCLUSIONS
The SCBF changed significantly during extensive aortic arch surgery with circulatory arrest and moderate hypothermia, but such changes were comparable between the FET and cET groups. The implantation of hybrid stent graft did not influence SCBF in thoracic and lumbar segments of the spinal cord. The immunohistological examination showed no differences between cET and FET regarding ischaemic damage and hypoxia-induced effects in spinal cord segments.</description><identifier>ISSN: 1010-7940</identifier><identifier>EISSN: 1873-734X</identifier><identifier>DOI: 10.1093/ejcts/ezx085</identifier><identifier>PMID: 28525553</identifier><language>eng</language><publisher>Germany: Oxford University Press</publisher><ispartof>European journal of cardio-thoracic surgery, 2017-09, Vol.52 (3), p.485-491</ispartof><rights>The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved. 2017</rights><rights>The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c361t-d656a8f60186db6c6126af199735ec7a40af77cba221505f3e0e631456ff7a73</citedby><cites>FETCH-LOGICAL-c361t-d656a8f60186db6c6126af199735ec7a40af77cba221505f3e0e631456ff7a73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1578,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28525553$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Leontyev, Sergey</creatorcontrib><creatorcontrib>Dieterlen, Maja-Theresa</creatorcontrib><creatorcontrib>Halling, Michelle</creatorcontrib><creatorcontrib>Schlegel, Franziska</creatorcontrib><creatorcontrib>Hoyer, Alexandro</creatorcontrib><creatorcontrib>Ossmann, Susann</creatorcontrib><creatorcontrib>Klaeske, Kerstin</creatorcontrib><creatorcontrib>Etz, Christian D.</creatorcontrib><creatorcontrib>Mohr, Friedrich W.</creatorcontrib><title>Evaluation of conventional and frozen elephant trunk techniques on spinal cord blood flow in an animal model</title><title>European journal of cardio-thoracic surgery</title><addtitle>Eur J Cardiothorac Surg</addtitle><description>Abstract
OBJECTIVES
The treatment of patients with extensive thoracic aortic disease involving the arch and descending aorta is often performed using the frozen elephant trunk technique (FET). Spinal cord blood flow (SCBF) in cervical, thoracic and lumbar sections prior, during and after aortic arch surgery were compared in conventional elephant trunk (cET) and FET technique in a pig model.
METHODS
German Landrace pigs (75–85 kg) underwent aortic arch surgery using the FET (n = 8) or cET (n = 8) techniques. The E-vita Open hybrid stent graft was applied in all FET animals. Regional SCBF was measured 4 times: (i) before cardiopulmonary bypass, (ii) after 1 h, (iii) after 3 h, and (iv) after 6 h of reperfusion using fluorescence microspheres. Spinal cord segments were examined histopathologically and by immunohistochemistry.
RESULTS
SCBF in FET decreased significantly from 0.13 ± 0.03 to 0.05 ± 0.02 ml/min/g after 1 h (P = 0.047). While at 3 h of reperfusion, SCBF increased and was comparable to baseline (0.09 ± 0.01 ml/min/g), beyond this time SCBF decreased again (0.05 ± 0.02 ml/min/g). A similar trend was found for SCBF in the cET group (baseline: 0.16 ± 0.04 ml/min/g, 1 h reperfusion: 0.02 ± 0.01 ml/min/g, 3 h reperfusion: 0.03 ± 0.01 ml/min/g and 6 h reperfusion: 0.02 ± 0.01 ml/min/g, P = 0.019). Cervical, thoracic and lumbar SCBF were also comparable in both groups. Histological analyses of spinal cord showed no differences in necrosis between cET and FET, while no differences were found for hypoxia-inducible factor-1α and apoptosis-inducing factor. In contrast, oxidative stress and caspase-induced apoptosis were higher in cET versus FET.
CONCLUSIONS
The SCBF changed significantly during extensive aortic arch surgery with circulatory arrest and moderate hypothermia, but such changes were comparable between the FET and cET groups. The implantation of hybrid stent graft did not influence SCBF in thoracic and lumbar segments of the spinal cord. The immunohistological examination showed no differences between cET and FET regarding ischaemic damage and hypoxia-induced effects in spinal cord segments.</description><issn>1010-7940</issn><issn>1873-734X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9kL1PwzAQxS0EoqWwMSNvMBBqx7GdjKgqH1Illg5skeuc1RTXDnFSoH89Li2MSCfdne53T08PoUtK7igp2BhWugtj2H6SnB-hIc0lSyTLXo_jTChJZJGRAToLYUUIESyVp2iQ5jzlnLMhstONsr3qau-wN1h7twG325TFylXYtH4LDoOFZqlch7u2d2-4A7109XsPAce_0NQ7XPu2wgvrffyy_gPXLirEqtfxuPYV2HN0YpQNcHHoIzR_mM4nT8ns5fF5cj9LNBO0SyrBhcqNIDQX1UJoQVOhDC0KyThoqTKijJR6odKUcsINAwKC0YwLY6SSbIRu9rJN63ceu3JdBw3WKge-DyUtCMlZljIR0ds9qlsfQgumbNrot_0qKSl38ZY_8Zb7eCN-dVDuF2uo_uDfPCNwvQd83_wv9Q28UIar</recordid><startdate>20170901</startdate><enddate>20170901</enddate><creator>Leontyev, Sergey</creator><creator>Dieterlen, Maja-Theresa</creator><creator>Halling, Michelle</creator><creator>Schlegel, Franziska</creator><creator>Hoyer, Alexandro</creator><creator>Ossmann, Susann</creator><creator>Klaeske, Kerstin</creator><creator>Etz, Christian D.</creator><creator>Mohr, Friedrich W.</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170901</creationdate><title>Evaluation of conventional and frozen elephant trunk techniques on spinal cord blood flow in an animal model</title><author>Leontyev, Sergey ; Dieterlen, Maja-Theresa ; Halling, Michelle ; Schlegel, Franziska ; Hoyer, Alexandro ; Ossmann, Susann ; Klaeske, Kerstin ; Etz, Christian D. ; Mohr, Friedrich W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c361t-d656a8f60186db6c6126af199735ec7a40af77cba221505f3e0e631456ff7a73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Leontyev, Sergey</creatorcontrib><creatorcontrib>Dieterlen, Maja-Theresa</creatorcontrib><creatorcontrib>Halling, Michelle</creatorcontrib><creatorcontrib>Schlegel, Franziska</creatorcontrib><creatorcontrib>Hoyer, Alexandro</creatorcontrib><creatorcontrib>Ossmann, Susann</creatorcontrib><creatorcontrib>Klaeske, Kerstin</creatorcontrib><creatorcontrib>Etz, Christian D.</creatorcontrib><creatorcontrib>Mohr, Friedrich W.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of cardio-thoracic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Leontyev, Sergey</au><au>Dieterlen, Maja-Theresa</au><au>Halling, Michelle</au><au>Schlegel, Franziska</au><au>Hoyer, Alexandro</au><au>Ossmann, Susann</au><au>Klaeske, Kerstin</au><au>Etz, Christian D.</au><au>Mohr, Friedrich W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of conventional and frozen elephant trunk techniques on spinal cord blood flow in an animal model</atitle><jtitle>European journal of cardio-thoracic surgery</jtitle><addtitle>Eur J Cardiothorac Surg</addtitle><date>2017-09-01</date><risdate>2017</risdate><volume>52</volume><issue>3</issue><spage>485</spage><epage>491</epage><pages>485-491</pages><issn>1010-7940</issn><eissn>1873-734X</eissn><abstract>Abstract
OBJECTIVES
The treatment of patients with extensive thoracic aortic disease involving the arch and descending aorta is often performed using the frozen elephant trunk technique (FET). Spinal cord blood flow (SCBF) in cervical, thoracic and lumbar sections prior, during and after aortic arch surgery were compared in conventional elephant trunk (cET) and FET technique in a pig model.
METHODS
German Landrace pigs (75–85 kg) underwent aortic arch surgery using the FET (n = 8) or cET (n = 8) techniques. The E-vita Open hybrid stent graft was applied in all FET animals. Regional SCBF was measured 4 times: (i) before cardiopulmonary bypass, (ii) after 1 h, (iii) after 3 h, and (iv) after 6 h of reperfusion using fluorescence microspheres. Spinal cord segments were examined histopathologically and by immunohistochemistry.
RESULTS
SCBF in FET decreased significantly from 0.13 ± 0.03 to 0.05 ± 0.02 ml/min/g after 1 h (P = 0.047). While at 3 h of reperfusion, SCBF increased and was comparable to baseline (0.09 ± 0.01 ml/min/g), beyond this time SCBF decreased again (0.05 ± 0.02 ml/min/g). A similar trend was found for SCBF in the cET group (baseline: 0.16 ± 0.04 ml/min/g, 1 h reperfusion: 0.02 ± 0.01 ml/min/g, 3 h reperfusion: 0.03 ± 0.01 ml/min/g and 6 h reperfusion: 0.02 ± 0.01 ml/min/g, P = 0.019). Cervical, thoracic and lumbar SCBF were also comparable in both groups. Histological analyses of spinal cord showed no differences in necrosis between cET and FET, while no differences were found for hypoxia-inducible factor-1α and apoptosis-inducing factor. In contrast, oxidative stress and caspase-induced apoptosis were higher in cET versus FET.
CONCLUSIONS
The SCBF changed significantly during extensive aortic arch surgery with circulatory arrest and moderate hypothermia, but such changes were comparable between the FET and cET groups. The implantation of hybrid stent graft did not influence SCBF in thoracic and lumbar segments of the spinal cord. The immunohistological examination showed no differences between cET and FET regarding ischaemic damage and hypoxia-induced effects in spinal cord segments.</abstract><cop>Germany</cop><pub>Oxford University Press</pub><pmid>28525553</pmid><doi>10.1093/ejcts/ezx085</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1010-7940 |
ispartof | European journal of cardio-thoracic surgery, 2017-09, Vol.52 (3), p.485-491 |
issn | 1010-7940 1873-734X |
language | eng |
recordid | cdi_proquest_miscellaneous_1900834236 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Oxford University Press Journals All Titles (1996-Current); Alma/SFX Local Collection |
title | Evaluation of conventional and frozen elephant trunk techniques on spinal cord blood flow in an animal model |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T06%3A37%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20conventional%20and%20frozen%20elephant%20trunk%20techniques%20on%20spinal%20cord%20blood%20flow%20in%20an%20animal%20model&rft.jtitle=European%20journal%20of%20cardio-thoracic%20surgery&rft.au=Leontyev,%20Sergey&rft.date=2017-09-01&rft.volume=52&rft.issue=3&rft.spage=485&rft.epage=491&rft.pages=485-491&rft.issn=1010-7940&rft.eissn=1873-734X&rft_id=info:doi/10.1093/ejcts/ezx085&rft_dat=%3Cproquest_cross%3E1900834236%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1900834236&rft_id=info:pmid/28525553&rft_oup_id=10.1093/ejcts/ezx085&rfr_iscdi=true |