Fatigue of Paralyzed and Control Thenar Muscles Induced by Variable or Constant Frequency Stimulation
1 The Miami Project to Cure Paralysis, Departments of Neurological Surgery, 2 Physiology and Biophysics, University of Miami School of Medicine, Miami, Florida 33136 Thomas, Christine K., Lisa Griffin, Sharlene Godfrey, Edith Ribot-Ciscar, and Jane E. Butler. Fatigue of Paralyzed and Control The...
Gespeichert in:
Veröffentlicht in: | Journal of neurophysiology 2003-04, Vol.89 (4), p.2055-2064 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1 The Miami Project to Cure Paralysis,
Departments of Neurological Surgery, 2 Physiology
and Biophysics, University of Miami School of Medicine, Miami, Florida
33136
Thomas, Christine K.,
Lisa Griffin,
Sharlene Godfrey,
Edith Ribot-Ciscar, and
Jane E. Butler.
Fatigue of Paralyzed and Control Thenar Muscles Induced by
Variable or Constant Frequency Stimulation. J. Neurophysiol. 89: 2055-2064, 2003. Muscles paralyzed by chronic
(>1 yr) spinal cord injury fatigue readily. Our aim was to evaluate
whether the fatigability of paralyzed thenar muscles
( n = 10) could be reduced by the repeated delivery
of variable versus constant frequency pulse trains. Fatigue was induced
in four ways. Intermittent supramaximal median nerve stimulation
(300-ms-duration trains) was delivered at 1 ) constant high frequency (13 pulses at 40 Hz each second for 2 min);
2 ) variable high frequency (each second for 2 min). The
first two intervals of each variable frequency train were 5 and 20 ms.
The remaining pulses were evenly distributed in time across 275 ms. The
number of pulses varied for each subject such that the force time
integral in the unfatigued state matched that evoked by a constant
40-Hz train; 3 ) constant low frequency (7 pulses at 20 Hz each second for 4 min); and 4 ) variable low frequency
(each second for 4 min). The pulse pattern was the same as that for variable high frequency except that the force-time integral was matched
to that produced by the constant low-frequency stimulation. These same
experiments were performed on the thenar muscles of five able-bodied
control subjects. The variable high-frequency trains used to fatigue
paralyzed and control muscles had an average (± SE) of 12 ± 2 and 10 ± 1 pulses, respectively. Variable low-frequency trains
had 7 ± 1 and 6 ± 1 pulses, respectively. Significant mean force declines of comparable magnitude (to 20-25% initial fatigue force or to 13-21% initial 50 Hz force) were seen in paralyzed muscles with all four stimulation protocols. The force reductions in
paralyzed muscles were always accompanied by significant increases in
half-relaxation time and decreases in force-time integral, irrespective
of the stimulation protocol. Significant force decreases also occurred
in control muscles during each fatigue test. Again, these force
declines were similar whether constant or variable pulse patterns were
used at high or low frequencies (to 40-60% initial fatigue force or
to 29-36% initial 50 Hz force). The force red |
---|---|
ISSN: | 0022-3077 1522-1598 |
DOI: | 10.1152/jn.01002.2002 |