Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue

Purpose To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. Materials and Methods Model data simulations relevant to brain and low-perfuse...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2017-05, Vol.45 (5), p.spcone-spcone
Hauptverfasser: Meeus, Emma M., Novak, Jan, Withey, Stephanie B., Zarinabad, Niloufar, Dehghani, Hamid, Peet, Andrew C.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page spcone
container_issue 5
container_start_page spcone
container_title Journal of magnetic resonance imaging
container_volume 45
creator Meeus, Emma M.
Novak, Jan
Withey, Stephanie B.
Zarinabad, Niloufar
Dehghani, Hamid
Peet, Andrew C.
description Purpose To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. Materials and Methods Model data simulations relevant to brain and low-perfused tumor tissues were computed to assess the accuracy, relative bias, and reproducibility (CV%) of the fitting methods in estimating the IVIM parameters. The simulations were performed at a series of signal-to-noise ratio (SNR) levels to assess the influence of noise on the fitting. Results The estimated IVIM parameters from model simulations were found significantly different (P
doi_str_mv 10.1002/jmri.25730
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1891885506</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1891885506</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1040-1e322b9bc8e05961ea48ca6570edebd0c1ec940096a89a29c7807d24623cd7023</originalsourceid><addsrcrecordid>eNotkE1OwzAQhS0EEqWw4QRZIqSUsRMn9hJV5UeqxAJYW44zoa6SuNhOgR1H4IychLRlNU-aT09PHyGXFGYUgN2sO29njJcZHJEJ5YyljIvieMzAs5QKKE_JWQhrAJAy5xPyvNjqdtDRuj5xTWL76PXWfWI7RuNW6LGPSef2_8bGaPu3pMO4cnUYiaR1H7_fPxv0zRCwTqINYcBzctLoNuDF_52S17vFy_whXT7dP85vl6mhkENKMWOskpURCFwWFHUujC54CVhjVYOhaGQ-Di20kJpJU47za5YXLDN1CSybkqtD78a79wFDVJ0NBttW9-iGoKiQVAjOoRjR6wNqvAvBY6M23nbafykKamdO7cypvbnsD2gxY3U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1891885506</pqid></control><display><type>article</type><title>Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Wiley Online Library Free Content</source><creator>Meeus, Emma M. ; Novak, Jan ; Withey, Stephanie B. ; Zarinabad, Niloufar ; Dehghani, Hamid ; Peet, Andrew C.</creator><creatorcontrib>Meeus, Emma M. ; Novak, Jan ; Withey, Stephanie B. ; Zarinabad, Niloufar ; Dehghani, Hamid ; Peet, Andrew C.</creatorcontrib><description>Purpose To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. Materials and Methods Model data simulations relevant to brain and low-perfused tumor tissues were computed to assess the accuracy, relative bias, and reproducibility (CV%) of the fitting methods in estimating the IVIM parameters. The simulations were performed at a series of signal-to-noise ratio (SNR) levels to assess the influence of noise on the fitting. Results The estimated IVIM parameters from model simulations were found significantly different (P&lt;0.05) using simultaneous and constrained fitting methods at low SNR. Higher accuracy and reproducibility were achieved with the constrained fitting method. Using this method, the mean error (%) for the estimated IVIM parameters at a clinically relevant SNR=40 were D 0.35, D* 41.0 and f 4.55 for the tumor model and D 1.87, D* 2.48, and f 7.49 for the gray matter model. The most robust parameters were the IVIM-D and IVIM-f. The IVIM-D* was increasingly overestimated at low perfusion. Conclusion A constrained IVIM fitting method provides more accurate and reproducible IVIM parameters in low-perfused tissue compared with simultaneous fitting. Level of Evidence: 3 J. MAGN. RESON. IMAGING 2017; 45:1325-1334</description><identifier>ISSN: 1053-1807</identifier><identifier>EISSN: 1522-2586</identifier><identifier>DOI: 10.1002/jmri.25730</identifier><language>eng</language><ispartof>Journal of magnetic resonance imaging, 2017-05, Vol.45 (5), p.spcone-spcone</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Meeus, Emma M.</creatorcontrib><creatorcontrib>Novak, Jan</creatorcontrib><creatorcontrib>Withey, Stephanie B.</creatorcontrib><creatorcontrib>Zarinabad, Niloufar</creatorcontrib><creatorcontrib>Dehghani, Hamid</creatorcontrib><creatorcontrib>Peet, Andrew C.</creatorcontrib><title>Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue</title><title>Journal of magnetic resonance imaging</title><description>Purpose To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. Materials and Methods Model data simulations relevant to brain and low-perfused tumor tissues were computed to assess the accuracy, relative bias, and reproducibility (CV%) of the fitting methods in estimating the IVIM parameters. The simulations were performed at a series of signal-to-noise ratio (SNR) levels to assess the influence of noise on the fitting. Results The estimated IVIM parameters from model simulations were found significantly different (P&lt;0.05) using simultaneous and constrained fitting methods at low SNR. Higher accuracy and reproducibility were achieved with the constrained fitting method. Using this method, the mean error (%) for the estimated IVIM parameters at a clinically relevant SNR=40 were D 0.35, D* 41.0 and f 4.55 for the tumor model and D 1.87, D* 2.48, and f 7.49 for the gray matter model. The most robust parameters were the IVIM-D and IVIM-f. The IVIM-D* was increasingly overestimated at low perfusion. Conclusion A constrained IVIM fitting method provides more accurate and reproducible IVIM parameters in low-perfused tissue compared with simultaneous fitting. Level of Evidence: 3 J. MAGN. RESON. IMAGING 2017; 45:1325-1334</description><issn>1053-1807</issn><issn>1522-2586</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNotkE1OwzAQhS0EEqWw4QRZIqSUsRMn9hJV5UeqxAJYW44zoa6SuNhOgR1H4IychLRlNU-aT09PHyGXFGYUgN2sO29njJcZHJEJ5YyljIvieMzAs5QKKE_JWQhrAJAy5xPyvNjqdtDRuj5xTWL76PXWfWI7RuNW6LGPSef2_8bGaPu3pMO4cnUYiaR1H7_fPxv0zRCwTqINYcBzctLoNuDF_52S17vFy_whXT7dP85vl6mhkENKMWOskpURCFwWFHUujC54CVhjVYOhaGQ-Di20kJpJU47za5YXLDN1CSybkqtD78a79wFDVJ0NBttW9-iGoKiQVAjOoRjR6wNqvAvBY6M23nbafykKamdO7cypvbnsD2gxY3U</recordid><startdate>201705</startdate><enddate>201705</enddate><creator>Meeus, Emma M.</creator><creator>Novak, Jan</creator><creator>Withey, Stephanie B.</creator><creator>Zarinabad, Niloufar</creator><creator>Dehghani, Hamid</creator><creator>Peet, Andrew C.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>201705</creationdate><title>Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue</title><author>Meeus, Emma M. ; Novak, Jan ; Withey, Stephanie B. ; Zarinabad, Niloufar ; Dehghani, Hamid ; Peet, Andrew C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1040-1e322b9bc8e05961ea48ca6570edebd0c1ec940096a89a29c7807d24623cd7023</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Meeus, Emma M.</creatorcontrib><creatorcontrib>Novak, Jan</creatorcontrib><creatorcontrib>Withey, Stephanie B.</creatorcontrib><creatorcontrib>Zarinabad, Niloufar</creatorcontrib><creatorcontrib>Dehghani, Hamid</creatorcontrib><creatorcontrib>Peet, Andrew C.</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Meeus, Emma M.</au><au>Novak, Jan</au><au>Withey, Stephanie B.</au><au>Zarinabad, Niloufar</au><au>Dehghani, Hamid</au><au>Peet, Andrew C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue</atitle><jtitle>Journal of magnetic resonance imaging</jtitle><date>2017-05</date><risdate>2017</risdate><volume>45</volume><issue>5</issue><spage>spcone</spage><epage>spcone</epage><pages>spcone-spcone</pages><issn>1053-1807</issn><eissn>1522-2586</eissn><abstract>Purpose To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. Materials and Methods Model data simulations relevant to brain and low-perfused tumor tissues were computed to assess the accuracy, relative bias, and reproducibility (CV%) of the fitting methods in estimating the IVIM parameters. The simulations were performed at a series of signal-to-noise ratio (SNR) levels to assess the influence of noise on the fitting. Results The estimated IVIM parameters from model simulations were found significantly different (P&lt;0.05) using simultaneous and constrained fitting methods at low SNR. Higher accuracy and reproducibility were achieved with the constrained fitting method. Using this method, the mean error (%) for the estimated IVIM parameters at a clinically relevant SNR=40 were D 0.35, D* 41.0 and f 4.55 for the tumor model and D 1.87, D* 2.48, and f 7.49 for the gray matter model. The most robust parameters were the IVIM-D and IVIM-f. The IVIM-D* was increasingly overestimated at low perfusion. Conclusion A constrained IVIM fitting method provides more accurate and reproducible IVIM parameters in low-perfused tissue compared with simultaneous fitting. Level of Evidence: 3 J. MAGN. RESON. IMAGING 2017; 45:1325-1334</abstract><doi>10.1002/jmri.25730</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1053-1807
ispartof Journal of magnetic resonance imaging, 2017-05, Vol.45 (5), p.spcone-spcone
issn 1053-1807
1522-2586
language eng
recordid cdi_proquest_miscellaneous_1891885506
source Wiley Online Library Journals Frontfile Complete; Wiley Online Library Free Content
title Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissue
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T08%3A12%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20intravoxel%20incoherent%20motion%20fitting%20methods%20in%20low%E2%80%90perfused%20tissue&rft.jtitle=Journal%20of%20magnetic%20resonance%20imaging&rft.au=Meeus,%20Emma%20M.&rft.date=2017-05&rft.volume=45&rft.issue=5&rft.spage=spcone&rft.epage=spcone&rft.pages=spcone-spcone&rft.issn=1053-1807&rft.eissn=1522-2586&rft_id=info:doi/10.1002/jmri.25730&rft_dat=%3Cproquest_cross%3E1891885506%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1891885506&rft_id=info:pmid/&rfr_iscdi=true