Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences
•Bilayer glucose biosensor with permselective layer for interference reduction.•Rejects interferences from ascorbic acid, glycine, glutamic acid and uric acid.•Highly stable reponse for more than 2months.•Wide linear range of 0.5–24mM and a detection limit of 26.9μM.•Enabled reliable glucose determi...
Gespeichert in:
Veröffentlicht in: | Food chemistry 2017-08, Vol.229, p.127-135 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 135 |
---|---|
container_issue | |
container_start_page | 127 |
container_title | Food chemistry |
container_volume | 229 |
creator | Ayenimo, Joseph G. Adeloju, Samuel B. |
description | •Bilayer glucose biosensor with permselective layer for interference reduction.•Rejects interferences from ascorbic acid, glycine, glutamic acid and uric acid.•Highly stable reponse for more than 2months.•Wide linear range of 0.5–24mM and a detection limit of 26.9μM.•Enabled reliable glucose determination in fruit juices and non-alcoholic beverages.
A novel polypyrrole (PPy)-based bilayer amperometric glucose biosensor integrated with a permselective layer has been developed for detection of glucose in the presence of interferences. It comprises of a PPy-GOx film grown, in the absence of electrolyte, as an inner layer, and a permselective PPy-Cl film as an outer layer. The PPy-GOx/PPy-Cl bilayer biosensor was effective in rejecting 98% of ascorbic acid and 100% of glycine, glutamic acid and uric acid. With an outer layer thickness of 6.6nm, the bilayer biosensor gave nearly identical glucose response to that of a single layer PPy-GOx biosensor. The biosensor also exhibited good reproducibility (1.9% rsd, n=10), high stability (more than 2months), wide linear range (0.5–24mM), low Km (8.4mM), high Imax (77.2μAcm−2), low detection limit (26.9μM) and good sensitivity (3.5μAcm−2mM−1). The bilayer biosensor was successfully employed for glucose determination in various fruit juices. |
doi_str_mv | 10.1016/j.foodchem.2017.01.138 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1884170487</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0308814617301504</els_id><sourcerecordid>1884170487</sourcerecordid><originalsourceid>FETCH-LOGICAL-c405t-1436924e3c4e85759ec9232a8f54e011a1d2aebff6f14cb36d2f6ae57f4026643</originalsourceid><addsrcrecordid>eNqFkc1u1DAUhS0EosPAK1ResknwXxzPjqqigFSJDawtx7luPXLiYDuFeRMeF0czZcvqLu537tE9B6FrSlpKqPxwbF2Mo32EqWWE9i2hLeXqBdpR1fOmJz17iXaEE9UoKuQVepPzkRBSWfUaXTHFe0a7bof-3EwLpDhBSd7iEQrY4uOMo8MPYbUxA_Yzdmn1BR9XbyHjX7484iWG03JKKQZoBpNhxIOv8JxjOgNmrsICD8mUuqweU4awHX8CHMwJEnYVhd82rPliuPHJQYK52rxFr5wJGd5d5h79uPv0_fZLc__t89fbm_vGCtKVhgouD0wAtwJU13cHsAfGmVGuE0AoNXRkBgbnpKPCDlyOzEkDXe8EYVIKvkfvz3eXFH-ukIuefLYQgpkhrllTpQTtiaix7pE8ozbFnBM4vSQ_mXTSlOitFX3Uz63orRVNqK6tVOH1xWMdJhj_yZ5rqMDHMwD10ycPSWfrtxhGn2pmeoz-fx5_ASMBphc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1884170487</pqid></control><display><type>article</type><title>Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Ayenimo, Joseph G. ; Adeloju, Samuel B.</creator><creatorcontrib>Ayenimo, Joseph G. ; Adeloju, Samuel B.</creatorcontrib><description>•Bilayer glucose biosensor with permselective layer for interference reduction.•Rejects interferences from ascorbic acid, glycine, glutamic acid and uric acid.•Highly stable reponse for more than 2months.•Wide linear range of 0.5–24mM and a detection limit of 26.9μM.•Enabled reliable glucose determination in fruit juices and non-alcoholic beverages.
A novel polypyrrole (PPy)-based bilayer amperometric glucose biosensor integrated with a permselective layer has been developed for detection of glucose in the presence of interferences. It comprises of a PPy-GOx film grown, in the absence of electrolyte, as an inner layer, and a permselective PPy-Cl film as an outer layer. The PPy-GOx/PPy-Cl bilayer biosensor was effective in rejecting 98% of ascorbic acid and 100% of glycine, glutamic acid and uric acid. With an outer layer thickness of 6.6nm, the bilayer biosensor gave nearly identical glucose response to that of a single layer PPy-GOx biosensor. The biosensor also exhibited good reproducibility (1.9% rsd, n=10), high stability (more than 2months), wide linear range (0.5–24mM), low Km (8.4mM), high Imax (77.2μAcm−2), low detection limit (26.9μM) and good sensitivity (3.5μAcm−2mM−1). The bilayer biosensor was successfully employed for glucose determination in various fruit juices.</description><identifier>ISSN: 0308-8146</identifier><identifier>EISSN: 1873-7072</identifier><identifier>DOI: 10.1016/j.foodchem.2017.01.138</identifier><identifier>PMID: 28372155</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Amperometry ; Beverages - analysis ; Biosensing Techniques - methods ; Biosensor ; Fruit and Vegetable Juices - analysis ; Fruit juices ; Glucose ; Glucose - analysis ; Glucose - chemistry ; Glucose oxidase ; Non-alcoholic beverages ; Polymers - chemistry ; Polypyrrole ; Pyrroles - chemistry</subject><ispartof>Food chemistry, 2017-08, Vol.229, p.127-135</ispartof><rights>2017 Elsevier Ltd</rights><rights>Copyright © 2017 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c405t-1436924e3c4e85759ec9232a8f54e011a1d2aebff6f14cb36d2f6ae57f4026643</citedby><cites>FETCH-LOGICAL-c405t-1436924e3c4e85759ec9232a8f54e011a1d2aebff6f14cb36d2f6ae57f4026643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.foodchem.2017.01.138$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28372155$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ayenimo, Joseph G.</creatorcontrib><creatorcontrib>Adeloju, Samuel B.</creatorcontrib><title>Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences</title><title>Food chemistry</title><addtitle>Food Chem</addtitle><description>•Bilayer glucose biosensor with permselective layer for interference reduction.•Rejects interferences from ascorbic acid, glycine, glutamic acid and uric acid.•Highly stable reponse for more than 2months.•Wide linear range of 0.5–24mM and a detection limit of 26.9μM.•Enabled reliable glucose determination in fruit juices and non-alcoholic beverages.
A novel polypyrrole (PPy)-based bilayer amperometric glucose biosensor integrated with a permselective layer has been developed for detection of glucose in the presence of interferences. It comprises of a PPy-GOx film grown, in the absence of electrolyte, as an inner layer, and a permselective PPy-Cl film as an outer layer. The PPy-GOx/PPy-Cl bilayer biosensor was effective in rejecting 98% of ascorbic acid and 100% of glycine, glutamic acid and uric acid. With an outer layer thickness of 6.6nm, the bilayer biosensor gave nearly identical glucose response to that of a single layer PPy-GOx biosensor. The biosensor also exhibited good reproducibility (1.9% rsd, n=10), high stability (more than 2months), wide linear range (0.5–24mM), low Km (8.4mM), high Imax (77.2μAcm−2), low detection limit (26.9μM) and good sensitivity (3.5μAcm−2mM−1). The bilayer biosensor was successfully employed for glucose determination in various fruit juices.</description><subject>Amperometry</subject><subject>Beverages - analysis</subject><subject>Biosensing Techniques - methods</subject><subject>Biosensor</subject><subject>Fruit and Vegetable Juices - analysis</subject><subject>Fruit juices</subject><subject>Glucose</subject><subject>Glucose - analysis</subject><subject>Glucose - chemistry</subject><subject>Glucose oxidase</subject><subject>Non-alcoholic beverages</subject><subject>Polymers - chemistry</subject><subject>Polypyrrole</subject><subject>Pyrroles - chemistry</subject><issn>0308-8146</issn><issn>1873-7072</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkc1u1DAUhS0EosPAK1ResknwXxzPjqqigFSJDawtx7luPXLiYDuFeRMeF0czZcvqLu537tE9B6FrSlpKqPxwbF2Mo32EqWWE9i2hLeXqBdpR1fOmJz17iXaEE9UoKuQVepPzkRBSWfUaXTHFe0a7bof-3EwLpDhBSd7iEQrY4uOMo8MPYbUxA_Yzdmn1BR9XbyHjX7484iWG03JKKQZoBpNhxIOv8JxjOgNmrsICD8mUuqweU4awHX8CHMwJEnYVhd82rPliuPHJQYK52rxFr5wJGd5d5h79uPv0_fZLc__t89fbm_vGCtKVhgouD0wAtwJU13cHsAfGmVGuE0AoNXRkBgbnpKPCDlyOzEkDXe8EYVIKvkfvz3eXFH-ukIuefLYQgpkhrllTpQTtiaix7pE8ozbFnBM4vSQ_mXTSlOitFX3Uz63orRVNqK6tVOH1xWMdJhj_yZ5rqMDHMwD10ycPSWfrtxhGn2pmeoz-fx5_ASMBphc</recordid><startdate>20170815</startdate><enddate>20170815</enddate><creator>Ayenimo, Joseph G.</creator><creator>Adeloju, Samuel B.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170815</creationdate><title>Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences</title><author>Ayenimo, Joseph G. ; Adeloju, Samuel B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c405t-1436924e3c4e85759ec9232a8f54e011a1d2aebff6f14cb36d2f6ae57f4026643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Amperometry</topic><topic>Beverages - analysis</topic><topic>Biosensing Techniques - methods</topic><topic>Biosensor</topic><topic>Fruit and Vegetable Juices - analysis</topic><topic>Fruit juices</topic><topic>Glucose</topic><topic>Glucose - analysis</topic><topic>Glucose - chemistry</topic><topic>Glucose oxidase</topic><topic>Non-alcoholic beverages</topic><topic>Polymers - chemistry</topic><topic>Polypyrrole</topic><topic>Pyrroles - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ayenimo, Joseph G.</creatorcontrib><creatorcontrib>Adeloju, Samuel B.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Food chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ayenimo, Joseph G.</au><au>Adeloju, Samuel B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences</atitle><jtitle>Food chemistry</jtitle><addtitle>Food Chem</addtitle><date>2017-08-15</date><risdate>2017</risdate><volume>229</volume><spage>127</spage><epage>135</epage><pages>127-135</pages><issn>0308-8146</issn><eissn>1873-7072</eissn><abstract>•Bilayer glucose biosensor with permselective layer for interference reduction.•Rejects interferences from ascorbic acid, glycine, glutamic acid and uric acid.•Highly stable reponse for more than 2months.•Wide linear range of 0.5–24mM and a detection limit of 26.9μM.•Enabled reliable glucose determination in fruit juices and non-alcoholic beverages.
A novel polypyrrole (PPy)-based bilayer amperometric glucose biosensor integrated with a permselective layer has been developed for detection of glucose in the presence of interferences. It comprises of a PPy-GOx film grown, in the absence of electrolyte, as an inner layer, and a permselective PPy-Cl film as an outer layer. The PPy-GOx/PPy-Cl bilayer biosensor was effective in rejecting 98% of ascorbic acid and 100% of glycine, glutamic acid and uric acid. With an outer layer thickness of 6.6nm, the bilayer biosensor gave nearly identical glucose response to that of a single layer PPy-GOx biosensor. The biosensor also exhibited good reproducibility (1.9% rsd, n=10), high stability (more than 2months), wide linear range (0.5–24mM), low Km (8.4mM), high Imax (77.2μAcm−2), low detection limit (26.9μM) and good sensitivity (3.5μAcm−2mM−1). The bilayer biosensor was successfully employed for glucose determination in various fruit juices.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>28372155</pmid><doi>10.1016/j.foodchem.2017.01.138</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0308-8146 |
ispartof | Food chemistry, 2017-08, Vol.229, p.127-135 |
issn | 0308-8146 1873-7072 |
language | eng |
recordid | cdi_proquest_miscellaneous_1884170487 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Amperometry Beverages - analysis Biosensing Techniques - methods Biosensor Fruit and Vegetable Juices - analysis Fruit juices Glucose Glucose - analysis Glucose - chemistry Glucose oxidase Non-alcoholic beverages Polymers - chemistry Polypyrrole Pyrroles - chemistry |
title | Amperometric detection of glucose in fruit juices with polypyrrole-based biosensor with an integrated permselective layer for exclusion of interferences |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T12%3A18%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Amperometric%20detection%20of%20glucose%20in%20fruit%20juices%20with%20polypyrrole-based%20biosensor%20with%20an%20integrated%20permselective%20layer%20for%20exclusion%20of%20interferences&rft.jtitle=Food%20chemistry&rft.au=Ayenimo,%20Joseph%20G.&rft.date=2017-08-15&rft.volume=229&rft.spage=127&rft.epage=135&rft.pages=127-135&rft.issn=0308-8146&rft.eissn=1873-7072&rft_id=info:doi/10.1016/j.foodchem.2017.01.138&rft_dat=%3Cproquest_cross%3E1884170487%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1884170487&rft_id=info:pmid/28372155&rft_els_id=S0308814617301504&rfr_iscdi=true |