Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders
Polarimetry plays an important role in the measurement of solar magnetic fields. We devel- oped a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibrati...
Gespeichert in:
Veröffentlicht in: | Research in astronomy and astrophysics 2017, Vol.17 (1), p.87-96 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 96 |
---|---|
container_issue | 1 |
container_start_page | 87 |
container_title | Research in astronomy and astrophysics |
container_volume | 17 |
creator | Guo, Jing Ren, De-Qing Liu, Cheng-Chao Zhu, Yong-Tian Dou, Jiang-Pei Zhang, Xi Beck, Christian |
description | Polarimetry plays an important role in the measurement of solar magnetic fields. We devel- oped a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibration methods are discussed in detail. The azimuth error of the transmission axis of the polarizer as well as the fast axes of the two LCVRs and the quarter-wave plate were determined using dedicated procedures. Linearly and circularly polarized light were employed to evaluate the performance of the HHP. The experimental results indicate that a polarimetric sensitivity of better than 5.7 × 10-3 can be achieved by using a single short-exposure image, while an accuracy on the order of 10-5 can be reached by using a large number of short-exposure images. This makes the HHP a high-performance system that can be used with a ground-based solar telescope for high-precision solar magnetic field investigations. |
doi_str_mv | 10.1088/1674-4527/17/1/8 |
format | Article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_miscellaneous_1884127177</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>671276890</cqvip_id><sourcerecordid>1877818328</sourcerecordid><originalsourceid>FETCH-LOGICAL-c415t-ee007922fd231c4c8c58868778e098d5b24b277127ade1cf1a18b4350f754b763</originalsourceid><addsrcrecordid>eNqNkb1rwzAQxUVpoWnavaPo1KFuJPlD8ljSTwh0aWchy2dHwbEcyS74v6-chIylcHBw-r173BNCt5Q8UiLEgmY8iZKU8QUNtRBnaMbinEcZI_k5mp2eL9GV9xtCsjTN2AwNz-BN3WLVllirxhRO9ca22FZY4bWp15GH1pve_Jh-3FP7odJ6cEqPuLONcmYLPThcKA8lDuLG7AYT9rnR96rBP4FQRQPYQa9cCc5fo4tKNR5ujn2Ovl9fvpbv0erz7WP5tIp0QtM-AiCE54xVJYupTrTQqRCZ4FwAyUWZFiwpGOeUcVUC1RVVVBRJnJKKp0nBs3iO7g97O2d3A_hebo3X0DSqBTt4SYVIgppy_g802FIRMxFQckC1s947qGQXIlBulJTI6TPklLac0pY0lJwkDweJsZ3c2MG14ey_8Lujw9q29c609ckim87NRE7iX3tSliA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1877818328</pqid></control><display><type>article</type><title>Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders</title><source>IOP Publishing Journals</source><source>Alma/SFX Local Collection</source><creator>Guo, Jing ; Ren, De-Qing ; Liu, Cheng-Chao ; Zhu, Yong-Tian ; Dou, Jiang-Pei ; Zhang, Xi ; Beck, Christian</creator><creatorcontrib>Guo, Jing ; Ren, De-Qing ; Liu, Cheng-Chao ; Zhu, Yong-Tian ; Dou, Jiang-Pei ; Zhang, Xi ; Beck, Christian</creatorcontrib><description>Polarimetry plays an important role in the measurement of solar magnetic fields. We devel- oped a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibration methods are discussed in detail. The azimuth error of the transmission axis of the polarizer as well as the fast axes of the two LCVRs and the quarter-wave plate were determined using dedicated procedures. Linearly and circularly polarized light were employed to evaluate the performance of the HHP. The experimental results indicate that a polarimetric sensitivity of better than 5.7 × 10-3 can be achieved by using a single short-exposure image, while an accuracy on the order of 10-5 can be reached by using a large number of short-exposure images. This makes the HHP a high-performance system that can be used with a ground-based solar telescope for high-precision solar magnetic field investigations.</description><identifier>ISSN: 1674-4527</identifier><identifier>EISSN: 2397-6209</identifier><identifier>DOI: 10.1088/1674-4527/17/1/8</identifier><language>eng</language><publisher>National Astronomical Observatories, CAS and IOP Publishing Ltd</publisher><subject>Astronomical polarimetry ; Calibration ; Liquid crystals ; Nematic crystals ; Polarimeters ; Retarders ; Solar magnetic field ; 可变 ; 旋光仪 ; 液晶 ; 相位延迟器 ; 设计 ; 高性能系统 ; 高灵敏度 ; 高精度</subject><ispartof>Research in astronomy and astrophysics, 2017, Vol.17 (1), p.87-96</ispartof><rights>2017 National Astronomical Observatories, CAS and IOP Publishing Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c415t-ee007922fd231c4c8c58868778e098d5b24b277127ade1cf1a18b4350f754b763</citedby><cites>FETCH-LOGICAL-c415t-ee007922fd231c4c8c58868778e098d5b24b277127ade1cf1a18b4350f754b763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/94947C/94947C.jpg</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1674-4527/17/1/8/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,4024,27923,27924,27925,53846</link.rule.ids></links><search><creatorcontrib>Guo, Jing</creatorcontrib><creatorcontrib>Ren, De-Qing</creatorcontrib><creatorcontrib>Liu, Cheng-Chao</creatorcontrib><creatorcontrib>Zhu, Yong-Tian</creatorcontrib><creatorcontrib>Dou, Jiang-Pei</creatorcontrib><creatorcontrib>Zhang, Xi</creatorcontrib><creatorcontrib>Beck, Christian</creatorcontrib><title>Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders</title><title>Research in astronomy and astrophysics</title><addtitle>Chinese Journal of Astronomy and Astrophysics</addtitle><description>Polarimetry plays an important role in the measurement of solar magnetic fields. We devel- oped a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibration methods are discussed in detail. The azimuth error of the transmission axis of the polarizer as well as the fast axes of the two LCVRs and the quarter-wave plate were determined using dedicated procedures. Linearly and circularly polarized light were employed to evaluate the performance of the HHP. The experimental results indicate that a polarimetric sensitivity of better than 5.7 × 10-3 can be achieved by using a single short-exposure image, while an accuracy on the order of 10-5 can be reached by using a large number of short-exposure images. This makes the HHP a high-performance system that can be used with a ground-based solar telescope for high-precision solar magnetic field investigations.</description><subject>Astronomical polarimetry</subject><subject>Calibration</subject><subject>Liquid crystals</subject><subject>Nematic crystals</subject><subject>Polarimeters</subject><subject>Retarders</subject><subject>Solar magnetic field</subject><subject>可变</subject><subject>旋光仪</subject><subject>液晶</subject><subject>相位延迟器</subject><subject>设计</subject><subject>高性能系统</subject><subject>高灵敏度</subject><subject>高精度</subject><issn>1674-4527</issn><issn>2397-6209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNkb1rwzAQxUVpoWnavaPo1KFuJPlD8ljSTwh0aWchy2dHwbEcyS74v6-chIylcHBw-r173BNCt5Q8UiLEgmY8iZKU8QUNtRBnaMbinEcZI_k5mp2eL9GV9xtCsjTN2AwNz-BN3WLVllirxhRO9ca22FZY4bWp15GH1pve_Jh-3FP7odJ6cEqPuLONcmYLPThcKA8lDuLG7AYT9rnR96rBP4FQRQPYQa9cCc5fo4tKNR5ujn2Ovl9fvpbv0erz7WP5tIp0QtM-AiCE54xVJYupTrTQqRCZ4FwAyUWZFiwpGOeUcVUC1RVVVBRJnJKKp0nBs3iO7g97O2d3A_hebo3X0DSqBTt4SYVIgppy_g802FIRMxFQckC1s947qGQXIlBulJTI6TPklLac0pY0lJwkDweJsZ3c2MG14ey_8Lujw9q29c609ckim87NRE7iX3tSliA</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Guo, Jing</creator><creator>Ren, De-Qing</creator><creator>Liu, Cheng-Chao</creator><creator>Zhu, Yong-Tian</creator><creator>Dou, Jiang-Pei</creator><creator>Zhang, Xi</creator><creator>Beck, Christian</creator><general>National Astronomical Observatories, CAS and IOP Publishing Ltd</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W94</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TG</scope><scope>KL.</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>2017</creationdate><title>Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders</title><author>Guo, Jing ; Ren, De-Qing ; Liu, Cheng-Chao ; Zhu, Yong-Tian ; Dou, Jiang-Pei ; Zhang, Xi ; Beck, Christian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c415t-ee007922fd231c4c8c58868778e098d5b24b277127ade1cf1a18b4350f754b763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Astronomical polarimetry</topic><topic>Calibration</topic><topic>Liquid crystals</topic><topic>Nematic crystals</topic><topic>Polarimeters</topic><topic>Retarders</topic><topic>Solar magnetic field</topic><topic>可变</topic><topic>旋光仪</topic><topic>液晶</topic><topic>相位延迟器</topic><topic>设计</topic><topic>高性能系统</topic><topic>高灵敏度</topic><topic>高精度</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Guo, Jing</creatorcontrib><creatorcontrib>Ren, De-Qing</creatorcontrib><creatorcontrib>Liu, Cheng-Chao</creatorcontrib><creatorcontrib>Zhu, Yong-Tian</creatorcontrib><creatorcontrib>Dou, Jiang-Pei</creatorcontrib><creatorcontrib>Zhang, Xi</creatorcontrib><creatorcontrib>Beck, Christian</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-自然科学</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Meteorological & Geoastrophysical Abstracts</collection><collection>Meteorological & Geoastrophysical Abstracts - Academic</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Research in astronomy and astrophysics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Guo, Jing</au><au>Ren, De-Qing</au><au>Liu, Cheng-Chao</au><au>Zhu, Yong-Tian</au><au>Dou, Jiang-Pei</au><au>Zhang, Xi</au><au>Beck, Christian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders</atitle><jtitle>Research in astronomy and astrophysics</jtitle><addtitle>Chinese Journal of Astronomy and Astrophysics</addtitle><date>2017</date><risdate>2017</risdate><volume>17</volume><issue>1</issue><spage>87</spage><epage>96</epage><pages>87-96</pages><issn>1674-4527</issn><eissn>2397-6209</eissn><abstract>Polarimetry plays an important role in the measurement of solar magnetic fields. We devel- oped a high-sensitivity and high-accuracy polarimeter (HHP) based on nematic liquid crystal variable retarders (LCVRs), which has a compact setup and no mechanical moving parts. The system design and calibration methods are discussed in detail. The azimuth error of the transmission axis of the polarizer as well as the fast axes of the two LCVRs and the quarter-wave plate were determined using dedicated procedures. Linearly and circularly polarized light were employed to evaluate the performance of the HHP. The experimental results indicate that a polarimetric sensitivity of better than 5.7 × 10-3 can be achieved by using a single short-exposure image, while an accuracy on the order of 10-5 can be reached by using a large number of short-exposure images. This makes the HHP a high-performance system that can be used with a ground-based solar telescope for high-precision solar magnetic field investigations.</abstract><pub>National Astronomical Observatories, CAS and IOP Publishing Ltd</pub><doi>10.1088/1674-4527/17/1/8</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1674-4527 |
ispartof | Research in astronomy and astrophysics, 2017, Vol.17 (1), p.87-96 |
issn | 1674-4527 2397-6209 |
language | eng |
recordid | cdi_proquest_miscellaneous_1884127177 |
source | IOP Publishing Journals; Alma/SFX Local Collection |
subjects | Astronomical polarimetry Calibration Liquid crystals Nematic crystals Polarimeters Retarders Solar magnetic field 可变 旋光仪 液晶 相位延迟器 设计 高性能系统 高灵敏度 高精度 |
title | Design and calibration of a high-sensitivity and high-accuracy polarimeter based on liquid crystal variable retarders |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T04%3A01%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20calibration%20of%20a%20high-sensitivity%20and%20high-accuracy%20polarimeter%20based%20on%20liquid%20crystal%20variable%20retarders&rft.jtitle=Research%20in%20astronomy%20and%20astrophysics&rft.au=Guo,%20Jing&rft.date=2017&rft.volume=17&rft.issue=1&rft.spage=87&rft.epage=96&rft.pages=87-96&rft.issn=1674-4527&rft.eissn=2397-6209&rft_id=info:doi/10.1088/1674-4527/17/1/8&rft_dat=%3Cproquest_iop_j%3E1877818328%3C/proquest_iop_j%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1877818328&rft_id=info:pmid/&rft_cqvip_id=671276890&rfr_iscdi=true |