Hollow carbon spheres and a hollow carbon sphere/polyvinylpyrrolidone composite as ammonia sensors

This study reports on the ammonia vapour sensing behaviour of hollow carbon spheres (HCSs), a hollow carbon sphere-polyvinylpyrrolidone (HCS/PVP) composite and annealed hollow carbon spheres (in a humid environment). For device fabrication, a surfactant assisted method was used to homogeneously disp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of materials chemistry. A, Materials for energy and sustainability Materials for energy and sustainability, 2017, Vol.5 (6), p.2539-2549
Hauptverfasser: Mutuma, Bridget K, Rodrigues, Rafael, Ranganathan, Kamalakannan, Matsoso, Boitumelo, Wamwangi, Daniel, Huemmelgen, Ivo A, Coville, Neil J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2549
container_issue 6
container_start_page 2539
container_title Journal of materials chemistry. A, Materials for energy and sustainability
container_volume 5
creator Mutuma, Bridget K
Rodrigues, Rafael
Ranganathan, Kamalakannan
Matsoso, Boitumelo
Wamwangi, Daniel
Huemmelgen, Ivo A
Coville, Neil J
description This study reports on the ammonia vapour sensing behaviour of hollow carbon spheres (HCSs), a hollow carbon sphere-polyvinylpyrrolidone (HCS/PVP) composite and annealed hollow carbon spheres (in a humid environment). For device fabrication, a surfactant assisted method was used to homogeneously disperse the hollow carbon spheres onto an interdigitated electrode. Conductance measurements (sensor response and recovery time) were performed at 20 degree C and 40 degree C. The sensor response was investigated by varying both ammonia concentration and relative humidity. The presence of amorphous domains and oxygenated groups on the pristine hollow carbon spheres resulted in a high relative humidity response. However, the detection of ammonia at high relative humidity using the pristine hollow carbon spheres was found to be negligible due to the inhibition of ammonia adsorption sites by the high concentration of water molecules. In contrast, a decline in conductivity at high relative humidity was recorded in the HCS/PVP sensors due to polymer swelling and plasticization. Annealing of the hollow carbon spheres resulted in a decrease in the amorphous domains in the carbon structure and a subsequent increase in the surface area. The topology of the response was determined as a function of these two variables (NH3 and H2O concentration) and analysed by applying a generalized tristimulus analysis to allow the ammonia concentration to be determined independently of the relative humidity. The pristine HCS, HCS/PVP and annealed HCS sensor responses to 74 ppm NH3 at ambient humidity were 6%, 86% and 196%, respectively. The ammonia sensitivity values (% per ppm) of the pristine HCSs, HCS/PVP and annealed HCSs were 0.08, 4 and 1.6, respectively. The annealed HCSs exhibited a good ammonia sensitivity to NH3 concentration (74-295 ppm) over a broad range of relative humidity (10-97%); indeed the values measured were higher than those reported for other nanomaterial based sensors. This study demonstrates the critical role played by humidity and surface chemistry in the ammonia sensing properties of hollow carbon spheres.
doi_str_mv 10.1039/c6ta09424d
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1884110553</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1872833321</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-e4957d2dc7296000c71e1f3c8ffaa692c9fb45903e3de1ed8482d4c988af60bc3</originalsourceid><addsrcrecordid>eNqNkE9LxDAQxYMouKx78RPkKELd_GuaHJdVd4UFL-u5pMmUraRNTbpKv73VFU8enMsMvN88Hg-ha0ruKOF6aeVgiBZMuDM0YyQnWSG0PP-9lbpEi5ReyTSKEKn1DFXb4H34wNbEKnQ49QeIkLDpHDb48Ie27IMf35tu9P0YY_CNCx1gG9o-pGYAbKbntg1dY3CCLoWYrtBFbXyCxc-eo5fHh_16m-2eN0_r1S6zvCBDBkLnhWPOFkzLKaEtKNCaW1XXxkjNrK4rkWvCgTug4JRQzAmrlTK1JJXlc3Rz8u1jeDtCGsq2SRa8Nx2EYyqpUoJSkuf8H2jBFOec0Qm9PaE2hpQi1GUfm9bEsaSk_Kq9XMv96rv2e_4JyLJ2yg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1872833321</pqid></control><display><type>article</type><title>Hollow carbon spheres and a hollow carbon sphere/polyvinylpyrrolidone composite as ammonia sensors</title><source>Royal Society Of Chemistry Journals</source><creator>Mutuma, Bridget K ; Rodrigues, Rafael ; Ranganathan, Kamalakannan ; Matsoso, Boitumelo ; Wamwangi, Daniel ; Huemmelgen, Ivo A ; Coville, Neil J</creator><creatorcontrib>Mutuma, Bridget K ; Rodrigues, Rafael ; Ranganathan, Kamalakannan ; Matsoso, Boitumelo ; Wamwangi, Daniel ; Huemmelgen, Ivo A ; Coville, Neil J</creatorcontrib><description>This study reports on the ammonia vapour sensing behaviour of hollow carbon spheres (HCSs), a hollow carbon sphere-polyvinylpyrrolidone (HCS/PVP) composite and annealed hollow carbon spheres (in a humid environment). For device fabrication, a surfactant assisted method was used to homogeneously disperse the hollow carbon spheres onto an interdigitated electrode. Conductance measurements (sensor response and recovery time) were performed at 20 degree C and 40 degree C. The sensor response was investigated by varying both ammonia concentration and relative humidity. The presence of amorphous domains and oxygenated groups on the pristine hollow carbon spheres resulted in a high relative humidity response. However, the detection of ammonia at high relative humidity using the pristine hollow carbon spheres was found to be negligible due to the inhibition of ammonia adsorption sites by the high concentration of water molecules. In contrast, a decline in conductivity at high relative humidity was recorded in the HCS/PVP sensors due to polymer swelling and plasticization. Annealing of the hollow carbon spheres resulted in a decrease in the amorphous domains in the carbon structure and a subsequent increase in the surface area. The topology of the response was determined as a function of these two variables (NH3 and H2O concentration) and analysed by applying a generalized tristimulus analysis to allow the ammonia concentration to be determined independently of the relative humidity. The pristine HCS, HCS/PVP and annealed HCS sensor responses to 74 ppm NH3 at ambient humidity were 6%, 86% and 196%, respectively. The ammonia sensitivity values (% per ppm) of the pristine HCSs, HCS/PVP and annealed HCSs were 0.08, 4 and 1.6, respectively. The annealed HCSs exhibited a good ammonia sensitivity to NH3 concentration (74-295 ppm) over a broad range of relative humidity (10-97%); indeed the values measured were higher than those reported for other nanomaterial based sensors. This study demonstrates the critical role played by humidity and surface chemistry in the ammonia sensing properties of hollow carbon spheres.</description><identifier>ISSN: 2050-7488</identifier><identifier>EISSN: 2050-7496</identifier><identifier>DOI: 10.1039/c6ta09424d</identifier><language>eng</language><subject>Ammonia ; Annealing ; Carbon ; Detection ; Relative humidity ; Sensitivity ; Sensors ; Surface chemistry</subject><ispartof>Journal of materials chemistry. A, Materials for energy and sustainability, 2017, Vol.5 (6), p.2539-2549</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-e4957d2dc7296000c71e1f3c8ffaa692c9fb45903e3de1ed8482d4c988af60bc3</citedby><cites>FETCH-LOGICAL-c370t-e4957d2dc7296000c71e1f3c8ffaa692c9fb45903e3de1ed8482d4c988af60bc3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Mutuma, Bridget K</creatorcontrib><creatorcontrib>Rodrigues, Rafael</creatorcontrib><creatorcontrib>Ranganathan, Kamalakannan</creatorcontrib><creatorcontrib>Matsoso, Boitumelo</creatorcontrib><creatorcontrib>Wamwangi, Daniel</creatorcontrib><creatorcontrib>Huemmelgen, Ivo A</creatorcontrib><creatorcontrib>Coville, Neil J</creatorcontrib><title>Hollow carbon spheres and a hollow carbon sphere/polyvinylpyrrolidone composite as ammonia sensors</title><title>Journal of materials chemistry. A, Materials for energy and sustainability</title><description>This study reports on the ammonia vapour sensing behaviour of hollow carbon spheres (HCSs), a hollow carbon sphere-polyvinylpyrrolidone (HCS/PVP) composite and annealed hollow carbon spheres (in a humid environment). For device fabrication, a surfactant assisted method was used to homogeneously disperse the hollow carbon spheres onto an interdigitated electrode. Conductance measurements (sensor response and recovery time) were performed at 20 degree C and 40 degree C. The sensor response was investigated by varying both ammonia concentration and relative humidity. The presence of amorphous domains and oxygenated groups on the pristine hollow carbon spheres resulted in a high relative humidity response. However, the detection of ammonia at high relative humidity using the pristine hollow carbon spheres was found to be negligible due to the inhibition of ammonia adsorption sites by the high concentration of water molecules. In contrast, a decline in conductivity at high relative humidity was recorded in the HCS/PVP sensors due to polymer swelling and plasticization. Annealing of the hollow carbon spheres resulted in a decrease in the amorphous domains in the carbon structure and a subsequent increase in the surface area. The topology of the response was determined as a function of these two variables (NH3 and H2O concentration) and analysed by applying a generalized tristimulus analysis to allow the ammonia concentration to be determined independently of the relative humidity. The pristine HCS, HCS/PVP and annealed HCS sensor responses to 74 ppm NH3 at ambient humidity were 6%, 86% and 196%, respectively. The ammonia sensitivity values (% per ppm) of the pristine HCSs, HCS/PVP and annealed HCSs were 0.08, 4 and 1.6, respectively. The annealed HCSs exhibited a good ammonia sensitivity to NH3 concentration (74-295 ppm) over a broad range of relative humidity (10-97%); indeed the values measured were higher than those reported for other nanomaterial based sensors. This study demonstrates the critical role played by humidity and surface chemistry in the ammonia sensing properties of hollow carbon spheres.</description><subject>Ammonia</subject><subject>Annealing</subject><subject>Carbon</subject><subject>Detection</subject><subject>Relative humidity</subject><subject>Sensitivity</subject><subject>Sensors</subject><subject>Surface chemistry</subject><issn>2050-7488</issn><issn>2050-7496</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNkE9LxDAQxYMouKx78RPkKELd_GuaHJdVd4UFL-u5pMmUraRNTbpKv73VFU8enMsMvN88Hg-ha0ruKOF6aeVgiBZMuDM0YyQnWSG0PP-9lbpEi5ReyTSKEKn1DFXb4H34wNbEKnQ49QeIkLDpHDb48Ie27IMf35tu9P0YY_CNCx1gG9o-pGYAbKbntg1dY3CCLoWYrtBFbXyCxc-eo5fHh_16m-2eN0_r1S6zvCBDBkLnhWPOFkzLKaEtKNCaW1XXxkjNrK4rkWvCgTug4JRQzAmrlTK1JJXlc3Rz8u1jeDtCGsq2SRa8Nx2EYyqpUoJSkuf8H2jBFOec0Qm9PaE2hpQi1GUfm9bEsaSk_Kq9XMv96rv2e_4JyLJ2yg</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Mutuma, Bridget K</creator><creator>Rodrigues, Rafael</creator><creator>Ranganathan, Kamalakannan</creator><creator>Matsoso, Boitumelo</creator><creator>Wamwangi, Daniel</creator><creator>Huemmelgen, Ivo A</creator><creator>Coville, Neil J</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7SP</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>2017</creationdate><title>Hollow carbon spheres and a hollow carbon sphere/polyvinylpyrrolidone composite as ammonia sensors</title><author>Mutuma, Bridget K ; Rodrigues, Rafael ; Ranganathan, Kamalakannan ; Matsoso, Boitumelo ; Wamwangi, Daniel ; Huemmelgen, Ivo A ; Coville, Neil J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-e4957d2dc7296000c71e1f3c8ffaa692c9fb45903e3de1ed8482d4c988af60bc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Ammonia</topic><topic>Annealing</topic><topic>Carbon</topic><topic>Detection</topic><topic>Relative humidity</topic><topic>Sensitivity</topic><topic>Sensors</topic><topic>Surface chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mutuma, Bridget K</creatorcontrib><creatorcontrib>Rodrigues, Rafael</creatorcontrib><creatorcontrib>Ranganathan, Kamalakannan</creatorcontrib><creatorcontrib>Matsoso, Boitumelo</creatorcontrib><creatorcontrib>Wamwangi, Daniel</creatorcontrib><creatorcontrib>Huemmelgen, Ivo A</creatorcontrib><creatorcontrib>Coville, Neil J</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of materials chemistry. A, Materials for energy and sustainability</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mutuma, Bridget K</au><au>Rodrigues, Rafael</au><au>Ranganathan, Kamalakannan</au><au>Matsoso, Boitumelo</au><au>Wamwangi, Daniel</au><au>Huemmelgen, Ivo A</au><au>Coville, Neil J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hollow carbon spheres and a hollow carbon sphere/polyvinylpyrrolidone composite as ammonia sensors</atitle><jtitle>Journal of materials chemistry. A, Materials for energy and sustainability</jtitle><date>2017</date><risdate>2017</risdate><volume>5</volume><issue>6</issue><spage>2539</spage><epage>2549</epage><pages>2539-2549</pages><issn>2050-7488</issn><eissn>2050-7496</eissn><abstract>This study reports on the ammonia vapour sensing behaviour of hollow carbon spheres (HCSs), a hollow carbon sphere-polyvinylpyrrolidone (HCS/PVP) composite and annealed hollow carbon spheres (in a humid environment). For device fabrication, a surfactant assisted method was used to homogeneously disperse the hollow carbon spheres onto an interdigitated electrode. Conductance measurements (sensor response and recovery time) were performed at 20 degree C and 40 degree C. The sensor response was investigated by varying both ammonia concentration and relative humidity. The presence of amorphous domains and oxygenated groups on the pristine hollow carbon spheres resulted in a high relative humidity response. However, the detection of ammonia at high relative humidity using the pristine hollow carbon spheres was found to be negligible due to the inhibition of ammonia adsorption sites by the high concentration of water molecules. In contrast, a decline in conductivity at high relative humidity was recorded in the HCS/PVP sensors due to polymer swelling and plasticization. Annealing of the hollow carbon spheres resulted in a decrease in the amorphous domains in the carbon structure and a subsequent increase in the surface area. The topology of the response was determined as a function of these two variables (NH3 and H2O concentration) and analysed by applying a generalized tristimulus analysis to allow the ammonia concentration to be determined independently of the relative humidity. The pristine HCS, HCS/PVP and annealed HCS sensor responses to 74 ppm NH3 at ambient humidity were 6%, 86% and 196%, respectively. The ammonia sensitivity values (% per ppm) of the pristine HCSs, HCS/PVP and annealed HCSs were 0.08, 4 and 1.6, respectively. The annealed HCSs exhibited a good ammonia sensitivity to NH3 concentration (74-295 ppm) over a broad range of relative humidity (10-97%); indeed the values measured were higher than those reported for other nanomaterial based sensors. This study demonstrates the critical role played by humidity and surface chemistry in the ammonia sensing properties of hollow carbon spheres.</abstract><doi>10.1039/c6ta09424d</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2050-7488
ispartof Journal of materials chemistry. A, Materials for energy and sustainability, 2017, Vol.5 (6), p.2539-2549
issn 2050-7488
2050-7496
language eng
recordid cdi_proquest_miscellaneous_1884110553
source Royal Society Of Chemistry Journals
subjects Ammonia
Annealing
Carbon
Detection
Relative humidity
Sensitivity
Sensors
Surface chemistry
title Hollow carbon spheres and a hollow carbon sphere/polyvinylpyrrolidone composite as ammonia sensors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T21%3A34%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hollow%20carbon%20spheres%20and%20a%20hollow%20carbon%20sphere/polyvinylpyrrolidone%20composite%20as%20ammonia%20sensors&rft.jtitle=Journal%20of%20materials%20chemistry.%20A,%20Materials%20for%20energy%20and%20sustainability&rft.au=Mutuma,%20Bridget%20K&rft.date=2017&rft.volume=5&rft.issue=6&rft.spage=2539&rft.epage=2549&rft.pages=2539-2549&rft.issn=2050-7488&rft.eissn=2050-7496&rft_id=info:doi/10.1039/c6ta09424d&rft_dat=%3Cproquest_cross%3E1872833321%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1872833321&rft_id=info:pmid/&rfr_iscdi=true