Breast fat volume measurement using wide-bore 3 T MRI: comparison of traditional mammographic density evaluation with MRI density measurements using automatic segmentation
Aim To compare magnetic resonance imaging (MRI)-derived breast density measurements using automatic segmentation algorithms with radiologist estimations using the Breast Imaging Reporting and Data Systems (BI-RADS) density classification. Materials and methods Forty women undergoing mammography and...
Gespeichert in:
Veröffentlicht in: | Clinical radiology 2017-07, Vol.72 (7), p.565-572 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Aim To compare magnetic resonance imaging (MRI)-derived breast density measurements using automatic segmentation algorithms with radiologist estimations using the Breast Imaging Reporting and Data Systems (BI-RADS) density classification. Materials and methods Forty women undergoing mammography and dynamic breast MRI as part of their clinical management were recruited. Fat–water separated MRI images derived from a two-point Dixon technique, phase-sensitive reconstruction, and atlas-based segmentation were obtained before and after intravenous contrast medium administration. Breast density was assessed using software from Advanced MR Analytics (AMRA), Linköping, Sweden, with results compared to the widely used four-quartile quantitative BI-RADS scale. Results The proportion of glandular tissue in the breast on MRI was derived from the AMRA sequence. The mean unenhanced breast density was 0.31±0.22 (mean±SD; left) and 0.29±0.21 (right). Mean breast density on post-contrast images was 0.32±0.19 (left) and 0.32±0.2 (right). There was “almost perfect” correlation between pre- and post-contrast breast density quantification: Spearman's correlation rho=0.98 (95% confidence intervals [CI]: 0.97–0.99; left) and rho=0.99 (95% CI: 0.98–0.99; right). The 95% limits of agreement were −0.11–0.08 (left) and −0.08–0.03 (right). Interobserver reliability for BI-RADS was “substantial”: weighted Kappa k=0.8 (95% CI: 0.74–0.87). The Spearman correlation coefficient between BI-RADS and MRI breast density was rho=0.73 (95% CI: 0.60–0.82; left) and rho=0.75 (95% CI: 0.63–0.83; right) which was also “substantial”. Conclusion The AMRA sequence provides a fully automated, reproducible, objective assessment of fibroglandular breast tissue proportion that correlates well with mammographic assessment of breast density with the added advantage of avoidance of ionising radiation. |
---|---|
ISSN: | 0009-9260 1365-229X |
DOI: | 10.1016/j.crad.2017.02.014 |