An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations
Occupant centric performance approaches in daylighting studies promote design decisions that support human visual comfort, productivity, and visual preferences, along with more conventional energy efficiency criteria. Simulating per-pixel luminance values and luminance distribution patterns for the...
Gespeichert in:
Veröffentlicht in: | Building and environment 2017-02, Vol.113, p.220-231 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 231 |
---|---|
container_issue | |
container_start_page | 220 |
container_title | Building and environment |
container_volume | 113 |
creator | Inanici, Mehlika Hashemloo, Alireza |
description | Occupant centric performance approaches in daylighting studies promote design decisions that support human visual comfort, productivity, and visual preferences, along with more conventional energy efficiency criteria. Simulating per-pixel luminance values and luminance distribution patterns for the entire scene allows us to analyze the occupant centric metrics and performance criteria. However, there are a number of different sky models, complex fenestration models, and simulation techniques that produce either conventional point in time images or annual luminance maps. This paper discusses the similarities and differences between different techniques; and a comparison analyses provides insight about their impact on occupant centric lighting measures. The comparisons for sky modeling include the conventional CIE skies (Clear, Intermediate, and Overcast), measurement based CIE models, Perez all-weather skies, and high dynamic range image based skies. The comparison of simulation techniques include point in time simulations, image based lighting simulations, and annual luminance simulations (three-phase and five-phase methods). Results demonstrate that measurement based sky models match real world conditions with reasonable proximity, and generic CIE skies consistently underestimate the indoor lighting conditions. Annual simulation methods provide a large database of temporal luminance variations, where individual instances are comparable to point in time simulations. Long term luminance simulations provide opportunities to evaluate the percentage of the year that a given luminance based criteria is met or violated.
•Different sky modeling techniques are compared for their ability to model daylight availability.•Different simulation techniques for point in time and annual simulations are compared for accuracy and consistency.•Findings allow users to select the appropriate sky models and simulations techniques for a given task.•A new annual luminance metric is developed to study the temporal variations in a given space. |
doi_str_mv | 10.1016/j.buildenv.2016.09.022 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1879987363</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0360132316303626</els_id><sourcerecordid>1859496357</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-c7a3851a6f06432ec459d8be270da279f189a7e131de12b5e89070cd53cc85643</originalsourceid><addsrcrecordid>eNqNkU9rGzEQxUVJoY7br1B0zGW30mr_6VZjmqRgyCWF3oQ8mrXlriVX0i7421euk3NyGob5vcfMPEK-clZyxttvh3I72dGgm8sq9yWTJauqD2TB-04UbV__viELJlpWcFGJT-Q2xgPLoBT1gkwrR62bMSa708l6R_1A0x6p0efR7vbJuh2N9jiN12lC2Dv7d8JItTM0_jnTozc4XrBT0JAs5NHgA_UA00m7RAFdChYoznqc_rvEz-TjoMeIX17qkvy6__G8fiw2Tw8_16tNAaLrUwGdFn3DdTuwthYVQt1I02-x6pjRVScH3kvdIRfcIK-2DfaSdQxMIwD6JkuW5O7qewr-snNSRxsBx1E79FNU-UNS5i-14h1oI2vZiqbLaHtFIfgYAw7qFOxRh7PiTF0iUQf1Gom6RKKYVDmSLPx-FWK-ebYYVASLDtDYgJCU8fYti3_EGJsL</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1859496357</pqid></control><display><type>article</type><title>An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations</title><source>Elsevier ScienceDirect Journals</source><creator>Inanici, Mehlika ; Hashemloo, Alireza</creator><creatorcontrib>Inanici, Mehlika ; Hashemloo, Alireza</creatorcontrib><description>Occupant centric performance approaches in daylighting studies promote design decisions that support human visual comfort, productivity, and visual preferences, along with more conventional energy efficiency criteria. Simulating per-pixel luminance values and luminance distribution patterns for the entire scene allows us to analyze the occupant centric metrics and performance criteria. However, there are a number of different sky models, complex fenestration models, and simulation techniques that produce either conventional point in time images or annual luminance maps. This paper discusses the similarities and differences between different techniques; and a comparison analyses provides insight about their impact on occupant centric lighting measures. The comparisons for sky modeling include the conventional CIE skies (Clear, Intermediate, and Overcast), measurement based CIE models, Perez all-weather skies, and high dynamic range image based skies. The comparison of simulation techniques include point in time simulations, image based lighting simulations, and annual luminance simulations (three-phase and five-phase methods). Results demonstrate that measurement based sky models match real world conditions with reasonable proximity, and generic CIE skies consistently underestimate the indoor lighting conditions. Annual simulation methods provide a large database of temporal luminance variations, where individual instances are comparable to point in time simulations. Long term luminance simulations provide opportunities to evaluate the percentage of the year that a given luminance based criteria is met or violated.
•Different sky modeling techniques are compared for their ability to model daylight availability.•Different simulation techniques for point in time and annual simulations are compared for accuracy and consistency.•Findings allow users to select the appropriate sky models and simulations techniques for a given task.•A new annual luminance metric is developed to study the temporal variations in a given space.</description><identifier>ISSN: 0360-1323</identifier><identifier>EISSN: 1873-684X</identifier><identifier>DOI: 10.1016/j.buildenv.2016.09.022</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Annual lighting simulations ; Annual luminance maps ; Computer simulation ; Criteria ; Daylight simulations ; Illumination ; Image based lighting ; Lighting ; Luminance ; Modelling ; Point in time simulations ; Sky models</subject><ispartof>Building and environment, 2017-02, Vol.113, p.220-231</ispartof><rights>2016 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-c7a3851a6f06432ec459d8be270da279f189a7e131de12b5e89070cd53cc85643</citedby><cites>FETCH-LOGICAL-c378t-c7a3851a6f06432ec459d8be270da279f189a7e131de12b5e89070cd53cc85643</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0360132316303626$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Inanici, Mehlika</creatorcontrib><creatorcontrib>Hashemloo, Alireza</creatorcontrib><title>An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations</title><title>Building and environment</title><description>Occupant centric performance approaches in daylighting studies promote design decisions that support human visual comfort, productivity, and visual preferences, along with more conventional energy efficiency criteria. Simulating per-pixel luminance values and luminance distribution patterns for the entire scene allows us to analyze the occupant centric metrics and performance criteria. However, there are a number of different sky models, complex fenestration models, and simulation techniques that produce either conventional point in time images or annual luminance maps. This paper discusses the similarities and differences between different techniques; and a comparison analyses provides insight about their impact on occupant centric lighting measures. The comparisons for sky modeling include the conventional CIE skies (Clear, Intermediate, and Overcast), measurement based CIE models, Perez all-weather skies, and high dynamic range image based skies. The comparison of simulation techniques include point in time simulations, image based lighting simulations, and annual luminance simulations (three-phase and five-phase methods). Results demonstrate that measurement based sky models match real world conditions with reasonable proximity, and generic CIE skies consistently underestimate the indoor lighting conditions. Annual simulation methods provide a large database of temporal luminance variations, where individual instances are comparable to point in time simulations. Long term luminance simulations provide opportunities to evaluate the percentage of the year that a given luminance based criteria is met or violated.
•Different sky modeling techniques are compared for their ability to model daylight availability.•Different simulation techniques for point in time and annual simulations are compared for accuracy and consistency.•Findings allow users to select the appropriate sky models and simulations techniques for a given task.•A new annual luminance metric is developed to study the temporal variations in a given space.</description><subject>Annual lighting simulations</subject><subject>Annual luminance maps</subject><subject>Computer simulation</subject><subject>Criteria</subject><subject>Daylight simulations</subject><subject>Illumination</subject><subject>Image based lighting</subject><subject>Lighting</subject><subject>Luminance</subject><subject>Modelling</subject><subject>Point in time simulations</subject><subject>Sky models</subject><issn>0360-1323</issn><issn>1873-684X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNkU9rGzEQxUVJoY7br1B0zGW30mr_6VZjmqRgyCWF3oQ8mrXlriVX0i7421euk3NyGob5vcfMPEK-clZyxttvh3I72dGgm8sq9yWTJauqD2TB-04UbV__viELJlpWcFGJT-Q2xgPLoBT1gkwrR62bMSa708l6R_1A0x6p0efR7vbJuh2N9jiN12lC2Dv7d8JItTM0_jnTozc4XrBT0JAs5NHgA_UA00m7RAFdChYoznqc_rvEz-TjoMeIX17qkvy6__G8fiw2Tw8_16tNAaLrUwGdFn3DdTuwthYVQt1I02-x6pjRVScH3kvdIRfcIK-2DfaSdQxMIwD6JkuW5O7qewr-snNSRxsBx1E79FNU-UNS5i-14h1oI2vZiqbLaHtFIfgYAw7qFOxRh7PiTF0iUQf1Gom6RKKYVDmSLPx-FWK-ebYYVASLDtDYgJCU8fYti3_EGJsL</recordid><startdate>20170215</startdate><enddate>20170215</enddate><creator>Inanici, Mehlika</creator><creator>Hashemloo, Alireza</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20170215</creationdate><title>An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations</title><author>Inanici, Mehlika ; Hashemloo, Alireza</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-c7a3851a6f06432ec459d8be270da279f189a7e131de12b5e89070cd53cc85643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Annual lighting simulations</topic><topic>Annual luminance maps</topic><topic>Computer simulation</topic><topic>Criteria</topic><topic>Daylight simulations</topic><topic>Illumination</topic><topic>Image based lighting</topic><topic>Lighting</topic><topic>Luminance</topic><topic>Modelling</topic><topic>Point in time simulations</topic><topic>Sky models</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Inanici, Mehlika</creatorcontrib><creatorcontrib>Hashemloo, Alireza</creatorcontrib><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Building and environment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Inanici, Mehlika</au><au>Hashemloo, Alireza</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations</atitle><jtitle>Building and environment</jtitle><date>2017-02-15</date><risdate>2017</risdate><volume>113</volume><spage>220</spage><epage>231</epage><pages>220-231</pages><issn>0360-1323</issn><eissn>1873-684X</eissn><abstract>Occupant centric performance approaches in daylighting studies promote design decisions that support human visual comfort, productivity, and visual preferences, along with more conventional energy efficiency criteria. Simulating per-pixel luminance values and luminance distribution patterns for the entire scene allows us to analyze the occupant centric metrics and performance criteria. However, there are a number of different sky models, complex fenestration models, and simulation techniques that produce either conventional point in time images or annual luminance maps. This paper discusses the similarities and differences between different techniques; and a comparison analyses provides insight about their impact on occupant centric lighting measures. The comparisons for sky modeling include the conventional CIE skies (Clear, Intermediate, and Overcast), measurement based CIE models, Perez all-weather skies, and high dynamic range image based skies. The comparison of simulation techniques include point in time simulations, image based lighting simulations, and annual luminance simulations (three-phase and five-phase methods). Results demonstrate that measurement based sky models match real world conditions with reasonable proximity, and generic CIE skies consistently underestimate the indoor lighting conditions. Annual simulation methods provide a large database of temporal luminance variations, where individual instances are comparable to point in time simulations. Long term luminance simulations provide opportunities to evaluate the percentage of the year that a given luminance based criteria is met or violated.
•Different sky modeling techniques are compared for their ability to model daylight availability.•Different simulation techniques for point in time and annual simulations are compared for accuracy and consistency.•Findings allow users to select the appropriate sky models and simulations techniques for a given task.•A new annual luminance metric is developed to study the temporal variations in a given space.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.buildenv.2016.09.022</doi><tpages>12</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0360-1323 |
ispartof | Building and environment, 2017-02, Vol.113, p.220-231 |
issn | 0360-1323 1873-684X |
language | eng |
recordid | cdi_proquest_miscellaneous_1879987363 |
source | Elsevier ScienceDirect Journals |
subjects | Annual lighting simulations Annual luminance maps Computer simulation Criteria Daylight simulations Illumination Image based lighting Lighting Luminance Modelling Point in time simulations Sky models |
title | An investigation of the daylighting simulation techniques and sky modeling practices for occupant centric evaluations |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T17%3A05%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20investigation%20of%20the%20daylighting%20simulation%20techniques%20and%20sky%20modeling%20practices%20for%20occupant%20centric%20evaluations&rft.jtitle=Building%20and%20environment&rft.au=Inanici,%20Mehlika&rft.date=2017-02-15&rft.volume=113&rft.spage=220&rft.epage=231&rft.pages=220-231&rft.issn=0360-1323&rft.eissn=1873-684X&rft_id=info:doi/10.1016/j.buildenv.2016.09.022&rft_dat=%3Cproquest_cross%3E1859496357%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1859496357&rft_id=info:pmid/&rft_els_id=S0360132316303626&rfr_iscdi=true |