Trends in use of the only Food and Drug Administration-approved commercially available fenestrated endovascular aneurysm repair device in the United States
Abstract Background Fenestrated endografts are customized, patient-specific, endovascular devices with potential to significantly reduce morbidity and mortality of short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair. The Zenith fenestrated endovascular graft (ZFEN) for abdominal ao...
Gespeichert in:
Veröffentlicht in: | Journal of vascular surgery 2017-05, Vol.65 (5), p.1260-1269 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Background Fenestrated endografts are customized, patient-specific, endovascular devices with potential to significantly reduce morbidity and mortality of short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair. The Zenith fenestrated endovascular graft (ZFEN) for abdominal aortic aneurysms (Cook Medical, Bloomington, Ind), Food and Drug Administration-approved in 2012, remains the only fenestrated device available in the United States. This technology is among the most technically complex catheter-based procedures and, therefore, inherently associated with serious risk for device-related complications. We sought to define patterns of physician and hospital adoption of ZFEN. Methods Deidentified datasets containing numbers of physicians trained, orders by physicians and hospitals, and designs (fenestration/scallop configuration) was provided for U.S. ZFEN devices ordered (April 2012-August 2015). We evaluated the number of physicians trained, the number of devices ordered, hospital characteristics, and fenestration/scallop design configurations. Cook Medical assembled the datasets but played no role in study design, analysis, or interpretation of data. Results Between April 2012 and August 2015, 553 physicians attended formal ZFEN training sessions, 388 (70%) of whom ordered a total of 2669 devices. An increase in orders per month (nine in June 2012 and 91 in August 2015, 911% growth; P < .001) and in number of physicians ordering per month (eight in June 2012 and 62 in August 2015, 675% growth; P 20 devices. For physicians contributing >6 months of data (n = 336), the average number of devices ordered per year was three (standard deviation, 4); 272 (81%) ordered ≤ 5 devices/year, 15 (4.5%) ordered 11-20 devices/year, and 3 (0.9%) ordered >20 devices/year. Of devices with design details available (2618 of 2669; 98%), most common designs were 2 small fenestrations/1 scallop (1443, 55%), 2 small fenestrations/1 large fenestration (568, 22%), 1 small fenestration/1 scallop (173, 6.6%), and 2 small fenestrations (169; 6.5%). The average number of target vessels incorpora |
---|---|
ISSN: | 0741-5214 1097-6809 |
DOI: | 10.1016/j.jvs.2016.10.101 |