Application of 2D-HPLC coupled with principal component analysis to study an industrial opiate processing stream

Principal component analysis (PCA) loading plots were used to elucidate key differences between two-dimensional high performance liquid chromatography (2D-HPLC) fingerprint data from samples collected from stages along the Papaver somniferum industrial process chemistry workflow. Data reduction was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2017-05, Vol.166, p.119-125
Hauptverfasser: Stevenson, Paul G., Burns, Niki K., Purcell, Stuart D., Francis, Paul S., Barnett, Neil W., Fry, Fiona, Conlan, Xavier A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 125
container_issue
container_start_page 119
container_title Talanta (Oxford)
container_volume 166
creator Stevenson, Paul G.
Burns, Niki K.
Purcell, Stuart D.
Francis, Paul S.
Barnett, Neil W.
Fry, Fiona
Conlan, Xavier A.
description Principal component analysis (PCA) loading plots were used to elucidate key differences between two-dimensional high performance liquid chromatography (2D-HPLC) fingerprint data from samples collected from stages along the Papaver somniferum industrial process chemistry workflow. Data reduction was completed using a 2D-HPLC peak picking approach as a precursor to chemometric analysis. Using comparisons of the final stages of product extraction as an example, PCA analysis of characteristic 2D-HPLC fingerprints accounted for 84.9% of variation between the two sample sets measured in triplicate, with 64.7% explained by PC1. Loadings plots of PC1 on each sample set identified where the significant changes were occurring and normalised bubble plots provided an indication of the relative importance of each of these changes. These findings highlight 2D-HPLC with appropriate chemometric analysis as a useful tool for the exploration of bioactive molecules within biomass. [Display omitted] •First application of PCA identifying key features in 2D-HPLC data.•Detailed chemical information on opiate processing streams.•Simplified PCA data visualisation with the aid of bubble overlays.
doi_str_mv 10.1016/j.talanta.2017.01.044
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1869966468</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914017301443</els_id><sourcerecordid>1869966468</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-fde675677c2b30eee9bde00b706f06c18fcaab2039d2b5c759d3f9766b9fdeda3</originalsourceid><addsrcrecordid>eNqFkMFu1DAQhq0K1C6FRwD5yCXp2N7YyQlVS0uRVoJDe7YcewJeJXaInaJ9e1ztwpWTpdH3z_j_CHnPoGbA5M2hzmY0IZuaA1M1sBq22wuyYa0SlWiUeEU2AKKrOraFK_ImpQMAcAHiklzxljPBGduQ-XaeR29N9jHQOFD-uXr4vt9RG9d5REd_-_yTzosP1s9mLONpjgFDpiaY8Zh8ojnSlFd3LBPqg1tTXnwh4-xNxhKNFlPy4UehFjTTW_J6MGPCd-f3mjzd3z3uHqr9ty9fd7f7ygrZ5GpwKFUjlbK8F4CIXe8QoFcgB5CWtYM1pueloON9Y1XTOTF0Ssq-K1FnxDX5eNpbfvBrxZT15JPFsTjDuCbNWtl1Um5lW9DmhNolprTgoEvhySxHzUC_yNYHfZatX2RrYLrILrkP5xNrP6H7l_prtwCfTgCWos8eF52sx2DR-QVt1i76_5z4A4mXlZE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1869966468</pqid></control><display><type>article</type><title>Application of 2D-HPLC coupled with principal component analysis to study an industrial opiate processing stream</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><source>MEDLINE</source><creator>Stevenson, Paul G. ; Burns, Niki K. ; Purcell, Stuart D. ; Francis, Paul S. ; Barnett, Neil W. ; Fry, Fiona ; Conlan, Xavier A.</creator><creatorcontrib>Stevenson, Paul G. ; Burns, Niki K. ; Purcell, Stuart D. ; Francis, Paul S. ; Barnett, Neil W. ; Fry, Fiona ; Conlan, Xavier A.</creatorcontrib><description>Principal component analysis (PCA) loading plots were used to elucidate key differences between two-dimensional high performance liquid chromatography (2D-HPLC) fingerprint data from samples collected from stages along the Papaver somniferum industrial process chemistry workflow. Data reduction was completed using a 2D-HPLC peak picking approach as a precursor to chemometric analysis. Using comparisons of the final stages of product extraction as an example, PCA analysis of characteristic 2D-HPLC fingerprints accounted for 84.9% of variation between the two sample sets measured in triplicate, with 64.7% explained by PC1. Loadings plots of PC1 on each sample set identified where the significant changes were occurring and normalised bubble plots provided an indication of the relative importance of each of these changes. These findings highlight 2D-HPLC with appropriate chemometric analysis as a useful tool for the exploration of bioactive molecules within biomass. [Display omitted] •First application of PCA identifying key features in 2D-HPLC data.•Detailed chemical information on opiate processing streams.•Simplified PCA data visualisation with the aid of bubble overlays.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2017.01.044</identifier><identifier>PMID: 28213211</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Chromatography, High Pressure Liquid - methods ; Industry ; Opiate Alkaloids - chemistry ; Papaver somniferum ; Principal Component Analysis ; Two-dimensional high performance liquid chromatography</subject><ispartof>Talanta (Oxford), 2017-05, Vol.166, p.119-125</ispartof><rights>2017 Elsevier B.V.</rights><rights>Copyright © 2017 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-fde675677c2b30eee9bde00b706f06c18fcaab2039d2b5c759d3f9766b9fdeda3</citedby><cites>FETCH-LOGICAL-c365t-fde675677c2b30eee9bde00b706f06c18fcaab2039d2b5c759d3f9766b9fdeda3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.talanta.2017.01.044$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3549,27923,27924,45994</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28213211$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Stevenson, Paul G.</creatorcontrib><creatorcontrib>Burns, Niki K.</creatorcontrib><creatorcontrib>Purcell, Stuart D.</creatorcontrib><creatorcontrib>Francis, Paul S.</creatorcontrib><creatorcontrib>Barnett, Neil W.</creatorcontrib><creatorcontrib>Fry, Fiona</creatorcontrib><creatorcontrib>Conlan, Xavier A.</creatorcontrib><title>Application of 2D-HPLC coupled with principal component analysis to study an industrial opiate processing stream</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Principal component analysis (PCA) loading plots were used to elucidate key differences between two-dimensional high performance liquid chromatography (2D-HPLC) fingerprint data from samples collected from stages along the Papaver somniferum industrial process chemistry workflow. Data reduction was completed using a 2D-HPLC peak picking approach as a precursor to chemometric analysis. Using comparisons of the final stages of product extraction as an example, PCA analysis of characteristic 2D-HPLC fingerprints accounted for 84.9% of variation between the two sample sets measured in triplicate, with 64.7% explained by PC1. Loadings plots of PC1 on each sample set identified where the significant changes were occurring and normalised bubble plots provided an indication of the relative importance of each of these changes. These findings highlight 2D-HPLC with appropriate chemometric analysis as a useful tool for the exploration of bioactive molecules within biomass. [Display omitted] •First application of PCA identifying key features in 2D-HPLC data.•Detailed chemical information on opiate processing streams.•Simplified PCA data visualisation with the aid of bubble overlays.</description><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Industry</subject><subject>Opiate Alkaloids - chemistry</subject><subject>Papaver somniferum</subject><subject>Principal Component Analysis</subject><subject>Two-dimensional high performance liquid chromatography</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMFu1DAQhq0K1C6FRwD5yCXp2N7YyQlVS0uRVoJDe7YcewJeJXaInaJ9e1ztwpWTpdH3z_j_CHnPoGbA5M2hzmY0IZuaA1M1sBq22wuyYa0SlWiUeEU2AKKrOraFK_ImpQMAcAHiklzxljPBGduQ-XaeR29N9jHQOFD-uXr4vt9RG9d5REd_-_yTzosP1s9mLONpjgFDpiaY8Zh8ojnSlFd3LBPqg1tTXnwh4-xNxhKNFlPy4UehFjTTW_J6MGPCd-f3mjzd3z3uHqr9ty9fd7f7ygrZ5GpwKFUjlbK8F4CIXe8QoFcgB5CWtYM1pueloON9Y1XTOTF0Ssq-K1FnxDX5eNpbfvBrxZT15JPFsTjDuCbNWtl1Um5lW9DmhNolprTgoEvhySxHzUC_yNYHfZatX2RrYLrILrkP5xNrP6H7l_prtwCfTgCWos8eF52sx2DR-QVt1i76_5z4A4mXlZE</recordid><startdate>20170501</startdate><enddate>20170501</enddate><creator>Stevenson, Paul G.</creator><creator>Burns, Niki K.</creator><creator>Purcell, Stuart D.</creator><creator>Francis, Paul S.</creator><creator>Barnett, Neil W.</creator><creator>Fry, Fiona</creator><creator>Conlan, Xavier A.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170501</creationdate><title>Application of 2D-HPLC coupled with principal component analysis to study an industrial opiate processing stream</title><author>Stevenson, Paul G. ; Burns, Niki K. ; Purcell, Stuart D. ; Francis, Paul S. ; Barnett, Neil W. ; Fry, Fiona ; Conlan, Xavier A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-fde675677c2b30eee9bde00b706f06c18fcaab2039d2b5c759d3f9766b9fdeda3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Industry</topic><topic>Opiate Alkaloids - chemistry</topic><topic>Papaver somniferum</topic><topic>Principal Component Analysis</topic><topic>Two-dimensional high performance liquid chromatography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stevenson, Paul G.</creatorcontrib><creatorcontrib>Burns, Niki K.</creatorcontrib><creatorcontrib>Purcell, Stuart D.</creatorcontrib><creatorcontrib>Francis, Paul S.</creatorcontrib><creatorcontrib>Barnett, Neil W.</creatorcontrib><creatorcontrib>Fry, Fiona</creatorcontrib><creatorcontrib>Conlan, Xavier A.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stevenson, Paul G.</au><au>Burns, Niki K.</au><au>Purcell, Stuart D.</au><au>Francis, Paul S.</au><au>Barnett, Neil W.</au><au>Fry, Fiona</au><au>Conlan, Xavier A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of 2D-HPLC coupled with principal component analysis to study an industrial opiate processing stream</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2017-05-01</date><risdate>2017</risdate><volume>166</volume><spage>119</spage><epage>125</epage><pages>119-125</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>Principal component analysis (PCA) loading plots were used to elucidate key differences between two-dimensional high performance liquid chromatography (2D-HPLC) fingerprint data from samples collected from stages along the Papaver somniferum industrial process chemistry workflow. Data reduction was completed using a 2D-HPLC peak picking approach as a precursor to chemometric analysis. Using comparisons of the final stages of product extraction as an example, PCA analysis of characteristic 2D-HPLC fingerprints accounted for 84.9% of variation between the two sample sets measured in triplicate, with 64.7% explained by PC1. Loadings plots of PC1 on each sample set identified where the significant changes were occurring and normalised bubble plots provided an indication of the relative importance of each of these changes. These findings highlight 2D-HPLC with appropriate chemometric analysis as a useful tool for the exploration of bioactive molecules within biomass. [Display omitted] •First application of PCA identifying key features in 2D-HPLC data.•Detailed chemical information on opiate processing streams.•Simplified PCA data visualisation with the aid of bubble overlays.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>28213211</pmid><doi>10.1016/j.talanta.2017.01.044</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2017-05, Vol.166, p.119-125
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_1869966468
source Elsevier ScienceDirect Journals Complete - AutoHoldings; MEDLINE
subjects Chromatography, High Pressure Liquid - methods
Industry
Opiate Alkaloids - chemistry
Papaver somniferum
Principal Component Analysis
Two-dimensional high performance liquid chromatography
title Application of 2D-HPLC coupled with principal component analysis to study an industrial opiate processing stream
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T06%3A27%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%202D-HPLC%20coupled%20with%20principal%20component%20analysis%20to%20study%20an%20industrial%20opiate%20processing%20stream&rft.jtitle=Talanta%20(Oxford)&rft.au=Stevenson,%20Paul%20G.&rft.date=2017-05-01&rft.volume=166&rft.spage=119&rft.epage=125&rft.pages=119-125&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2017.01.044&rft_dat=%3Cproquest_cross%3E1869966468%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1869966468&rft_id=info:pmid/28213211&rft_els_id=S0039914017301443&rfr_iscdi=true