Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system

The development of an automated kinetic-catalytic spectrophotometric method for cobalt determination is presented. The method is based on the catalytic effect of Co in the oxidation of hydroxybenzoic acid by H2O2 in basic media. The method has been automated using a multisyringe flow injection syste...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2017-05, Vol.166, p.405-411
Hauptverfasser: Abouhiat, Fatima Zohra, Henríquez, Camelia, El Yousfi, Farida, Cerdà, Víctor
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 411
container_issue
container_start_page 405
container_title Talanta (Oxford)
container_volume 166
creator Abouhiat, Fatima Zohra
Henríquez, Camelia
El Yousfi, Farida
Cerdà, Víctor
description The development of an automated kinetic-catalytic spectrophotometric method for cobalt determination is presented. The method is based on the catalytic effect of Co in the oxidation of hydroxybenzoic acid by H2O2 in basic media. The method has been automated using a multisyringe flow injection system coupled to a monolithic flow conduit called chip (chip-MSFIA). All reagents and sample are simultaneously propelled into the chip to achieve an efficient mixing. The reaction product is monitored at 482nm. The reaction takes place very fast at room temperature, thus the fixed-time method is applied to quantify Co concentration in samples. Variables such as, reagents concentration, pH, flow rate and reaction time have been optimized to improve the selectivity and sensitivity of the proposed system. Under optimal conditions, Co may be determined in the range 0.02–10.00μgL−1 achieving a limit of detection of 0.02μgL−1 and an injection throughput of 68h−1. Relative standard deviations are below 3%. The method has been successfully applied to water samples and a pharmaceutical formulation. The accuracy of the method has been validated by add-recovery tests and satisfactory recoveries from 91% to 97% were obtained. A chip-MSFIA system used for the kinetic-catalytic determination of Co(II). [Display omitted] •Coupling MSFIA with a chip results in a fully automated method.•This method is very sensitive reaching lower detection limit than ICP-OES.•Provides a sample throughput higher than other reported flow techniques.•It is able to on-line analyze cobalt in waters and pharmaceutical products.
doi_str_mv 10.1016/j.talanta.2015.12.005
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1869966467</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914015305324</els_id><sourcerecordid>1869966467</sourcerecordid><originalsourceid>FETCH-LOGICAL-c365t-a21d4b18a701e68d6f8748df4ee0622132da7f0889ee717a43ce36ace5ae57de3</originalsourceid><addsrcrecordid>eNqFUc1u1DAQthAV3RYeAeQjlwT_JLZzQqgqUKlSD4Wz5bUnrJfEDrbTat-DB8arXbhymtHM96OZD6G3lLSUUPFh3xYzmVBMywjtW8paQvoXaEOV5A3vJX-JNoTwoRloRy7RVc57QgjjhL9Cl0wxylnPN-j3I4Tsi38C_NMHKN421lTlQ-1wXsCWFJddLHGGkuqoll10eIwJ27g1U8EOCqTZB1N8DHjNPvzABtudXypiXSZwuMQ6mdep-HxIdQ94nOIz9mFf9Y8sE6pj9hnnQy4wv0YXo5kyvDnXa_T98-23m6_N_cOXu5tP943loi-NYdR1W6qMJBSEcmJUslNu7ACIYMcLnZEjUWoAkFSajlvgwljoDfTSAb9G70-6S4q_VshFzz5bmOpfIa5ZUyWGQYhOyArtT1CbYs4JRr0kP5t00JToYyB6r8-B6GMgmjJdA6m8d2eLdTuD-8f6m0AFfDwBoB765CHpbD0EC86n-h3tov-PxR_bDqQe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1869966467</pqid></control><display><type>article</type><title>Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system</title><source>Elsevier ScienceDirect Journals</source><creator>Abouhiat, Fatima Zohra ; Henríquez, Camelia ; El Yousfi, Farida ; Cerdà, Víctor</creator><creatorcontrib>Abouhiat, Fatima Zohra ; Henríquez, Camelia ; El Yousfi, Farida ; Cerdà, Víctor</creatorcontrib><description>The development of an automated kinetic-catalytic spectrophotometric method for cobalt determination is presented. The method is based on the catalytic effect of Co in the oxidation of hydroxybenzoic acid by H2O2 in basic media. The method has been automated using a multisyringe flow injection system coupled to a monolithic flow conduit called chip (chip-MSFIA). All reagents and sample are simultaneously propelled into the chip to achieve an efficient mixing. The reaction product is monitored at 482nm. The reaction takes place very fast at room temperature, thus the fixed-time method is applied to quantify Co concentration in samples. Variables such as, reagents concentration, pH, flow rate and reaction time have been optimized to improve the selectivity and sensitivity of the proposed system. Under optimal conditions, Co may be determined in the range 0.02–10.00μgL−1 achieving a limit of detection of 0.02μgL−1 and an injection throughput of 68h−1. Relative standard deviations are below 3%. The method has been successfully applied to water samples and a pharmaceutical formulation. The accuracy of the method has been validated by add-recovery tests and satisfactory recoveries from 91% to 97% were obtained. A chip-MSFIA system used for the kinetic-catalytic determination of Co(II). [Display omitted] •Coupling MSFIA with a chip results in a fully automated method.•This method is very sensitive reaching lower detection limit than ICP-OES.•Provides a sample throughput higher than other reported flow techniques.•It is able to on-line analyze cobalt in waters and pharmaceutical products.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2015.12.005</identifier><identifier>PMID: 28213253</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Chip-MSFIA ; Kinetic catalytic method ; Pharmaceutical preparation ; Water samples</subject><ispartof>Talanta (Oxford), 2017-05, Vol.166, p.405-411</ispartof><rights>2015 Elsevier B.V.</rights><rights>Copyright © 2015 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c365t-a21d4b18a701e68d6f8748df4ee0622132da7f0889ee717a43ce36ace5ae57de3</citedby><cites>FETCH-LOGICAL-c365t-a21d4b18a701e68d6f8748df4ee0622132da7f0889ee717a43ce36ace5ae57de3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914015305324$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27903,27904,65308</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28213253$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Abouhiat, Fatima Zohra</creatorcontrib><creatorcontrib>Henríquez, Camelia</creatorcontrib><creatorcontrib>El Yousfi, Farida</creatorcontrib><creatorcontrib>Cerdà, Víctor</creatorcontrib><title>Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>The development of an automated kinetic-catalytic spectrophotometric method for cobalt determination is presented. The method is based on the catalytic effect of Co in the oxidation of hydroxybenzoic acid by H2O2 in basic media. The method has been automated using a multisyringe flow injection system coupled to a monolithic flow conduit called chip (chip-MSFIA). All reagents and sample are simultaneously propelled into the chip to achieve an efficient mixing. The reaction product is monitored at 482nm. The reaction takes place very fast at room temperature, thus the fixed-time method is applied to quantify Co concentration in samples. Variables such as, reagents concentration, pH, flow rate and reaction time have been optimized to improve the selectivity and sensitivity of the proposed system. Under optimal conditions, Co may be determined in the range 0.02–10.00μgL−1 achieving a limit of detection of 0.02μgL−1 and an injection throughput of 68h−1. Relative standard deviations are below 3%. The method has been successfully applied to water samples and a pharmaceutical formulation. The accuracy of the method has been validated by add-recovery tests and satisfactory recoveries from 91% to 97% were obtained. A chip-MSFIA system used for the kinetic-catalytic determination of Co(II). [Display omitted] •Coupling MSFIA with a chip results in a fully automated method.•This method is very sensitive reaching lower detection limit than ICP-OES.•Provides a sample throughput higher than other reported flow techniques.•It is able to on-line analyze cobalt in waters and pharmaceutical products.</description><subject>Chip-MSFIA</subject><subject>Kinetic catalytic method</subject><subject>Pharmaceutical preparation</subject><subject>Water samples</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqFUc1u1DAQthAV3RYeAeQjlwT_JLZzQqgqUKlSD4Wz5bUnrJfEDrbTat-DB8arXbhymtHM96OZD6G3lLSUUPFh3xYzmVBMywjtW8paQvoXaEOV5A3vJX-JNoTwoRloRy7RVc57QgjjhL9Cl0wxylnPN-j3I4Tsi38C_NMHKN421lTlQ-1wXsCWFJddLHGGkuqoll10eIwJ27g1U8EOCqTZB1N8DHjNPvzABtudXypiXSZwuMQ6mdep-HxIdQ94nOIz9mFf9Y8sE6pj9hnnQy4wv0YXo5kyvDnXa_T98-23m6_N_cOXu5tP943loi-NYdR1W6qMJBSEcmJUslNu7ACIYMcLnZEjUWoAkFSajlvgwljoDfTSAb9G70-6S4q_VshFzz5bmOpfIa5ZUyWGQYhOyArtT1CbYs4JRr0kP5t00JToYyB6r8-B6GMgmjJdA6m8d2eLdTuD-8f6m0AFfDwBoB765CHpbD0EC86n-h3tov-PxR_bDqQe</recordid><startdate>20170501</startdate><enddate>20170501</enddate><creator>Abouhiat, Fatima Zohra</creator><creator>Henríquez, Camelia</creator><creator>El Yousfi, Farida</creator><creator>Cerdà, Víctor</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170501</creationdate><title>Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system</title><author>Abouhiat, Fatima Zohra ; Henríquez, Camelia ; El Yousfi, Farida ; Cerdà, Víctor</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c365t-a21d4b18a701e68d6f8748df4ee0622132da7f0889ee717a43ce36ace5ae57de3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Chip-MSFIA</topic><topic>Kinetic catalytic method</topic><topic>Pharmaceutical preparation</topic><topic>Water samples</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abouhiat, Fatima Zohra</creatorcontrib><creatorcontrib>Henríquez, Camelia</creatorcontrib><creatorcontrib>El Yousfi, Farida</creatorcontrib><creatorcontrib>Cerdà, Víctor</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abouhiat, Fatima Zohra</au><au>Henríquez, Camelia</au><au>El Yousfi, Farida</au><au>Cerdà, Víctor</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2017-05-01</date><risdate>2017</risdate><volume>166</volume><spage>405</spage><epage>411</epage><pages>405-411</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>The development of an automated kinetic-catalytic spectrophotometric method for cobalt determination is presented. The method is based on the catalytic effect of Co in the oxidation of hydroxybenzoic acid by H2O2 in basic media. The method has been automated using a multisyringe flow injection system coupled to a monolithic flow conduit called chip (chip-MSFIA). All reagents and sample are simultaneously propelled into the chip to achieve an efficient mixing. The reaction product is monitored at 482nm. The reaction takes place very fast at room temperature, thus the fixed-time method is applied to quantify Co concentration in samples. Variables such as, reagents concentration, pH, flow rate and reaction time have been optimized to improve the selectivity and sensitivity of the proposed system. Under optimal conditions, Co may be determined in the range 0.02–10.00μgL−1 achieving a limit of detection of 0.02μgL−1 and an injection throughput of 68h−1. Relative standard deviations are below 3%. The method has been successfully applied to water samples and a pharmaceutical formulation. The accuracy of the method has been validated by add-recovery tests and satisfactory recoveries from 91% to 97% were obtained. A chip-MSFIA system used for the kinetic-catalytic determination of Co(II). [Display omitted] •Coupling MSFIA with a chip results in a fully automated method.•This method is very sensitive reaching lower detection limit than ICP-OES.•Provides a sample throughput higher than other reported flow techniques.•It is able to on-line analyze cobalt in waters and pharmaceutical products.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>28213253</pmid><doi>10.1016/j.talanta.2015.12.005</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2017-05, Vol.166, p.405-411
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_1869966467
source Elsevier ScienceDirect Journals
subjects Chip-MSFIA
Kinetic catalytic method
Pharmaceutical preparation
Water samples
title Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T09%3A42%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sensitive%20kinetic-catalytic%20spectrophotometric%20method%20for%20cobalt%20determination%20using%20a%20chip%20coupled%20to%20a%20multisyringe%20flow%20injection%20analysis%20system&rft.jtitle=Talanta%20(Oxford)&rft.au=Abouhiat,%20Fatima%C2%A0Zohra&rft.date=2017-05-01&rft.volume=166&rft.spage=405&rft.epage=411&rft.pages=405-411&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2015.12.005&rft_dat=%3Cproquest_cross%3E1869966467%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1869966467&rft_id=info:pmid/28213253&rft_els_id=S0039914015305324&rfr_iscdi=true