A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching

A new method for the preparation of freestanding thin film samples for mechanical testing in transmission electron microscopes is presented. It is based on a combination of focused ion beam (FIB) milling and electron-beam-assisted etching with xenon difluoride (XeF2) precursor gas. The use of the FI...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultramicroscopy 2016-12, Vol.171, p.82-88
Hauptverfasser: Liebig, J.P., Göken, M., Richter, G., Mačković, M., Przybilla, T., Spiecker, E., Pierron, O.N., Merle, B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 88
container_issue
container_start_page 82
container_title Ultramicroscopy
container_volume 171
creator Liebig, J.P.
Göken, M.
Richter, G.
Mačković, M.
Przybilla, T.
Spiecker, E.
Pierron, O.N.
Merle, B.
description A new method for the preparation of freestanding thin film samples for mechanical testing in transmission electron microscopes is presented. It is based on a combination of focused ion beam (FIB) milling and electron-beam-assisted etching with xenon difluoride (XeF2) precursor gas. The use of the FIB allows for the target preparation of microstructural defects and enables well-defined sample geometries which can be easily adapted in order to meet the requirements of various testing setups. In contrast to existing FIB-based preparation approaches, the area of interest is never exposed to ion beam irradiation which preserves a pristine microstructure. The method can be applied to a wide range of thin film material systems compatible with XeF2 etching. Its feasibility is demonstrated for gold and alloyed copper thin films and its practical application is discussed. •A new method for the preparation of sub-micron tensile specimens from thin films is presented.•The method is based on the combination of focused ion beam milling and electron-beam-assisted xenon difluoride etching.•It enables the target preparation of individual microstructural defects.•The sample section is protected from ion beam damage by the use of a shadow milling geometry.
doi_str_mv 10.1016/j.ultramic.2016.09.004
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1864535054</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0304399116301942</els_id><sourcerecordid>1864535054</sourcerecordid><originalsourceid>FETCH-LOGICAL-c467t-5e155e015b05262598924034b76364216f94e988eba0da084c3ab54348e2cde93</originalsourceid><addsrcrecordid>eNqFkUtv1DAUhS0EokPhL1Reskmw40fiHaXqSypiU9aW49x0PLLjYHt4_RX-LB6mZdvVlY--c498D0JnlLSUUPlh1-59SSY423b13RLVEsJfoA0detV0fcdeog1hhDdMKXqC3uS8I4RQwofX6KTrJWdc0g36c45nDz_d6AEHKNs44TkmXLaA1wSrSaa4uOA4V8kteHY-4GzC6iH_A6uWXdnj-8vP2G4rbgsk9_vosjGMbnHLA85bM8UfzdXtJxyc9wfJLBMGD7akuDQjmNCYnF0uUOVia9jDW_RqNj7Du8d5ir5eXd5f3DR3X65vL87vGstlXxoBVAggVIxEdLITalAdJ4yPvWSSd1TOioMaBhgNmQwZuGVmFPX_A3R2AsVO0fvj3jXFb3vIRQeXLXhvFoj7rOkguWCCVM_zKFOUsV6IisojalPMOcGs1-SCSb80JfrQod7ppw71oUNNlK4dVuPZY8Z-DDD9tz2VVoGPRwDqUb47SDpbB4uFyaV6Tz1F91zGXxuvshQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1839133755</pqid></control><display><type>article</type><title>A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching</title><source>ScienceDirect Journals (5 years ago - present)</source><creator>Liebig, J.P. ; Göken, M. ; Richter, G. ; Mačković, M. ; Przybilla, T. ; Spiecker, E. ; Pierron, O.N. ; Merle, B.</creator><creatorcontrib>Liebig, J.P. ; Göken, M. ; Richter, G. ; Mačković, M. ; Przybilla, T. ; Spiecker, E. ; Pierron, O.N. ; Merle, B.</creatorcontrib><description>A new method for the preparation of freestanding thin film samples for mechanical testing in transmission electron microscopes is presented. It is based on a combination of focused ion beam (FIB) milling and electron-beam-assisted etching with xenon difluoride (XeF2) precursor gas. The use of the FIB allows for the target preparation of microstructural defects and enables well-defined sample geometries which can be easily adapted in order to meet the requirements of various testing setups. In contrast to existing FIB-based preparation approaches, the area of interest is never exposed to ion beam irradiation which preserves a pristine microstructure. The method can be applied to a wide range of thin film material systems compatible with XeF2 etching. Its feasibility is demonstrated for gold and alloyed copper thin films and its practical application is discussed. •A new method for the preparation of sub-micron tensile specimens from thin films is presented.•The method is based on the combination of focused ion beam milling and electron-beam-assisted xenon difluoride etching.•It enables the target preparation of individual microstructural defects.•The sample section is protected from ion beam damage by the use of a shadow milling geometry.</description><identifier>ISSN: 0304-3991</identifier><identifier>EISSN: 1879-2723</identifier><identifier>DOI: 10.1016/j.ultramic.2016.09.004</identifier><identifier>PMID: 27643461</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Electron microscopes ; Electron-beam-assisted etching ; Etching ; FIB ; Ion beams ; Mechanical testing ; Micromechanical testing ; Microstructure ; Preserves ; Thin films ; Transmission electron microscopy ; XeF2</subject><ispartof>Ultramicroscopy, 2016-12, Vol.171, p.82-88</ispartof><rights>2016 Elsevier B.V.</rights><rights>Copyright © 2016 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c467t-5e155e015b05262598924034b76364216f94e988eba0da084c3ab54348e2cde93</citedby><cites>FETCH-LOGICAL-c467t-5e155e015b05262598924034b76364216f94e988eba0da084c3ab54348e2cde93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ultramic.2016.09.004$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27643461$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Liebig, J.P.</creatorcontrib><creatorcontrib>Göken, M.</creatorcontrib><creatorcontrib>Richter, G.</creatorcontrib><creatorcontrib>Mačković, M.</creatorcontrib><creatorcontrib>Przybilla, T.</creatorcontrib><creatorcontrib>Spiecker, E.</creatorcontrib><creatorcontrib>Pierron, O.N.</creatorcontrib><creatorcontrib>Merle, B.</creatorcontrib><title>A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching</title><title>Ultramicroscopy</title><addtitle>Ultramicroscopy</addtitle><description>A new method for the preparation of freestanding thin film samples for mechanical testing in transmission electron microscopes is presented. It is based on a combination of focused ion beam (FIB) milling and electron-beam-assisted etching with xenon difluoride (XeF2) precursor gas. The use of the FIB allows for the target preparation of microstructural defects and enables well-defined sample geometries which can be easily adapted in order to meet the requirements of various testing setups. In contrast to existing FIB-based preparation approaches, the area of interest is never exposed to ion beam irradiation which preserves a pristine microstructure. The method can be applied to a wide range of thin film material systems compatible with XeF2 etching. Its feasibility is demonstrated for gold and alloyed copper thin films and its practical application is discussed. •A new method for the preparation of sub-micron tensile specimens from thin films is presented.•The method is based on the combination of focused ion beam milling and electron-beam-assisted xenon difluoride etching.•It enables the target preparation of individual microstructural defects.•The sample section is protected from ion beam damage by the use of a shadow milling geometry.</description><subject>Electron microscopes</subject><subject>Electron-beam-assisted etching</subject><subject>Etching</subject><subject>FIB</subject><subject>Ion beams</subject><subject>Mechanical testing</subject><subject>Micromechanical testing</subject><subject>Microstructure</subject><subject>Preserves</subject><subject>Thin films</subject><subject>Transmission electron microscopy</subject><subject>XeF2</subject><issn>0304-3991</issn><issn>1879-2723</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqFkUtv1DAUhS0EokPhL1Reskmw40fiHaXqSypiU9aW49x0PLLjYHt4_RX-LB6mZdvVlY--c498D0JnlLSUUPlh1-59SSY423b13RLVEsJfoA0detV0fcdeog1hhDdMKXqC3uS8I4RQwofX6KTrJWdc0g36c45nDz_d6AEHKNs44TkmXLaA1wSrSaa4uOA4V8kteHY-4GzC6iH_A6uWXdnj-8vP2G4rbgsk9_vosjGMbnHLA85bM8UfzdXtJxyc9wfJLBMGD7akuDQjmNCYnF0uUOVia9jDW_RqNj7Du8d5ir5eXd5f3DR3X65vL87vGstlXxoBVAggVIxEdLITalAdJ4yPvWSSd1TOioMaBhgNmQwZuGVmFPX_A3R2AsVO0fvj3jXFb3vIRQeXLXhvFoj7rOkguWCCVM_zKFOUsV6IisojalPMOcGs1-SCSb80JfrQod7ppw71oUNNlK4dVuPZY8Z-DDD9tz2VVoGPRwDqUb47SDpbB4uFyaV6Tz1F91zGXxuvshQ</recordid><startdate>201612</startdate><enddate>201612</enddate><creator>Liebig, J.P.</creator><creator>Göken, M.</creator><creator>Richter, G.</creator><creator>Mačković, M.</creator><creator>Przybilla, T.</creator><creator>Spiecker, E.</creator><creator>Pierron, O.N.</creator><creator>Merle, B.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>201612</creationdate><title>A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching</title><author>Liebig, J.P. ; Göken, M. ; Richter, G. ; Mačković, M. ; Przybilla, T. ; Spiecker, E. ; Pierron, O.N. ; Merle, B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c467t-5e155e015b05262598924034b76364216f94e988eba0da084c3ab54348e2cde93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Electron microscopes</topic><topic>Electron-beam-assisted etching</topic><topic>Etching</topic><topic>FIB</topic><topic>Ion beams</topic><topic>Mechanical testing</topic><topic>Micromechanical testing</topic><topic>Microstructure</topic><topic>Preserves</topic><topic>Thin films</topic><topic>Transmission electron microscopy</topic><topic>XeF2</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liebig, J.P.</creatorcontrib><creatorcontrib>Göken, M.</creatorcontrib><creatorcontrib>Richter, G.</creatorcontrib><creatorcontrib>Mačković, M.</creatorcontrib><creatorcontrib>Przybilla, T.</creatorcontrib><creatorcontrib>Spiecker, E.</creatorcontrib><creatorcontrib>Pierron, O.N.</creatorcontrib><creatorcontrib>Merle, B.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Ultramicroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Liebig, J.P.</au><au>Göken, M.</au><au>Richter, G.</au><au>Mačković, M.</au><au>Przybilla, T.</au><au>Spiecker, E.</au><au>Pierron, O.N.</au><au>Merle, B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching</atitle><jtitle>Ultramicroscopy</jtitle><addtitle>Ultramicroscopy</addtitle><date>2016-12</date><risdate>2016</risdate><volume>171</volume><spage>82</spage><epage>88</epage><pages>82-88</pages><issn>0304-3991</issn><eissn>1879-2723</eissn><abstract>A new method for the preparation of freestanding thin film samples for mechanical testing in transmission electron microscopes is presented. It is based on a combination of focused ion beam (FIB) milling and electron-beam-assisted etching with xenon difluoride (XeF2) precursor gas. The use of the FIB allows for the target preparation of microstructural defects and enables well-defined sample geometries which can be easily adapted in order to meet the requirements of various testing setups. In contrast to existing FIB-based preparation approaches, the area of interest is never exposed to ion beam irradiation which preserves a pristine microstructure. The method can be applied to a wide range of thin film material systems compatible with XeF2 etching. Its feasibility is demonstrated for gold and alloyed copper thin films and its practical application is discussed. •A new method for the preparation of sub-micron tensile specimens from thin films is presented.•The method is based on the combination of focused ion beam milling and electron-beam-assisted xenon difluoride etching.•It enables the target preparation of individual microstructural defects.•The sample section is protected from ion beam damage by the use of a shadow milling geometry.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>27643461</pmid><doi>10.1016/j.ultramic.2016.09.004</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0304-3991
ispartof Ultramicroscopy, 2016-12, Vol.171, p.82-88
issn 0304-3991
1879-2723
language eng
recordid cdi_proquest_miscellaneous_1864535054
source ScienceDirect Journals (5 years ago - present)
subjects Electron microscopes
Electron-beam-assisted etching
Etching
FIB
Ion beams
Mechanical testing
Micromechanical testing
Microstructure
Preserves
Thin films
Transmission electron microscopy
XeF2
title A flexible method for the preparation of thin film samples for in situ TEM characterization combining shadow-FIB milling and electron-beam-assisted etching
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T21%3A21%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20flexible%20method%20for%20the%20preparation%20of%20thin%20film%20samples%20for%20in%20situ%20TEM%20characterization%20combining%20shadow-FIB%20milling%20and%20electron-beam-assisted%20etching&rft.jtitle=Ultramicroscopy&rft.au=Liebig,%20J.P.&rft.date=2016-12&rft.volume=171&rft.spage=82&rft.epage=88&rft.pages=82-88&rft.issn=0304-3991&rft.eissn=1879-2723&rft_id=info:doi/10.1016/j.ultramic.2016.09.004&rft_dat=%3Cproquest_cross%3E1864535054%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1839133755&rft_id=info:pmid/27643461&rft_els_id=S0304399116301942&rfr_iscdi=true