Pump-probe spectrometer for measuring x-rayinduced strain
A hard x-ray pump-probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. We present a proof-...
Gespeichert in:
Veröffentlicht in: | Optics letters 2016-05, Vol.41 (9), p.1977-1980 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1980 |
---|---|
container_issue | 9 |
container_start_page | 1977 |
container_title | Optics letters |
container_volume | 41 |
creator | Loether, A Adams, B W Dicharia, A Gao, Y Henning, R Walko, D A Decamp, M F |
description | A hard x-ray pump-probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. We present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain. |
doi_str_mv | 10.1364/OL.41.001977 |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1864532104</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1864532104</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_18645321043</originalsourceid><addsrcrecordid>eNqVzL0KwjAUQOEgCtafzQfI6NKaNGlqZlEcBB3cS2xvpdI0NbcBfXsRfAGns3wcQlacJVwouTmfEskTxrjO8xGJeCZ0LHMtxyRiXKpYZzqdkhnigzGmciEioi_B9nHv3Q0o9lAO3lkYwNPaeWrBYPBNd6ev2Jt301WhhIri4E3TLcikNi3C8tc5WR_2193xO3sGwKGwDZbQtqYDF7DgWyUzkXImxR_0A62zQLE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1864532104</pqid></control><display><type>article</type><title>Pump-probe spectrometer for measuring x-rayinduced strain</title><source>Optica Publishing Group Journals</source><creator>Loether, A ; Adams, B W ; Dicharia, A ; Gao, Y ; Henning, R ; Walko, D A ; Decamp, M F</creator><creatorcontrib>Loether, A ; Adams, B W ; Dicharia, A ; Gao, Y ; Henning, R ; Walko, D A ; Decamp, M F</creatorcontrib><description>A hard x-ray pump-probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. We present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.</description><identifier>ISSN: 0146-9592</identifier><identifier>EISSN: 1539-4794</identifier><identifier>DOI: 10.1364/OL.41.001977</identifier><language>eng</language><subject>Bragg reflectors ; Broadband ; Crystal structure ; Pumps ; Spectrometers ; Synchrotrons ; X-ray sources ; X-rays</subject><ispartof>Optics letters, 2016-05, Vol.41 (9), p.1977-1980</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Loether, A</creatorcontrib><creatorcontrib>Adams, B W</creatorcontrib><creatorcontrib>Dicharia, A</creatorcontrib><creatorcontrib>Gao, Y</creatorcontrib><creatorcontrib>Henning, R</creatorcontrib><creatorcontrib>Walko, D A</creatorcontrib><creatorcontrib>Decamp, M F</creatorcontrib><title>Pump-probe spectrometer for measuring x-rayinduced strain</title><title>Optics letters</title><description>A hard x-ray pump-probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. We present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.</description><subject>Bragg reflectors</subject><subject>Broadband</subject><subject>Crystal structure</subject><subject>Pumps</subject><subject>Spectrometers</subject><subject>Synchrotrons</subject><subject>X-ray sources</subject><subject>X-rays</subject><issn>0146-9592</issn><issn>1539-4794</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqVzL0KwjAUQOEgCtafzQfI6NKaNGlqZlEcBB3cS2xvpdI0NbcBfXsRfAGns3wcQlacJVwouTmfEskTxrjO8xGJeCZ0LHMtxyRiXKpYZzqdkhnigzGmciEioi_B9nHv3Q0o9lAO3lkYwNPaeWrBYPBNd6ev2Jt301WhhIri4E3TLcikNi3C8tc5WR_2193xO3sGwKGwDZbQtqYDF7DgWyUzkXImxR_0A62zQLE</recordid><startdate>20160501</startdate><enddate>20160501</enddate><creator>Loether, A</creator><creator>Adams, B W</creator><creator>Dicharia, A</creator><creator>Gao, Y</creator><creator>Henning, R</creator><creator>Walko, D A</creator><creator>Decamp, M F</creator><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20160501</creationdate><title>Pump-probe spectrometer for measuring x-rayinduced strain</title><author>Loether, A ; Adams, B W ; Dicharia, A ; Gao, Y ; Henning, R ; Walko, D A ; Decamp, M F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_18645321043</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Bragg reflectors</topic><topic>Broadband</topic><topic>Crystal structure</topic><topic>Pumps</topic><topic>Spectrometers</topic><topic>Synchrotrons</topic><topic>X-ray sources</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Loether, A</creatorcontrib><creatorcontrib>Adams, B W</creatorcontrib><creatorcontrib>Dicharia, A</creatorcontrib><creatorcontrib>Gao, Y</creatorcontrib><creatorcontrib>Henning, R</creatorcontrib><creatorcontrib>Walko, D A</creatorcontrib><creatorcontrib>Decamp, M F</creatorcontrib><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Optics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Loether, A</au><au>Adams, B W</au><au>Dicharia, A</au><au>Gao, Y</au><au>Henning, R</au><au>Walko, D A</au><au>Decamp, M F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pump-probe spectrometer for measuring x-rayinduced strain</atitle><jtitle>Optics letters</jtitle><date>2016-05-01</date><risdate>2016</risdate><volume>41</volume><issue>9</issue><spage>1977</spage><epage>1980</epage><pages>1977-1980</pages><issn>0146-9592</issn><eissn>1539-4794</eissn><abstract>A hard x-ray pump-probe spectrometer using a multi-crystal Bragg reflector is demonstrated at a third generation synchrotron source. This device derives both broadband pump and monochromatic probe pulses directly from a single intense, broadband x-ray pulse centered at 8.767 keV. We present a proof-of-concept experiment which directly measures x-ray induced crystalline lattice strain.</abstract><doi>10.1364/OL.41.001977</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0146-9592 |
ispartof | Optics letters, 2016-05, Vol.41 (9), p.1977-1980 |
issn | 0146-9592 1539-4794 |
language | eng |
recordid | cdi_proquest_miscellaneous_1864532104 |
source | Optica Publishing Group Journals |
subjects | Bragg reflectors Broadband Crystal structure Pumps Spectrometers Synchrotrons X-ray sources X-rays |
title | Pump-probe spectrometer for measuring x-rayinduced strain |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T16%3A01%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pump-probe%20spectrometer%20for%20measuring%20x-rayinduced%20strain&rft.jtitle=Optics%20letters&rft.au=Loether,%20A&rft.date=2016-05-01&rft.volume=41&rft.issue=9&rft.spage=1977&rft.epage=1980&rft.pages=1977-1980&rft.issn=0146-9592&rft.eissn=1539-4794&rft_id=info:doi/10.1364/OL.41.001977&rft_dat=%3Cproquest%3E1864532104%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1864532104&rft_id=info:pmid/&rfr_iscdi=true |