Formation of High-Frequency Impulses in a High-Power Magnetotherapeutic Apparatus

We describe here a novel method for forming magnetic field impulses for a high-power medical magnetotherapy apparatus. We present a block diagram of the apparatus for forming magnetic field impulses with specified parameters: rate of impulse rising front, impulse frequency, and magnetic field induct...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical engineering 2016-11, Vol.50 (4), p.262-265
Hauptverfasser: Antsygin, I. N., Gladkov, A. O., Khokhlov, K. O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 265
container_issue 4
container_start_page 262
container_title Biomedical engineering
container_volume 50
creator Antsygin, I. N.
Gladkov, A. O.
Khokhlov, K. O.
description We describe here a novel method for forming magnetic field impulses for a high-power medical magnetotherapy apparatus. We present a block diagram of the apparatus for forming magnetic field impulses with specified parameters: rate of impulse rising front, impulse frequency, and magnetic field induction amplitude. The characteristics of solenoids are given, along with calculations of various device parameters.
doi_str_mv 10.1007/s10527-016-9634-y
format Article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1864530832</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A498943877</galeid><sourcerecordid>A498943877</sourcerecordid><originalsourceid>FETCH-LOGICAL-c560y-eefc12941df7068b93679542334b5e5d97d038899a24955dc7cb5efbc0d74db23</originalsourceid><addsrcrecordid>eNqNkkuLFDEURgtRsB39Ae4K3OgiY96PZTPYTsOI73VIp1I1GbqSMkkx1r83TbmYFgXJIuTmnMu98DXNSwQvEYTibUaQYQEg4kBxQsHyqNkgJgiQmPHHzQZCyAEhSj5tnuV8V59MSrxpPu9iGk3xMbSxb6_9cAt2yf2YXbBLux-n-Zhdbn1ozfr5Kd671H4wQ3AllluXzOTm4m27nSaTTJnz8-ZJb6r14vd90Xzfvft2dQ1uPr7fX21vgGUcLsC53iKsKOp6Abk8KMKFYhQTQg_MsU6JDhIplTKYKsY6K2yt9wcLO0G7AyYXzeu175RinTcXPfps3fFogotz1khyygiU5H9QyonCgsGKvvoDvYtzCnURjRTmSkkoHlCDOTrtQx9LMvbUVG-pkooSKUSlLv9C1dO50dsYXO9r_Ux4cyZUprifZTBzznr_9cs5i1bWpphzcr2ekh9NWjSC-hQJvUZC10joUyT0Uh28OrmyYXDpwXL_lH4ByLm2Hw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1926998070</pqid></control><display><type>article</type><title>Formation of High-Frequency Impulses in a High-Power Magnetotherapeutic Apparatus</title><source>SpringerNature Journals</source><creator>Antsygin, I. N. ; Gladkov, A. O. ; Khokhlov, K. O.</creator><creatorcontrib>Antsygin, I. N. ; Gladkov, A. O. ; Khokhlov, K. O.</creatorcontrib><description>We describe here a novel method for forming magnetic field impulses for a high-power medical magnetotherapy apparatus. We present a block diagram of the apparatus for forming magnetic field impulses with specified parameters: rate of impulse rising front, impulse frequency, and magnetic field induction amplitude. The characteristics of solenoids are given, along with calculations of various device parameters.</description><identifier>ISSN: 0006-3398</identifier><identifier>EISSN: 1573-8256</identifier><identifier>DOI: 10.1007/s10527-016-9634-y</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Biomaterials ; Biomedical Engineering and Bioengineering ; Devices ; Electromagnetism ; Engineering ; Forming ; Impulses ; Magnetic fields ; Magnetic induction ; Magnetization ; Mathematical analysis ; Medical equipment ; Parameters ; Solenoids</subject><ispartof>Biomedical engineering, 2016-11, Vol.50 (4), p.262-265</ispartof><rights>Springer Science+Business Media New York 2016</rights><rights>COPYRIGHT 2016 Springer</rights><rights>Springer Science+Business Media New York 2016.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s10527-016-9634-y$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s10527-016-9634-y$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>315,781,785,27928,27929,41492,42561,51323</link.rule.ids></links><search><creatorcontrib>Antsygin, I. N.</creatorcontrib><creatorcontrib>Gladkov, A. O.</creatorcontrib><creatorcontrib>Khokhlov, K. O.</creatorcontrib><title>Formation of High-Frequency Impulses in a High-Power Magnetotherapeutic Apparatus</title><title>Biomedical engineering</title><addtitle>Biomed Eng</addtitle><description>We describe here a novel method for forming magnetic field impulses for a high-power medical magnetotherapy apparatus. We present a block diagram of the apparatus for forming magnetic field impulses with specified parameters: rate of impulse rising front, impulse frequency, and magnetic field induction amplitude. The characteristics of solenoids are given, along with calculations of various device parameters.</description><subject>Biomaterials</subject><subject>Biomedical Engineering and Bioengineering</subject><subject>Devices</subject><subject>Electromagnetism</subject><subject>Engineering</subject><subject>Forming</subject><subject>Impulses</subject><subject>Magnetic fields</subject><subject>Magnetic induction</subject><subject>Magnetization</subject><subject>Mathematical analysis</subject><subject>Medical equipment</subject><subject>Parameters</subject><subject>Solenoids</subject><issn>0006-3398</issn><issn>1573-8256</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqNkkuLFDEURgtRsB39Ae4K3OgiY96PZTPYTsOI73VIp1I1GbqSMkkx1r83TbmYFgXJIuTmnMu98DXNSwQvEYTibUaQYQEg4kBxQsHyqNkgJgiQmPHHzQZCyAEhSj5tnuV8V59MSrxpPu9iGk3xMbSxb6_9cAt2yf2YXbBLux-n-Zhdbn1ozfr5Kd671H4wQ3AllluXzOTm4m27nSaTTJnz8-ZJb6r14vd90Xzfvft2dQ1uPr7fX21vgGUcLsC53iKsKOp6Abk8KMKFYhQTQg_MsU6JDhIplTKYKsY6K2yt9wcLO0G7AyYXzeu175RinTcXPfps3fFogotz1khyygiU5H9QyonCgsGKvvoDvYtzCnURjRTmSkkoHlCDOTrtQx9LMvbUVG-pkooSKUSlLv9C1dO50dsYXO9r_Ux4cyZUprifZTBzznr_9cs5i1bWpphzcr2ekh9NWjSC-hQJvUZC10joUyT0Uh28OrmyYXDpwXL_lH4ByLm2Hw</recordid><startdate>20161101</startdate><enddate>20161101</enddate><creator>Antsygin, I. N.</creator><creator>Gladkov, A. O.</creator><creator>Khokhlov, K. O.</creator><general>Springer US</general><general>Springer</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ISR</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>L6V</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>M7S</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7TB</scope><scope>7U5</scope><scope>F28</scope><scope>L7M</scope></search><sort><creationdate>20161101</creationdate><title>Formation of High-Frequency Impulses in a High-Power Magnetotherapeutic Apparatus</title><author>Antsygin, I. N. ; Gladkov, A. O. ; Khokhlov, K. O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c560y-eefc12941df7068b93679542334b5e5d97d038899a24955dc7cb5efbc0d74db23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Biomaterials</topic><topic>Biomedical Engineering and Bioengineering</topic><topic>Devices</topic><topic>Electromagnetism</topic><topic>Engineering</topic><topic>Forming</topic><topic>Impulses</topic><topic>Magnetic fields</topic><topic>Magnetic induction</topic><topic>Magnetization</topic><topic>Mathematical analysis</topic><topic>Medical equipment</topic><topic>Parameters</topic><topic>Solenoids</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Antsygin, I. N.</creatorcontrib><creatorcontrib>Gladkov, A. O.</creatorcontrib><creatorcontrib>Khokhlov, K. O.</creatorcontrib><collection>CrossRef</collection><collection>Gale In Context: Science</collection><collection>ProQuest Central (Corporate)</collection><collection>Proquest Nursing &amp; Allied Health Source</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>ProQuest Engineering Collection</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Engineering Database</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Antsygin, I. N.</au><au>Gladkov, A. O.</au><au>Khokhlov, K. O.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Formation of High-Frequency Impulses in a High-Power Magnetotherapeutic Apparatus</atitle><jtitle>Biomedical engineering</jtitle><stitle>Biomed Eng</stitle><date>2016-11-01</date><risdate>2016</risdate><volume>50</volume><issue>4</issue><spage>262</spage><epage>265</epage><pages>262-265</pages><issn>0006-3398</issn><eissn>1573-8256</eissn><abstract>We describe here a novel method for forming magnetic field impulses for a high-power medical magnetotherapy apparatus. We present a block diagram of the apparatus for forming magnetic field impulses with specified parameters: rate of impulse rising front, impulse frequency, and magnetic field induction amplitude. The characteristics of solenoids are given, along with calculations of various device parameters.</abstract><cop>New York</cop><pub>Springer US</pub><doi>10.1007/s10527-016-9634-y</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0006-3398
ispartof Biomedical engineering, 2016-11, Vol.50 (4), p.262-265
issn 0006-3398
1573-8256
language eng
recordid cdi_proquest_miscellaneous_1864530832
source SpringerNature Journals
subjects Biomaterials
Biomedical Engineering and Bioengineering
Devices
Electromagnetism
Engineering
Forming
Impulses
Magnetic fields
Magnetic induction
Magnetization
Mathematical analysis
Medical equipment
Parameters
Solenoids
title Formation of High-Frequency Impulses in a High-Power Magnetotherapeutic Apparatus
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T10%3A30%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Formation%20of%20High-Frequency%20Impulses%20in%20a%20High-Power%20Magnetotherapeutic%20Apparatus&rft.jtitle=Biomedical%20engineering&rft.au=Antsygin,%20I.%20N.&rft.date=2016-11-01&rft.volume=50&rft.issue=4&rft.spage=262&rft.epage=265&rft.pages=262-265&rft.issn=0006-3398&rft.eissn=1573-8256&rft_id=info:doi/10.1007/s10527-016-9634-y&rft_dat=%3Cgale_proqu%3EA498943877%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1926998070&rft_id=info:pmid/&rft_galeid=A498943877&rfr_iscdi=true