The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations

Abstract Introduction The aim of this study was to assess the accuracy of the Dentaport ZX (Morita Co, Kyoto, Japan) and the Rootor (Meta Biomed, Cheongwon-gun, Korea) electronic apex locators (EALs) in detecting root perforations in dry conditions and in the presence of the following irrigation sol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of endodontics 2017-03, Vol.43 (3), p.439-442
Hauptverfasser: Altunbaş, Demet, DDS, PhD, Kuştarcı, Alper, DDS, PhD, Toyoğlu, Mustafa, DDS, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 442
container_issue 3
container_start_page 439
container_title Journal of endodontics
container_volume 43
creator Altunbaş, Demet, DDS, PhD
Kuştarcı, Alper, DDS, PhD
Toyoğlu, Mustafa, DDS, PhD
description Abstract Introduction The aim of this study was to assess the accuracy of the Dentaport ZX (Morita Co, Kyoto, Japan) and the Rootor (Meta Biomed, Cheongwon-gun, Korea) electronic apex locators (EALs) in detecting root perforations in dry conditions and in the presence of the following irrigation solutions: 2.5% sodium hypochlorite (NaOCl), 0.9% saline solution (NaCl), and 17% EDTA. Methods Twenty extracted, single-rooted human teeth were perforated artificially in the middle section. The actual canal lengths (ALs) up to the perforation site were determined, and then the teeth were embedded in an alginate mold. The electronic measurements of the perforations were obtained using a size 20 K-file by each EAL in various conditions. For each tooth, the AL was subtracted from the electronic length of the perforation. Statistical analyses were performed using the Friedman and Wilcoxon signed rank tests at a significance level of P  
doi_str_mv 10.1016/j.joen.2016.10.031
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1861580922</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0099239916307944</els_id><sourcerecordid>1861580922</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-d7f461fd255cbf62f726e2c253240c4c1f3f98d9b092b2c566bfc0034025b2e93</originalsourceid><addsrcrecordid>eNp9kU1v1DAQhi0EotvCH-CAfOSSxR_5soSQVlUpK61E1RauljMZF4esvdgJ6v57HG3hwIGTR-PnHWmeIeQNZ2vOeP1-WA8B_VrkOjfWTPJnZMXbpi1kVZXPyYoxpQohlToj5ykNjPFGyuYlORMtZ6UUfEUe778j3Xo7zugBabD0m4kuzIluY3QPxk-JBk-nTG0A5mjguECCXo0IUwzeAd0c8JHuApgpxESdP9XOP9A7t59HM2FPb0OY6A1GG2L-Cj69Ii-sGRO-fnovyNdPV_eXn4vdl-vt5WZXQMn5VPSNLWtue1FV0Nla2EbUKEBUUpQMSuBWWtX2qmNKdAKquu4sMCZLJqpOoJIX5N1p7iGGnzOmSe9dAhxH4zGvqXlb86rNaZFRcUIhhpQiWn2Ibm_iUXOmF-N60ItxvRhfetl4Dr19mj93e-z_Rv4ozsCHE4B5y18Oo07gFtm9i1mh7oP7__yP_8RhdNm6GX_gEdMQ5uizP811Eprpu-Xmy8l5LVmjylL-BlcTpxQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1861580922</pqid></control><display><type>article</type><title>The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><source>MEDLINE</source><creator>Altunbaş, Demet, DDS, PhD ; Kuştarcı, Alper, DDS, PhD ; Toyoğlu, Mustafa, DDS, PhD</creator><creatorcontrib>Altunbaş, Demet, DDS, PhD ; Kuştarcı, Alper, DDS, PhD ; Toyoğlu, Mustafa, DDS, PhD</creatorcontrib><description>Abstract Introduction The aim of this study was to assess the accuracy of the Dentaport ZX (Morita Co, Kyoto, Japan) and the Rootor (Meta Biomed, Cheongwon-gun, Korea) electronic apex locators (EALs) in detecting root perforations in dry conditions and in the presence of the following irrigation solutions: 2.5% sodium hypochlorite (NaOCl), 0.9% saline solution (NaCl), and 17% EDTA. Methods Twenty extracted, single-rooted human teeth were perforated artificially in the middle section. The actual canal lengths (ALs) up to the perforation site were determined, and then the teeth were embedded in an alginate mold. The electronic measurements of the perforations were obtained using a size 20 K-file by each EAL in various conditions. For each tooth, the AL was subtracted from the electronic length of the perforation. Statistical analyses were performed using the Friedman and Wilcoxon signed rank tests at a significance level of P  &lt; .05. Results The most accurate measurements for both EALs were obtained in dry conditions. Among the irrigation solutions in the Dentaport ZX group, EDTA gave the most accurate results, and NaOCl gave the least accurate ones. However, measurements with NaCl were closer to the AL than those obtained with EDTA for the Rootor group. Significant differences were noted among the EALs when the measurements were taken with NaOCl, NaCl, and EDTA ( P  &lt; .05). Conclusions The Dentaport ZX was more accurate compared with the Rootor in the presence of different irrigants. The content of the root canal affected the accuracy of both EALs. The most accurate measurements were obtained in dry canals.</description><identifier>ISSN: 0099-2399</identifier><identifier>EISSN: 1878-3554</identifier><identifier>DOI: 10.1016/j.joen.2016.10.031</identifier><identifier>PMID: 28104321</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Apex locator ; Dental Instruments ; Dentaport ZX ; Dentistry ; Endocrinology &amp; Metabolism ; Humans ; irrigant ; Root Canal Irrigants ; root perforation ; Rootor ; Tooth Apex ; Tooth Diseases - diagnosis ; Tooth Root - pathology</subject><ispartof>Journal of endodontics, 2017-03, Vol.43 (3), p.439-442</ispartof><rights>American Association of Endodontists</rights><rights>2016 American Association of Endodontists</rights><rights>Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-d7f461fd255cbf62f726e2c253240c4c1f3f98d9b092b2c566bfc0034025b2e93</citedby><cites>FETCH-LOGICAL-c411t-d7f461fd255cbf62f726e2c253240c4c1f3f98d9b092b2c566bfc0034025b2e93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.joen.2016.10.031$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3548,27922,27923,45993</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28104321$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Altunbaş, Demet, DDS, PhD</creatorcontrib><creatorcontrib>Kuştarcı, Alper, DDS, PhD</creatorcontrib><creatorcontrib>Toyoğlu, Mustafa, DDS, PhD</creatorcontrib><title>The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations</title><title>Journal of endodontics</title><addtitle>J Endod</addtitle><description>Abstract Introduction The aim of this study was to assess the accuracy of the Dentaport ZX (Morita Co, Kyoto, Japan) and the Rootor (Meta Biomed, Cheongwon-gun, Korea) electronic apex locators (EALs) in detecting root perforations in dry conditions and in the presence of the following irrigation solutions: 2.5% sodium hypochlorite (NaOCl), 0.9% saline solution (NaCl), and 17% EDTA. Methods Twenty extracted, single-rooted human teeth were perforated artificially in the middle section. The actual canal lengths (ALs) up to the perforation site were determined, and then the teeth were embedded in an alginate mold. The electronic measurements of the perforations were obtained using a size 20 K-file by each EAL in various conditions. For each tooth, the AL was subtracted from the electronic length of the perforation. Statistical analyses were performed using the Friedman and Wilcoxon signed rank tests at a significance level of P  &lt; .05. Results The most accurate measurements for both EALs were obtained in dry conditions. Among the irrigation solutions in the Dentaport ZX group, EDTA gave the most accurate results, and NaOCl gave the least accurate ones. However, measurements with NaCl were closer to the AL than those obtained with EDTA for the Rootor group. Significant differences were noted among the EALs when the measurements were taken with NaOCl, NaCl, and EDTA ( P  &lt; .05). Conclusions The Dentaport ZX was more accurate compared with the Rootor in the presence of different irrigants. The content of the root canal affected the accuracy of both EALs. The most accurate measurements were obtained in dry canals.</description><subject>Apex locator</subject><subject>Dental Instruments</subject><subject>Dentaport ZX</subject><subject>Dentistry</subject><subject>Endocrinology &amp; Metabolism</subject><subject>Humans</subject><subject>irrigant</subject><subject>Root Canal Irrigants</subject><subject>root perforation</subject><subject>Rootor</subject><subject>Tooth Apex</subject><subject>Tooth Diseases - diagnosis</subject><subject>Tooth Root - pathology</subject><issn>0099-2399</issn><issn>1878-3554</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kU1v1DAQhi0EotvCH-CAfOSSxR_5soSQVlUpK61E1RauljMZF4esvdgJ6v57HG3hwIGTR-PnHWmeIeQNZ2vOeP1-WA8B_VrkOjfWTPJnZMXbpi1kVZXPyYoxpQohlToj5ykNjPFGyuYlORMtZ6UUfEUe778j3Xo7zugBabD0m4kuzIluY3QPxk-JBk-nTG0A5mjguECCXo0IUwzeAd0c8JHuApgpxESdP9XOP9A7t59HM2FPb0OY6A1GG2L-Cj69Ii-sGRO-fnovyNdPV_eXn4vdl-vt5WZXQMn5VPSNLWtue1FV0Nla2EbUKEBUUpQMSuBWWtX2qmNKdAKquu4sMCZLJqpOoJIX5N1p7iGGnzOmSe9dAhxH4zGvqXlb86rNaZFRcUIhhpQiWn2Ibm_iUXOmF-N60ItxvRhfetl4Dr19mj93e-z_Rv4ozsCHE4B5y18Oo07gFtm9i1mh7oP7__yP_8RhdNm6GX_gEdMQ5uizP811Eprpu-Xmy8l5LVmjylL-BlcTpxQ</recordid><startdate>20170301</startdate><enddate>20170301</enddate><creator>Altunbaş, Demet, DDS, PhD</creator><creator>Kuştarcı, Alper, DDS, PhD</creator><creator>Toyoğlu, Mustafa, DDS, PhD</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20170301</creationdate><title>The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations</title><author>Altunbaş, Demet, DDS, PhD ; Kuştarcı, Alper, DDS, PhD ; Toyoğlu, Mustafa, DDS, PhD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-d7f461fd255cbf62f726e2c253240c4c1f3f98d9b092b2c566bfc0034025b2e93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Apex locator</topic><topic>Dental Instruments</topic><topic>Dentaport ZX</topic><topic>Dentistry</topic><topic>Endocrinology &amp; Metabolism</topic><topic>Humans</topic><topic>irrigant</topic><topic>Root Canal Irrigants</topic><topic>root perforation</topic><topic>Rootor</topic><topic>Tooth Apex</topic><topic>Tooth Diseases - diagnosis</topic><topic>Tooth Root - pathology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Altunbaş, Demet, DDS, PhD</creatorcontrib><creatorcontrib>Kuştarcı, Alper, DDS, PhD</creatorcontrib><creatorcontrib>Toyoğlu, Mustafa, DDS, PhD</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of endodontics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Altunbaş, Demet, DDS, PhD</au><au>Kuştarcı, Alper, DDS, PhD</au><au>Toyoğlu, Mustafa, DDS, PhD</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations</atitle><jtitle>Journal of endodontics</jtitle><addtitle>J Endod</addtitle><date>2017-03-01</date><risdate>2017</risdate><volume>43</volume><issue>3</issue><spage>439</spage><epage>442</epage><pages>439-442</pages><issn>0099-2399</issn><eissn>1878-3554</eissn><abstract>Abstract Introduction The aim of this study was to assess the accuracy of the Dentaport ZX (Morita Co, Kyoto, Japan) and the Rootor (Meta Biomed, Cheongwon-gun, Korea) electronic apex locators (EALs) in detecting root perforations in dry conditions and in the presence of the following irrigation solutions: 2.5% sodium hypochlorite (NaOCl), 0.9% saline solution (NaCl), and 17% EDTA. Methods Twenty extracted, single-rooted human teeth were perforated artificially in the middle section. The actual canal lengths (ALs) up to the perforation site were determined, and then the teeth were embedded in an alginate mold. The electronic measurements of the perforations were obtained using a size 20 K-file by each EAL in various conditions. For each tooth, the AL was subtracted from the electronic length of the perforation. Statistical analyses were performed using the Friedman and Wilcoxon signed rank tests at a significance level of P  &lt; .05. Results The most accurate measurements for both EALs were obtained in dry conditions. Among the irrigation solutions in the Dentaport ZX group, EDTA gave the most accurate results, and NaOCl gave the least accurate ones. However, measurements with NaCl were closer to the AL than those obtained with EDTA for the Rootor group. Significant differences were noted among the EALs when the measurements were taken with NaOCl, NaCl, and EDTA ( P  &lt; .05). Conclusions The Dentaport ZX was more accurate compared with the Rootor in the presence of different irrigants. The content of the root canal affected the accuracy of both EALs. The most accurate measurements were obtained in dry canals.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>28104321</pmid><doi>10.1016/j.joen.2016.10.031</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0099-2399
ispartof Journal of endodontics, 2017-03, Vol.43 (3), p.439-442
issn 0099-2399
1878-3554
language eng
recordid cdi_proquest_miscellaneous_1861580922
source Elsevier ScienceDirect Journals Complete - AutoHoldings; MEDLINE
subjects Apex locator
Dental Instruments
Dentaport ZX
Dentistry
Endocrinology & Metabolism
Humans
irrigant
Root Canal Irrigants
root perforation
Rootor
Tooth Apex
Tooth Diseases - diagnosis
Tooth Root - pathology
title The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T06%3A42%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Influence%20of%20Various%20Irrigants%20on%20the%20Accuracy%20of%202%20Electronic%20Apex%20Locators%20in%20Locating%20Simulated%20Root%20Perforations&rft.jtitle=Journal%20of%20endodontics&rft.au=Altunba%C5%9F,%20Demet,%20DDS,%20PhD&rft.date=2017-03-01&rft.volume=43&rft.issue=3&rft.spage=439&rft.epage=442&rft.pages=439-442&rft.issn=0099-2399&rft.eissn=1878-3554&rft_id=info:doi/10.1016/j.joen.2016.10.031&rft_dat=%3Cproquest_cross%3E1861580922%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1861580922&rft_id=info:pmid/28104321&rft_els_id=1_s2_0_S0099239916307944&rfr_iscdi=true