A portable, non-focusing optics spectrophotometer (NoFOSpec) for measurements of steady-state absorbance changes in intact plants
Kinetically-resolved absorbance measurements during extended, or steady-state illumination are typically hindered by large, light-induced changes in the light-scattering properties of the material. In this work, a new type of portable spectrophotometer, the Non-Focusing Optical Spectrophotometer (No...
Gespeichert in:
Veröffentlicht in: | Photosynthesis research 2001-01, Vol.70 (2), p.231-240 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 240 |
---|---|
container_issue | 2 |
container_start_page | 231 |
container_title | Photosynthesis research |
container_volume | 70 |
creator | Sacksteder, C A Jacoby, M E Kramer, D M |
description | Kinetically-resolved absorbance measurements during extended, or steady-state illumination are typically hindered by large, light-induced changes in the light-scattering properties of the material. In this work, a new type of portable spectrophotometer, the Non-Focusing Optical Spectrophotometer (NoFOSpec), is introduced, which reduces interference from light-scattering changes and is in a form suitable for fieldwork. The instrument employs a non-focusing optical component, called a compound parabolic concentrator (CPC), to simultaneously concentrate and homogeneously diffuse measuring and actinic light (from light-emitting diode sources) onto the leaf sample. Light passing through the sample is then collected and processed using a subsequent series of CPCs leading to a photodiode detector. The instrument is designed to be compact, lightweight and rugged for field work. The pulsed measuring beam allows for high sensitivity (typically < 100 ppm noise) and time resolution ( approximately 10 mus) measurements in the visible and near infrared spectral regions. These attributes allow high-resolution measurements of signals associated with energization of the thylakoid membrane (the electrochromic shifting of carotenoid pigments), as well as electron transfer, e.g., the 820-nm changes associated with electron transfer through Photosystem I (PS I). In addition, the instrument can be used as a kinetic fluorimeter, e.g., to measure saturation-pulse fluorescence changes indicative of Photosystem II (PS II) quantum efficiency. The instrument is demonstrated by estimating electron and proton fluxes through the photosynthetic apparatus in an intact tobacco leaf, using respectively the saturation-pulse fluorescence changes and dark-interval relaxation kinetics (DIRK) of the electrochromic shift. A linear relationship was found, confirming our earlier results with the laboratory-based diffused-optics flash spectrophotometer, indicating a constant H(+)/e(-) stoichiometry for linear electron transfer, and suggesting that cyclic electron flow around PS I is either negligible or proportional to linear electron flow. This type of measurement should be useful under field conditions for estimating the extent of PS I cyclic electron transfer, which is proposed to operate under stressed conditions. |
doi_str_mv | 10.1023/A:1017906626288 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1859497540</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2145765371</sourcerecordid><originalsourceid>FETCH-LOGICAL-p236t-f1110a46061cf7a009a923e6a4b765edc5bf2f27133eebd9d88de6c22d3c564c3</originalsourceid><addsrcrecordid>eNpdkM9LwzAcxYMobk7P3iR4mmA1P5o09TaGU2G4g3ouafrt1tEmNUkPO_qfW1AvwhcefPm8x-MhdEnJHSWM3y8eKKFZTqRkkil1hKZUZDwRJMuP0ZRQKRMlcjFBZyHsCSFKUn6KJlQypriQU_S1wL3zUZct3GLrbFI7M4TGbrHrY2MCDj2Y6F2_c9F1EMHj-atbbd7G9w2unccd6DB46MDGgF2NQwRdHZIQdQSsy-B8qa0BbHbabiHgxo4XtYm4b_XoOUcntW4DXPzqDH2sHt-Xz8l68_SyXKyTnnEZk5pSSnQqiaSmzjQhuc4ZB6nTMpMCKiPKmtUso5wDlFVeKVWBNIxV3AiZGj5D85_c3rvPAUIsuiYYaMcS4IZQ0HGoNM9ESkb0-h-6d4O3Y7siE1wpnop0hK5-oaHsoCp633TaH4q_bfk3QV987g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>753883454</pqid></control><display><type>article</type><title>A portable, non-focusing optics spectrophotometer (NoFOSpec) for measurements of steady-state absorbance changes in intact plants</title><source>SpringerLink Journals - AutoHoldings</source><creator>Sacksteder, C A ; Jacoby, M E ; Kramer, D M</creator><creatorcontrib>Sacksteder, C A ; Jacoby, M E ; Kramer, D M</creatorcontrib><description>Kinetically-resolved absorbance measurements during extended, or steady-state illumination are typically hindered by large, light-induced changes in the light-scattering properties of the material. In this work, a new type of portable spectrophotometer, the Non-Focusing Optical Spectrophotometer (NoFOSpec), is introduced, which reduces interference from light-scattering changes and is in a form suitable for fieldwork. The instrument employs a non-focusing optical component, called a compound parabolic concentrator (CPC), to simultaneously concentrate and homogeneously diffuse measuring and actinic light (from light-emitting diode sources) onto the leaf sample. Light passing through the sample is then collected and processed using a subsequent series of CPCs leading to a photodiode detector. The instrument is designed to be compact, lightweight and rugged for field work. The pulsed measuring beam allows for high sensitivity (typically < 100 ppm noise) and time resolution ( approximately 10 mus) measurements in the visible and near infrared spectral regions. These attributes allow high-resolution measurements of signals associated with energization of the thylakoid membrane (the electrochromic shifting of carotenoid pigments), as well as electron transfer, e.g., the 820-nm changes associated with electron transfer through Photosystem I (PS I). In addition, the instrument can be used as a kinetic fluorimeter, e.g., to measure saturation-pulse fluorescence changes indicative of Photosystem II (PS II) quantum efficiency. The instrument is demonstrated by estimating electron and proton fluxes through the photosynthetic apparatus in an intact tobacco leaf, using respectively the saturation-pulse fluorescence changes and dark-interval relaxation kinetics (DIRK) of the electrochromic shift. A linear relationship was found, confirming our earlier results with the laboratory-based diffused-optics flash spectrophotometer, indicating a constant H(+)/e(-) stoichiometry for linear electron transfer, and suggesting that cyclic electron flow around PS I is either negligible or proportional to linear electron flow. This type of measurement should be useful under field conditions for estimating the extent of PS I cyclic electron transfer, which is proposed to operate under stressed conditions.</description><identifier>ISSN: 0166-8595</identifier><identifier>EISSN: 1573-5079</identifier><identifier>DOI: 10.1023/A:1017906626288</identifier><identifier>PMID: 16228356</identifier><language>eng</language><publisher>Netherlands: Springer Nature B.V</publisher><subject>Field study ; Light</subject><ispartof>Photosynthesis research, 2001-01, Vol.70 (2), p.231-240</ispartof><rights>Kluwer Academic Publishers 2001</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16228356$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sacksteder, C A</creatorcontrib><creatorcontrib>Jacoby, M E</creatorcontrib><creatorcontrib>Kramer, D M</creatorcontrib><title>A portable, non-focusing optics spectrophotometer (NoFOSpec) for measurements of steady-state absorbance changes in intact plants</title><title>Photosynthesis research</title><addtitle>Photosynth Res</addtitle><description>Kinetically-resolved absorbance measurements during extended, or steady-state illumination are typically hindered by large, light-induced changes in the light-scattering properties of the material. In this work, a new type of portable spectrophotometer, the Non-Focusing Optical Spectrophotometer (NoFOSpec), is introduced, which reduces interference from light-scattering changes and is in a form suitable for fieldwork. The instrument employs a non-focusing optical component, called a compound parabolic concentrator (CPC), to simultaneously concentrate and homogeneously diffuse measuring and actinic light (from light-emitting diode sources) onto the leaf sample. Light passing through the sample is then collected and processed using a subsequent series of CPCs leading to a photodiode detector. The instrument is designed to be compact, lightweight and rugged for field work. The pulsed measuring beam allows for high sensitivity (typically < 100 ppm noise) and time resolution ( approximately 10 mus) measurements in the visible and near infrared spectral regions. These attributes allow high-resolution measurements of signals associated with energization of the thylakoid membrane (the electrochromic shifting of carotenoid pigments), as well as electron transfer, e.g., the 820-nm changes associated with electron transfer through Photosystem I (PS I). In addition, the instrument can be used as a kinetic fluorimeter, e.g., to measure saturation-pulse fluorescence changes indicative of Photosystem II (PS II) quantum efficiency. The instrument is demonstrated by estimating electron and proton fluxes through the photosynthetic apparatus in an intact tobacco leaf, using respectively the saturation-pulse fluorescence changes and dark-interval relaxation kinetics (DIRK) of the electrochromic shift. A linear relationship was found, confirming our earlier results with the laboratory-based diffused-optics flash spectrophotometer, indicating a constant H(+)/e(-) stoichiometry for linear electron transfer, and suggesting that cyclic electron flow around PS I is either negligible or proportional to linear electron flow. This type of measurement should be useful under field conditions for estimating the extent of PS I cyclic electron transfer, which is proposed to operate under stressed conditions.</description><subject>Field study</subject><subject>Light</subject><issn>0166-8595</issn><issn>1573-5079</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNpdkM9LwzAcxYMobk7P3iR4mmA1P5o09TaGU2G4g3ouafrt1tEmNUkPO_qfW1AvwhcefPm8x-MhdEnJHSWM3y8eKKFZTqRkkil1hKZUZDwRJMuP0ZRQKRMlcjFBZyHsCSFKUn6KJlQypriQU_S1wL3zUZct3GLrbFI7M4TGbrHrY2MCDj2Y6F2_c9F1EMHj-atbbd7G9w2unccd6DB46MDGgF2NQwRdHZIQdQSsy-B8qa0BbHbabiHgxo4XtYm4b_XoOUcntW4DXPzqDH2sHt-Xz8l68_SyXKyTnnEZk5pSSnQqiaSmzjQhuc4ZB6nTMpMCKiPKmtUso5wDlFVeKVWBNIxV3AiZGj5D85_c3rvPAUIsuiYYaMcS4IZQ0HGoNM9ESkb0-h-6d4O3Y7siE1wpnop0hK5-oaHsoCp633TaH4q_bfk3QV987g</recordid><startdate>20010101</startdate><enddate>20010101</enddate><creator>Sacksteder, C A</creator><creator>Jacoby, M E</creator><creator>Kramer, D M</creator><general>Springer Nature B.V</general><scope>NPM</scope><scope>3V.</scope><scope>7QP</scope><scope>7X7</scope><scope>7XB</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8AO</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7N</scope><scope>M7P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope></search><sort><creationdate>20010101</creationdate><title>A portable, non-focusing optics spectrophotometer (NoFOSpec) for measurements of steady-state absorbance changes in intact plants</title><author>Sacksteder, C A ; Jacoby, M E ; Kramer, D M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p236t-f1110a46061cf7a009a923e6a4b765edc5bf2f27133eebd9d88de6c22d3c564c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Field study</topic><topic>Light</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sacksteder, C A</creatorcontrib><creatorcontrib>Jacoby, M E</creatorcontrib><creatorcontrib>Kramer, D M</creatorcontrib><collection>PubMed</collection><collection>ProQuest Central (Corporate)</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Biological Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><jtitle>Photosynthesis research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sacksteder, C A</au><au>Jacoby, M E</au><au>Kramer, D M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A portable, non-focusing optics spectrophotometer (NoFOSpec) for measurements of steady-state absorbance changes in intact plants</atitle><jtitle>Photosynthesis research</jtitle><addtitle>Photosynth Res</addtitle><date>2001-01-01</date><risdate>2001</risdate><volume>70</volume><issue>2</issue><spage>231</spage><epage>240</epage><pages>231-240</pages><issn>0166-8595</issn><eissn>1573-5079</eissn><abstract>Kinetically-resolved absorbance measurements during extended, or steady-state illumination are typically hindered by large, light-induced changes in the light-scattering properties of the material. In this work, a new type of portable spectrophotometer, the Non-Focusing Optical Spectrophotometer (NoFOSpec), is introduced, which reduces interference from light-scattering changes and is in a form suitable for fieldwork. The instrument employs a non-focusing optical component, called a compound parabolic concentrator (CPC), to simultaneously concentrate and homogeneously diffuse measuring and actinic light (from light-emitting diode sources) onto the leaf sample. Light passing through the sample is then collected and processed using a subsequent series of CPCs leading to a photodiode detector. The instrument is designed to be compact, lightweight and rugged for field work. The pulsed measuring beam allows for high sensitivity (typically < 100 ppm noise) and time resolution ( approximately 10 mus) measurements in the visible and near infrared spectral regions. These attributes allow high-resolution measurements of signals associated with energization of the thylakoid membrane (the electrochromic shifting of carotenoid pigments), as well as electron transfer, e.g., the 820-nm changes associated with electron transfer through Photosystem I (PS I). In addition, the instrument can be used as a kinetic fluorimeter, e.g., to measure saturation-pulse fluorescence changes indicative of Photosystem II (PS II) quantum efficiency. The instrument is demonstrated by estimating electron and proton fluxes through the photosynthetic apparatus in an intact tobacco leaf, using respectively the saturation-pulse fluorescence changes and dark-interval relaxation kinetics (DIRK) of the electrochromic shift. A linear relationship was found, confirming our earlier results with the laboratory-based diffused-optics flash spectrophotometer, indicating a constant H(+)/e(-) stoichiometry for linear electron transfer, and suggesting that cyclic electron flow around PS I is either negligible or proportional to linear electron flow. This type of measurement should be useful under field conditions for estimating the extent of PS I cyclic electron transfer, which is proposed to operate under stressed conditions.</abstract><cop>Netherlands</cop><pub>Springer Nature B.V</pub><pmid>16228356</pmid><doi>10.1023/A:1017906626288</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0166-8595 |
ispartof | Photosynthesis research, 2001-01, Vol.70 (2), p.231-240 |
issn | 0166-8595 1573-5079 |
language | eng |
recordid | cdi_proquest_miscellaneous_1859497540 |
source | SpringerLink Journals - AutoHoldings |
subjects | Field study Light |
title | A portable, non-focusing optics spectrophotometer (NoFOSpec) for measurements of steady-state absorbance changes in intact plants |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T07%3A08%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20portable,%20non-focusing%20optics%20spectrophotometer%20(NoFOSpec)%20for%20measurements%20of%20steady-state%20absorbance%20changes%20in%20intact%20plants&rft.jtitle=Photosynthesis%20research&rft.au=Sacksteder,%20C%20A&rft.date=2001-01-01&rft.volume=70&rft.issue=2&rft.spage=231&rft.epage=240&rft.pages=231-240&rft.issn=0166-8595&rft.eissn=1573-5079&rft_id=info:doi/10.1023/A:1017906626288&rft_dat=%3Cproquest_pubme%3E2145765371%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=753883454&rft_id=info:pmid/16228356&rfr_iscdi=true |