Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer

Results of a systematic study concerning non-spectral interferences observed with a commercially available high resolution ICP-mass spectrometer are reported and compared to observations made with a quadrupole-based instrument. In general, matrix effects were observed to be to a large extent compara...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 1996-06, Vol.355 (3-4), p.397-400
Hauptverfasser: VANHAECKE, F, RIONDATO, J, MOENS, L, DAMS, R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 400
container_issue 3-4
container_start_page 397
container_title Analytical and bioanalytical chemistry
container_volume 355
creator VANHAECKE, F
RIONDATO, J
MOENS, L
DAMS, R
description Results of a systematic study concerning non-spectral interferences observed with a commercially available high resolution ICP-mass spectrometer are reported and compared to observations made with a quadrupole-based instrument. In general, matrix effects were observed to be to a large extent comparable for both instruments used. In all cases, the matrix-induced signal suppression or enhancement was seen to depend in a regular way on the mass number of the nuclides monitored. In most cases, the ionization potential of the nuclides has little or no influence on the extent of suppression or enhancement. For As, Se and Te, the introduction of 2.5% ethanol, 0.5 mol/l H(2)SO(4), or to a lesser extent 0.5 mol/l H(3)PO(4), leads to an exceptional increase in the signal intensity for both instruments. Registration of signal behaviour plots (signal intensity as a function of the nebulizer gas flow rate) in different matrices revealed that both the height of the plot and the optimum nebulizer gas flow rate are a function of the matrix composition. Finally, no indication was found that the acceleration of the extracted ions over 8000 V with the high resolution instrument would lead to an alleviation of space charge effects when compared to a quadrupole-based ICP-mass spectrometer.
doi_str_mv 10.1007/s0021663550397
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1859453595</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1859453595</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322t-280188dd5206e1662192a775ddad83238f40fd55543836cee1d1886b0d8920843</originalsourceid><addsrcrecordid>eNpVkD1v2zAQhomiQe26XTMGHDp0kXP8kqgxMJLWgNFkSGaBJk8xDUp0SKlB_n1k2EjR5Q44PPfg7iXkksGSAVTXGYCzshRKgairT2TOpOAFYwI-kznUoiqgFGJGvua8hyNb8y9kxhRIJbmak_2f2Bf5gHZIJlDfD5haTNhbzHSqcTxO0NFXP-yooTZ2HSbrTQhv1Pw1PphtQLrzzzuaMMcwDj72dL16KDqTMz2ZY4eT5Ru5aE3I-P3cF-Tp7vZx9bvY3P9ar242hRWcDwXXwLR2TnEocXrteLKpKuWccVpwoVsJrVNKSaFFaRGZm_hyC07XHLQUC_Lz5D2k-DJiHprOZ4shmB7jmBumVS2VULWa0OUJtSnmnLBtDsl3Jr01DJpjvs3_-U4LV2f3uO3Q_cPPgU7AjzNgsjWhTaa3Pn9wgnEp61K8A7J2glo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1859453595</pqid></control><display><type>article</type><title>Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer</title><source>SpringerLink Journals - AutoHoldings</source><creator>VANHAECKE, F ; RIONDATO, J ; MOENS, L ; DAMS, R</creator><creatorcontrib>VANHAECKE, F ; RIONDATO, J ; MOENS, L ; DAMS, R</creatorcontrib><description>Results of a systematic study concerning non-spectral interferences observed with a commercially available high resolution ICP-mass spectrometer are reported and compared to observations made with a quadrupole-based instrument. In general, matrix effects were observed to be to a large extent comparable for both instruments used. In all cases, the matrix-induced signal suppression or enhancement was seen to depend in a regular way on the mass number of the nuclides monitored. In most cases, the ionization potential of the nuclides has little or no influence on the extent of suppression or enhancement. For As, Se and Te, the introduction of 2.5% ethanol, 0.5 mol/l H(2)SO(4), or to a lesser extent 0.5 mol/l H(3)PO(4), leads to an exceptional increase in the signal intensity for both instruments. Registration of signal behaviour plots (signal intensity as a function of the nebulizer gas flow rate) in different matrices revealed that both the height of the plot and the optimum nebulizer gas flow rate are a function of the matrix composition. Finally, no indication was found that the acceleration of the extracted ions over 8000 V with the high resolution instrument would lead to an alleviation of space charge effects when compared to a quadrupole-based ICP-mass spectrometer.</description><identifier>ISSN: 0937-0633</identifier><identifier>ISSN: 1618-2642</identifier><identifier>EISSN: 1432-1130</identifier><identifier>EISSN: 1618-2650</identifier><identifier>DOI: 10.1007/s0021663550397</identifier><identifier>PMID: 15045425</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; Spectrometric and optical methods</subject><ispartof>Analytical and bioanalytical chemistry, 1996-06, Vol.355 (3-4), p.397-400</ispartof><rights>1996 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322t-280188dd5206e1662192a775ddad83238f40fd55543836cee1d1886b0d8920843</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23929,23930,25139,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3124496$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15045425$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>VANHAECKE, F</creatorcontrib><creatorcontrib>RIONDATO, J</creatorcontrib><creatorcontrib>MOENS, L</creatorcontrib><creatorcontrib>DAMS, R</creatorcontrib><title>Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer</title><title>Analytical and bioanalytical chemistry</title><addtitle>Anal Bioanal Chem</addtitle><description>Results of a systematic study concerning non-spectral interferences observed with a commercially available high resolution ICP-mass spectrometer are reported and compared to observations made with a quadrupole-based instrument. In general, matrix effects were observed to be to a large extent comparable for both instruments used. In all cases, the matrix-induced signal suppression or enhancement was seen to depend in a regular way on the mass number of the nuclides monitored. In most cases, the ionization potential of the nuclides has little or no influence on the extent of suppression or enhancement. For As, Se and Te, the introduction of 2.5% ethanol, 0.5 mol/l H(2)SO(4), or to a lesser extent 0.5 mol/l H(3)PO(4), leads to an exceptional increase in the signal intensity for both instruments. Registration of signal behaviour plots (signal intensity as a function of the nebulizer gas flow rate) in different matrices revealed that both the height of the plot and the optimum nebulizer gas flow rate are a function of the matrix composition. Finally, no indication was found that the acceleration of the extracted ions over 8000 V with the high resolution instrument would lead to an alleviation of space charge effects when compared to a quadrupole-based ICP-mass spectrometer.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Spectrometric and optical methods</subject><issn>0937-0633</issn><issn>1618-2642</issn><issn>1432-1130</issn><issn>1618-2650</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1996</creationdate><recordtype>article</recordtype><recordid>eNpVkD1v2zAQhomiQe26XTMGHDp0kXP8kqgxMJLWgNFkSGaBJk8xDUp0SKlB_n1k2EjR5Q44PPfg7iXkksGSAVTXGYCzshRKgairT2TOpOAFYwI-kznUoiqgFGJGvua8hyNb8y9kxhRIJbmak_2f2Bf5gHZIJlDfD5haTNhbzHSqcTxO0NFXP-yooTZ2HSbrTQhv1Pw1PphtQLrzzzuaMMcwDj72dL16KDqTMz2ZY4eT5Ru5aE3I-P3cF-Tp7vZx9bvY3P9ar242hRWcDwXXwLR2TnEocXrteLKpKuWccVpwoVsJrVNKSaFFaRGZm_hyC07XHLQUC_Lz5D2k-DJiHprOZ4shmB7jmBumVS2VULWa0OUJtSnmnLBtDsl3Jr01DJpjvs3_-U4LV2f3uO3Q_cPPgU7AjzNgsjWhTaa3Pn9wgnEp61K8A7J2glo</recordid><startdate>19960601</startdate><enddate>19960601</enddate><creator>VANHAECKE, F</creator><creator>RIONDATO, J</creator><creator>MOENS, L</creator><creator>DAMS, R</creator><general>Springer</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19960601</creationdate><title>Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer</title><author>VANHAECKE, F ; RIONDATO, J ; MOENS, L ; DAMS, R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322t-280188dd5206e1662192a775ddad83238f40fd55543836cee1d1886b0d8920843</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1996</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>VANHAECKE, F</creatorcontrib><creatorcontrib>RIONDATO, J</creatorcontrib><creatorcontrib>MOENS, L</creatorcontrib><creatorcontrib>DAMS, R</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical and bioanalytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>VANHAECKE, F</au><au>RIONDATO, J</au><au>MOENS, L</au><au>DAMS, R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer</atitle><jtitle>Analytical and bioanalytical chemistry</jtitle><addtitle>Anal Bioanal Chem</addtitle><date>1996-06-01</date><risdate>1996</risdate><volume>355</volume><issue>3-4</issue><spage>397</spage><epage>400</epage><pages>397-400</pages><issn>0937-0633</issn><issn>1618-2642</issn><eissn>1432-1130</eissn><eissn>1618-2650</eissn><abstract>Results of a systematic study concerning non-spectral interferences observed with a commercially available high resolution ICP-mass spectrometer are reported and compared to observations made with a quadrupole-based instrument. In general, matrix effects were observed to be to a large extent comparable for both instruments used. In all cases, the matrix-induced signal suppression or enhancement was seen to depend in a regular way on the mass number of the nuclides monitored. In most cases, the ionization potential of the nuclides has little or no influence on the extent of suppression or enhancement. For As, Se and Te, the introduction of 2.5% ethanol, 0.5 mol/l H(2)SO(4), or to a lesser extent 0.5 mol/l H(3)PO(4), leads to an exceptional increase in the signal intensity for both instruments. Registration of signal behaviour plots (signal intensity as a function of the nebulizer gas flow rate) in different matrices revealed that both the height of the plot and the optimum nebulizer gas flow rate are a function of the matrix composition. Finally, no indication was found that the acceleration of the extracted ions over 8000 V with the high resolution instrument would lead to an alleviation of space charge effects when compared to a quadrupole-based ICP-mass spectrometer.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>15045425</pmid><doi>10.1007/s0021663550397</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0937-0633
ispartof Analytical and bioanalytical chemistry, 1996-06, Vol.355 (3-4), p.397-400
issn 0937-0633
1618-2642
1432-1130
1618-2650
language eng
recordid cdi_proquest_miscellaneous_1859453595
source SpringerLink Journals - AutoHoldings
subjects Analytical chemistry
Chemistry
Exact sciences and technology
Spectrometric and optical methods
title Non-spectral interferences encountered with a commercially available high resolution ICP-mass spectrometer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T11%3A19%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Non-spectral%20interferences%20encountered%20with%20a%20commercially%20available%20high%20resolution%20ICP-mass%20spectrometer&rft.jtitle=Analytical%20and%20bioanalytical%20chemistry&rft.au=VANHAECKE,%20F&rft.date=1996-06-01&rft.volume=355&rft.issue=3-4&rft.spage=397&rft.epage=400&rft.pages=397-400&rft.issn=0937-0633&rft.eissn=1432-1130&rft_id=info:doi/10.1007/s0021663550397&rft_dat=%3Cproquest_cross%3E1859453595%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1859453595&rft_id=info:pmid/15045425&rfr_iscdi=true