Simulation study of a novel target oriented SPECT design using a variable pinhole collimator

Purpose In the past decade, demands for organ specific (target oriented) single‐photon emission computed tomography (SPECT) is increasing, and several groups have conducted studies on developing clinical dedicated SPECT with pinhole collimator to improve the spatial resolution. However, acceptance a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2017-02, Vol.44 (2), p.470-478
Hauptverfasser: Bae, Seungbin, Chun, Jaehee, Cha, Hyemi, Yeom, Jung Yeol, Lee, Kisung, Lee, Hakjae
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 478
container_issue 2
container_start_page 470
container_title Medical physics (Lancaster)
container_volume 44
creator Bae, Seungbin
Chun, Jaehee
Cha, Hyemi
Yeom, Jung Yeol
Lee, Kisung
Lee, Hakjae
description Purpose In the past decade, demands for organ specific (target oriented) single‐photon emission computed tomography (SPECT) is increasing, and several groups have conducted studies on developing clinical dedicated SPECT with pinhole collimator to improve the spatial resolution. However, acceptance angle of the collimator cannot be adjusted to fit the different ROIs of target objects because the shape of pinhole could not be changed, and the magnifying factor cannot be maximized as the collimator‐to‐detector distance is fixed. Furthermore, those dedicated pinhole SPECTs are typically made for a single purpose and therefore possess a drawback in that it cannot be utilized for any other purpose. In this study, we propose a novel SPECT system using variable pinhole collimator (VP SPECT) whose parameters are flexible. Methods The proposed variable pinhole collimator is modeled on conventional pinhole by piling several tungsten layers of different apertures. Depending on the combination of the holes in each layer, a variety of hole diameters and acceptance angles of the pinhole can be made. In addition, VP SPECT system allows attaching the collimator to the object as close as possible to maximize the sensitivity and adjust the distance of the pinhole from the scintillation detector to optimize the system resolution for each rotation angle, automatically. For quantitative measurement, we compared the sensitivity and spatial resolution of VP SPECT with those of conventional pinhole SPECT. To determine the possibility of the clinical and preclinical use of proposed system, a digital mouse whole‐body (MOBY) phantom is used for simulating the live mouse model. Results The result of simulation using ultra‐micro hot spot phantom shows that the sensitivity of the proposed VP SPECT system is about 297% of that of the conventional system. While hot rods of diameter 0.6 mm can be distinguished in the image with the proposed VP SPECT system, 1.2‐mm hot rods are barely discernible in the conventional pinhole SPECT image. According to the result of MOBY phantom simulation, heart walls separated by 3 mm were not distinguished in conventional pinhole SPECT images, but were clearly discerned in VP SPECT images. Conclusions In this study, we designed a novel pinhole collimator for SPECT and presented preliminary results of target oriented imaging with a simulation study. Currently, we are pursuing strategies to realize the proposed system, with the goal to apply the technology in
doi_str_mv 10.1002/mp.12075
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1854107205</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1854107205</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3215-5a9fde6be1395ddbb9d377e0a0a7138aa6b6412f0aedbe0162809eb7ba59d3163</originalsourceid><addsrcrecordid>eNp1kF1LwzAYRoMobk7BXyC59KbzTdq066WM-QETB5t3QkmWtzOSNjVpJ_v3VufHlVfPzeHwcAg5ZzBmAPyqasaMQyYOyJAnWRwlHPJDMgTIk4gnIAbkJIRXAEhjAcdkwCcQ8xySIXlemqqzsjWupqHt9I66kkpauy1a2kq_wZY6b7BuUdPlYjZdUY3BbGraBVNvenQrvZHKIm1M_eL6XTtrTSVb50_JUSltwLPvHZGnm9lqehfNH2_vp9fzaB1zJiIh81JjqpDFudBaqVzHWYYgQWYsnkiZqjRhvASJWiGwtL-fo8qUFD3J0nhELvfexru3DkNbVCas0VpZo-tCwSYiYZBxEH_o2rsQPJZF4_uzflcwKD5bFlVTfLXs0Ytva6cq1L_gT7weiPbAu7G4-1dUPCz2wg8oAH0f</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1854107205</pqid></control><display><type>article</type><title>Simulation study of a novel target oriented SPECT design using a variable pinhole collimator</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Bae, Seungbin ; Chun, Jaehee ; Cha, Hyemi ; Yeom, Jung Yeol ; Lee, Kisung ; Lee, Hakjae</creator><creatorcontrib>Bae, Seungbin ; Chun, Jaehee ; Cha, Hyemi ; Yeom, Jung Yeol ; Lee, Kisung ; Lee, Hakjae</creatorcontrib><description>Purpose In the past decade, demands for organ specific (target oriented) single‐photon emission computed tomography (SPECT) is increasing, and several groups have conducted studies on developing clinical dedicated SPECT with pinhole collimator to improve the spatial resolution. However, acceptance angle of the collimator cannot be adjusted to fit the different ROIs of target objects because the shape of pinhole could not be changed, and the magnifying factor cannot be maximized as the collimator‐to‐detector distance is fixed. Furthermore, those dedicated pinhole SPECTs are typically made for a single purpose and therefore possess a drawback in that it cannot be utilized for any other purpose. In this study, we propose a novel SPECT system using variable pinhole collimator (VP SPECT) whose parameters are flexible. Methods The proposed variable pinhole collimator is modeled on conventional pinhole by piling several tungsten layers of different apertures. Depending on the combination of the holes in each layer, a variety of hole diameters and acceptance angles of the pinhole can be made. In addition, VP SPECT system allows attaching the collimator to the object as close as possible to maximize the sensitivity and adjust the distance of the pinhole from the scintillation detector to optimize the system resolution for each rotation angle, automatically. For quantitative measurement, we compared the sensitivity and spatial resolution of VP SPECT with those of conventional pinhole SPECT. To determine the possibility of the clinical and preclinical use of proposed system, a digital mouse whole‐body (MOBY) phantom is used for simulating the live mouse model. Results The result of simulation using ultra‐micro hot spot phantom shows that the sensitivity of the proposed VP SPECT system is about 297% of that of the conventional system. While hot rods of diameter 0.6 mm can be distinguished in the image with the proposed VP SPECT system, 1.2‐mm hot rods are barely discernible in the conventional pinhole SPECT image. According to the result of MOBY phantom simulation, heart walls separated by 3 mm were not distinguished in conventional pinhole SPECT images, but were clearly discerned in VP SPECT images. Conclusions In this study, we designed a novel pinhole collimator for SPECT and presented preliminary results of target oriented imaging with a simulation study. Currently, we are pursuing strategies to realize the proposed system, with the goal to apply the technology into a high‐sensitivity and high‐resolution preclinical SPECT. Should VP SPECT be applied to the clinical setting, we anticipate a high‐sensitivity, high‐resolution system for applications such as heart dedicated SPECT or related fields.</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1002/mp.12075</identifier><identifier>PMID: 28032904</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Computer Simulation ; Equipment Design ; Feasibility Studies ; Heart - diagnostic imaging ; Mice ; Models, Anatomic ; Phantoms, Imaging ; pinhole collimator ; simulation ; single‐photon emission computed tomography ; Tomography, Emission-Computed, Single-Photon - instrumentation ; Tomography, Emission-Computed, Single-Photon - methods ; Tungsten</subject><ispartof>Medical physics (Lancaster), 2017-02, Vol.44 (2), p.470-478</ispartof><rights>2016 American Association of Physicists in Medicine</rights><rights>2016 American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3215-5a9fde6be1395ddbb9d377e0a0a7138aa6b6412f0aedbe0162809eb7ba59d3163</citedby><cites>FETCH-LOGICAL-c3215-5a9fde6be1395ddbb9d377e0a0a7138aa6b6412f0aedbe0162809eb7ba59d3163</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmp.12075$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmp.12075$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28032904$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bae, Seungbin</creatorcontrib><creatorcontrib>Chun, Jaehee</creatorcontrib><creatorcontrib>Cha, Hyemi</creatorcontrib><creatorcontrib>Yeom, Jung Yeol</creatorcontrib><creatorcontrib>Lee, Kisung</creatorcontrib><creatorcontrib>Lee, Hakjae</creatorcontrib><title>Simulation study of a novel target oriented SPECT design using a variable pinhole collimator</title><title>Medical physics (Lancaster)</title><addtitle>Med Phys</addtitle><description>Purpose In the past decade, demands for organ specific (target oriented) single‐photon emission computed tomography (SPECT) is increasing, and several groups have conducted studies on developing clinical dedicated SPECT with pinhole collimator to improve the spatial resolution. However, acceptance angle of the collimator cannot be adjusted to fit the different ROIs of target objects because the shape of pinhole could not be changed, and the magnifying factor cannot be maximized as the collimator‐to‐detector distance is fixed. Furthermore, those dedicated pinhole SPECTs are typically made for a single purpose and therefore possess a drawback in that it cannot be utilized for any other purpose. In this study, we propose a novel SPECT system using variable pinhole collimator (VP SPECT) whose parameters are flexible. Methods The proposed variable pinhole collimator is modeled on conventional pinhole by piling several tungsten layers of different apertures. Depending on the combination of the holes in each layer, a variety of hole diameters and acceptance angles of the pinhole can be made. In addition, VP SPECT system allows attaching the collimator to the object as close as possible to maximize the sensitivity and adjust the distance of the pinhole from the scintillation detector to optimize the system resolution for each rotation angle, automatically. For quantitative measurement, we compared the sensitivity and spatial resolution of VP SPECT with those of conventional pinhole SPECT. To determine the possibility of the clinical and preclinical use of proposed system, a digital mouse whole‐body (MOBY) phantom is used for simulating the live mouse model. Results The result of simulation using ultra‐micro hot spot phantom shows that the sensitivity of the proposed VP SPECT system is about 297% of that of the conventional system. While hot rods of diameter 0.6 mm can be distinguished in the image with the proposed VP SPECT system, 1.2‐mm hot rods are barely discernible in the conventional pinhole SPECT image. According to the result of MOBY phantom simulation, heart walls separated by 3 mm were not distinguished in conventional pinhole SPECT images, but were clearly discerned in VP SPECT images. Conclusions In this study, we designed a novel pinhole collimator for SPECT and presented preliminary results of target oriented imaging with a simulation study. Currently, we are pursuing strategies to realize the proposed system, with the goal to apply the technology into a high‐sensitivity and high‐resolution preclinical SPECT. Should VP SPECT be applied to the clinical setting, we anticipate a high‐sensitivity, high‐resolution system for applications such as heart dedicated SPECT or related fields.</description><subject>Animals</subject><subject>Computer Simulation</subject><subject>Equipment Design</subject><subject>Feasibility Studies</subject><subject>Heart - diagnostic imaging</subject><subject>Mice</subject><subject>Models, Anatomic</subject><subject>Phantoms, Imaging</subject><subject>pinhole collimator</subject><subject>simulation</subject><subject>single‐photon emission computed tomography</subject><subject>Tomography, Emission-Computed, Single-Photon - instrumentation</subject><subject>Tomography, Emission-Computed, Single-Photon - methods</subject><subject>Tungsten</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kF1LwzAYRoMobk7BXyC59KbzTdq066WM-QETB5t3QkmWtzOSNjVpJ_v3VufHlVfPzeHwcAg5ZzBmAPyqasaMQyYOyJAnWRwlHPJDMgTIk4gnIAbkJIRXAEhjAcdkwCcQ8xySIXlemqqzsjWupqHt9I66kkpauy1a2kq_wZY6b7BuUdPlYjZdUY3BbGraBVNvenQrvZHKIm1M_eL6XTtrTSVb50_JUSltwLPvHZGnm9lqehfNH2_vp9fzaB1zJiIh81JjqpDFudBaqVzHWYYgQWYsnkiZqjRhvASJWiGwtL-fo8qUFD3J0nhELvfexru3DkNbVCas0VpZo-tCwSYiYZBxEH_o2rsQPJZF4_uzflcwKD5bFlVTfLXs0Ytva6cq1L_gT7weiPbAu7G4-1dUPCz2wg8oAH0f</recordid><startdate>201702</startdate><enddate>201702</enddate><creator>Bae, Seungbin</creator><creator>Chun, Jaehee</creator><creator>Cha, Hyemi</creator><creator>Yeom, Jung Yeol</creator><creator>Lee, Kisung</creator><creator>Lee, Hakjae</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201702</creationdate><title>Simulation study of a novel target oriented SPECT design using a variable pinhole collimator</title><author>Bae, Seungbin ; Chun, Jaehee ; Cha, Hyemi ; Yeom, Jung Yeol ; Lee, Kisung ; Lee, Hakjae</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3215-5a9fde6be1395ddbb9d377e0a0a7138aa6b6412f0aedbe0162809eb7ba59d3163</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Animals</topic><topic>Computer Simulation</topic><topic>Equipment Design</topic><topic>Feasibility Studies</topic><topic>Heart - diagnostic imaging</topic><topic>Mice</topic><topic>Models, Anatomic</topic><topic>Phantoms, Imaging</topic><topic>pinhole collimator</topic><topic>simulation</topic><topic>single‐photon emission computed tomography</topic><topic>Tomography, Emission-Computed, Single-Photon - instrumentation</topic><topic>Tomography, Emission-Computed, Single-Photon - methods</topic><topic>Tungsten</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bae, Seungbin</creatorcontrib><creatorcontrib>Chun, Jaehee</creatorcontrib><creatorcontrib>Cha, Hyemi</creatorcontrib><creatorcontrib>Yeom, Jung Yeol</creatorcontrib><creatorcontrib>Lee, Kisung</creatorcontrib><creatorcontrib>Lee, Hakjae</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical physics (Lancaster)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bae, Seungbin</au><au>Chun, Jaehee</au><au>Cha, Hyemi</au><au>Yeom, Jung Yeol</au><au>Lee, Kisung</au><au>Lee, Hakjae</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simulation study of a novel target oriented SPECT design using a variable pinhole collimator</atitle><jtitle>Medical physics (Lancaster)</jtitle><addtitle>Med Phys</addtitle><date>2017-02</date><risdate>2017</risdate><volume>44</volume><issue>2</issue><spage>470</spage><epage>478</epage><pages>470-478</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><abstract>Purpose In the past decade, demands for organ specific (target oriented) single‐photon emission computed tomography (SPECT) is increasing, and several groups have conducted studies on developing clinical dedicated SPECT with pinhole collimator to improve the spatial resolution. However, acceptance angle of the collimator cannot be adjusted to fit the different ROIs of target objects because the shape of pinhole could not be changed, and the magnifying factor cannot be maximized as the collimator‐to‐detector distance is fixed. Furthermore, those dedicated pinhole SPECTs are typically made for a single purpose and therefore possess a drawback in that it cannot be utilized for any other purpose. In this study, we propose a novel SPECT system using variable pinhole collimator (VP SPECT) whose parameters are flexible. Methods The proposed variable pinhole collimator is modeled on conventional pinhole by piling several tungsten layers of different apertures. Depending on the combination of the holes in each layer, a variety of hole diameters and acceptance angles of the pinhole can be made. In addition, VP SPECT system allows attaching the collimator to the object as close as possible to maximize the sensitivity and adjust the distance of the pinhole from the scintillation detector to optimize the system resolution for each rotation angle, automatically. For quantitative measurement, we compared the sensitivity and spatial resolution of VP SPECT with those of conventional pinhole SPECT. To determine the possibility of the clinical and preclinical use of proposed system, a digital mouse whole‐body (MOBY) phantom is used for simulating the live mouse model. Results The result of simulation using ultra‐micro hot spot phantom shows that the sensitivity of the proposed VP SPECT system is about 297% of that of the conventional system. While hot rods of diameter 0.6 mm can be distinguished in the image with the proposed VP SPECT system, 1.2‐mm hot rods are barely discernible in the conventional pinhole SPECT image. According to the result of MOBY phantom simulation, heart walls separated by 3 mm were not distinguished in conventional pinhole SPECT images, but were clearly discerned in VP SPECT images. Conclusions In this study, we designed a novel pinhole collimator for SPECT and presented preliminary results of target oriented imaging with a simulation study. Currently, we are pursuing strategies to realize the proposed system, with the goal to apply the technology into a high‐sensitivity and high‐resolution preclinical SPECT. Should VP SPECT be applied to the clinical setting, we anticipate a high‐sensitivity, high‐resolution system for applications such as heart dedicated SPECT or related fields.</abstract><cop>United States</cop><pmid>28032904</pmid><doi>10.1002/mp.12075</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical physics (Lancaster), 2017-02, Vol.44 (2), p.470-478
issn 0094-2405
2473-4209
language eng
recordid cdi_proquest_miscellaneous_1854107205
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Animals
Computer Simulation
Equipment Design
Feasibility Studies
Heart - diagnostic imaging
Mice
Models, Anatomic
Phantoms, Imaging
pinhole collimator
simulation
single‐photon emission computed tomography
Tomography, Emission-Computed, Single-Photon - instrumentation
Tomography, Emission-Computed, Single-Photon - methods
Tungsten
title Simulation study of a novel target oriented SPECT design using a variable pinhole collimator
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-16T09%3A38%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simulation%20study%20of%20a%20novel%20target%20oriented%20SPECT%20design%20using%20a%20variable%20pinhole%20collimator&rft.jtitle=Medical%20physics%20(Lancaster)&rft.au=Bae,%20Seungbin&rft.date=2017-02&rft.volume=44&rft.issue=2&rft.spage=470&rft.epage=478&rft.pages=470-478&rft.issn=0094-2405&rft.eissn=2473-4209&rft_id=info:doi/10.1002/mp.12075&rft_dat=%3Cproquest_cross%3E1854107205%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1854107205&rft_id=info:pmid/28032904&rfr_iscdi=true