Pressure-standardised mammography does not affect visibility, contrast and sharpness of stable lesions

Abstract Introduction A recent technological development allows pressure-standardised mammography by personalizing the compression force to the breast size and firmness. The technique has been shown to reduce pain and compression variability between consecutive exams, but also results in a slightly...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of radiology 2017-01, Vol.86, p.289-295
Hauptverfasser: de Groot, J.E, Hopman, I.G.M, van Lier, M.G.J.T.B, Branderhorst, W, Grimbergen, C.A, den Heeten, G.J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Introduction A recent technological development allows pressure-standardised mammography by personalizing the compression force to the breast size and firmness. The technique has been shown to reduce pain and compression variability between consecutive exams, but also results in a slightly thicker compressed breast during exposure. This raises the question whether visibility, contrast and sharpness of lesions are affected? Methods Four experienced radiologists compared 188 stable lesions and structures including (clusters of) calcifications, (oil) cysts and lymph nodes that were visible in mammograms obtained in 2009 with a pain-tolerance limited 18 daN target force compression protocol, and in 2014/2015 obtained with a 10 kPa (75 mmHg) pressure-standardised compression protocol. Observers were blinded for all DICOM metadata and rated which of the randomly ordered, side by side presented images had better lesion visibility, contrast and sharpness, or whether they saw no difference. They also indicated which overall image they preferred, if any, and whether the non-preferred image was still adequate. Statistical non-inferiority is concluded when the lower limit of the 95% confidence interval of the 4-rater averaged ‘new protocol better’ proportions exceed the non-inferiority limit of 0.463. Results In 2014/2015, the compressions were significantly milder, with on average 17% (mediolateral oblique) to 29% (craniocaudal) lower forces. Breasts remained on average 2.4% (1.4 mm) thicker. Dose was significantly lower (6.5%), which is explained by glandular atrophy. The 95% confidence interval lower limits are 0.479 for visibility, 0.473 for contrast, 0.488 for sharpness and 0.486 for preference, all exceeding the non-inferiority limit. Of the 60 non-preferred mammograms, multiple observers found only five to be inadequate: 4 obtained with the force protocol and 1 with the pressure protocol. Conclusion Pain-reduced mammography with 10 kPa pressure-standardised compression has non-inferior visibility, contrast and sharpness for stable lesions compared to pain-tolerance limited 18 daN target force compression.
ISSN:0720-048X
1872-7727
DOI:10.1016/j.ejrad.2016.11.030