Insight into the da Vinci® Xi – technical notes for single‐docking left‐sided colorectal procedures

Background The adoption of robot‐assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi‐quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The international journal of medical robotics + computer assisted surgery 2017-12, Vol.13 (4), p.n/a
Hauptverfasser: Ngu, James Chi‐Yong, Sim, Sarah, Yusof, Sulaiman, Ng, Chee‐Yung, Wong, Andrew Siang‐Yih
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page n/a
container_issue 4
container_start_page
container_title The international journal of medical robotics + computer assisted surgery
container_volume 13
creator Ngu, James Chi‐Yong
Sim, Sarah
Yusof, Sulaiman
Ng, Chee‐Yung
Wong, Andrew Siang‐Yih
description Background The adoption of robot‐assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi‐quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left‐sided colorectal procedures. Methods Our initial series of left‐sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Results Between March 2015 and April 2016, 54 cases of robot‐assisted laparoscopic left‐sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi‐quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. Conclusions The da Vinci® Xi simplifies the docking procedure and makes single‐docking feasible for multi‐quadrant left‐sided colorectal procedures.
doi_str_mv 10.1002/rcs.1798
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1852781435</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1852781435</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3498-570bd1d8a90d5226bd449ccc13ffb3ab9958c91c0fbc87502c2f24ab95e01c3d3</originalsourceid><addsrcrecordid>eNp1kN9KHDEUh0NRqrUFn0AC3vRmNckkO8llWWwVhIL_2Lswc3JmN-vsxCYziHc-QsH36EP0UXySZuuqIHiVk8N3vnP4EbLL2QFnTBxGSAe8NPoD2eay1CNlxtONl1rxLfIppQVjUsmx_Ei2hGZMl1xsk8VJl_xs3lPf9YH2c6Suole-A__3D516-nj_QHuEeeehamkXeky0CZEm381afLz_7QJc55q22PT5m7xDRyG0ISL0eeQmBkA3REyfyWZTtQm_rN8dcvn96GJyPDr9-eNk8u10BIU0-d6S1Y47XRnmlBDj2klpAIAXTVMXVW2M0mA4sKYGXSomQDRC5r5CxqFwxQ75-uTNq38NmHq79AmwbasOw5As10qUmstCZXT_DboIQ-zydZabko2V4SV7FUIMKUVs7E30yyreWc7sKn-b87er_DO6txYO9RLdC_gceAZGT8Ctb_HuXZE9m5z_F_4Dj1KSsA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1970659170</pqid></control><display><type>article</type><title>Insight into the da Vinci® Xi – technical notes for single‐docking left‐sided colorectal procedures</title><source>Wiley Online Library All Journals</source><creator>Ngu, James Chi‐Yong ; Sim, Sarah ; Yusof, Sulaiman ; Ng, Chee‐Yung ; Wong, Andrew Siang‐Yih</creator><creatorcontrib>Ngu, James Chi‐Yong ; Sim, Sarah ; Yusof, Sulaiman ; Ng, Chee‐Yung ; Wong, Andrew Siang‐Yih</creatorcontrib><description>Background The adoption of robot‐assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi‐quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left‐sided colorectal procedures. Methods Our initial series of left‐sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Results Between March 2015 and April 2016, 54 cases of robot‐assisted laparoscopic left‐sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi‐quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. Conclusions The da Vinci® Xi simplifies the docking procedure and makes single‐docking feasible for multi‐quadrant left‐sided colorectal procedures.</description><identifier>ISSN: 1478-5951</identifier><identifier>EISSN: 1478-596X</identifier><identifier>DOI: 10.1002/rcs.1798</identifier><identifier>PMID: 28008712</identifier><language>eng</language><publisher>England: Wiley Subscription Services, Inc</publisher><subject>colorectal ; Demographics ; Dissection ; Docking ; laparoscopic ; Laparoscopy ; Pelvis ; robotic ; Robotic surgery ; surgery</subject><ispartof>The international journal of medical robotics + computer assisted surgery, 2017-12, Vol.13 (4), p.n/a</ispartof><rights>Copyright © 2016 John Wiley &amp; Sons, Ltd.</rights><rights>Copyright © 2017 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3498-570bd1d8a90d5226bd449ccc13ffb3ab9958c91c0fbc87502c2f24ab95e01c3d3</citedby><cites>FETCH-LOGICAL-c3498-570bd1d8a90d5226bd449ccc13ffb3ab9958c91c0fbc87502c2f24ab95e01c3d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Frcs.1798$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Frcs.1798$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28008712$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ngu, James Chi‐Yong</creatorcontrib><creatorcontrib>Sim, Sarah</creatorcontrib><creatorcontrib>Yusof, Sulaiman</creatorcontrib><creatorcontrib>Ng, Chee‐Yung</creatorcontrib><creatorcontrib>Wong, Andrew Siang‐Yih</creatorcontrib><title>Insight into the da Vinci® Xi – technical notes for single‐docking left‐sided colorectal procedures</title><title>The international journal of medical robotics + computer assisted surgery</title><addtitle>Int J Med Robot</addtitle><description>Background The adoption of robot‐assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi‐quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left‐sided colorectal procedures. Methods Our initial series of left‐sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Results Between March 2015 and April 2016, 54 cases of robot‐assisted laparoscopic left‐sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi‐quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. Conclusions The da Vinci® Xi simplifies the docking procedure and makes single‐docking feasible for multi‐quadrant left‐sided colorectal procedures.</description><subject>colorectal</subject><subject>Demographics</subject><subject>Dissection</subject><subject>Docking</subject><subject>laparoscopic</subject><subject>Laparoscopy</subject><subject>Pelvis</subject><subject>robotic</subject><subject>Robotic surgery</subject><subject>surgery</subject><issn>1478-5951</issn><issn>1478-596X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp1kN9KHDEUh0NRqrUFn0AC3vRmNckkO8llWWwVhIL_2Lswc3JmN-vsxCYziHc-QsH36EP0UXySZuuqIHiVk8N3vnP4EbLL2QFnTBxGSAe8NPoD2eay1CNlxtONl1rxLfIppQVjUsmx_Ei2hGZMl1xsk8VJl_xs3lPf9YH2c6Suole-A__3D516-nj_QHuEeeehamkXeky0CZEm381afLz_7QJc55q22PT5m7xDRyG0ISL0eeQmBkA3REyfyWZTtQm_rN8dcvn96GJyPDr9-eNk8u10BIU0-d6S1Y47XRnmlBDj2klpAIAXTVMXVW2M0mA4sKYGXSomQDRC5r5CxqFwxQ75-uTNq38NmHq79AmwbasOw5As10qUmstCZXT_DboIQ-zydZabko2V4SV7FUIMKUVs7E30yyreWc7sKn-b87er_DO6txYO9RLdC_gceAZGT8Ctb_HuXZE9m5z_F_4Dj1KSsA</recordid><startdate>201712</startdate><enddate>201712</enddate><creator>Ngu, James Chi‐Yong</creator><creator>Sim, Sarah</creator><creator>Yusof, Sulaiman</creator><creator>Ng, Chee‐Yung</creator><creator>Wong, Andrew Siang‐Yih</creator><general>Wiley Subscription Services, Inc</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>JQ2</scope><scope>K9.</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>7X8</scope></search><sort><creationdate>201712</creationdate><title>Insight into the da Vinci® Xi – technical notes for single‐docking left‐sided colorectal procedures</title><author>Ngu, James Chi‐Yong ; Sim, Sarah ; Yusof, Sulaiman ; Ng, Chee‐Yung ; Wong, Andrew Siang‐Yih</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3498-570bd1d8a90d5226bd449ccc13ffb3ab9958c91c0fbc87502c2f24ab95e01c3d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>colorectal</topic><topic>Demographics</topic><topic>Dissection</topic><topic>Docking</topic><topic>laparoscopic</topic><topic>Laparoscopy</topic><topic>Pelvis</topic><topic>robotic</topic><topic>Robotic surgery</topic><topic>surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ngu, James Chi‐Yong</creatorcontrib><creatorcontrib>Sim, Sarah</creatorcontrib><creatorcontrib>Yusof, Sulaiman</creatorcontrib><creatorcontrib>Ng, Chee‐Yung</creatorcontrib><creatorcontrib>Wong, Andrew Siang‐Yih</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>MEDLINE - Academic</collection><jtitle>The international journal of medical robotics + computer assisted surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ngu, James Chi‐Yong</au><au>Sim, Sarah</au><au>Yusof, Sulaiman</au><au>Ng, Chee‐Yung</au><au>Wong, Andrew Siang‐Yih</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Insight into the da Vinci® Xi – technical notes for single‐docking left‐sided colorectal procedures</atitle><jtitle>The international journal of medical robotics + computer assisted surgery</jtitle><addtitle>Int J Med Robot</addtitle><date>2017-12</date><risdate>2017</risdate><volume>13</volume><issue>4</issue><epage>n/a</epage><issn>1478-5951</issn><eissn>1478-596X</eissn><abstract>Background The adoption of robot‐assisted laparoscopic colorectal surgery has been hampered by issues with docking, operative duration, technical difficulties in multi‐quadrant access, and cost. The da Vinci® Xi has been designed to overcome some of these limitations. We describe our experience with the system and offer technical insights to its application in left‐sided colorectal procedures. Methods Our initial series of left‐sided robotic colorectal procedures was evaluated. Patient demographics and operative outcomes were recorded prospectively using a predefined database. Results Between March 2015 and April 2016, 54 cases of robot‐assisted laparoscopic left‐sided colorectal procedures were successfully completed with no cases of conversion. The majority were low anterior resections for colorectal malignancies. Using the da Vinci® Xi Surgical System, multi‐quadrant surgery involving dissection from the splenic flexure to the pelvis was possible without redocking. Conclusions The da Vinci® Xi simplifies the docking procedure and makes single‐docking feasible for multi‐quadrant left‐sided colorectal procedures.</abstract><cop>England</cop><pub>Wiley Subscription Services, Inc</pub><pmid>28008712</pmid><doi>10.1002/rcs.1798</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1478-5951
ispartof The international journal of medical robotics + computer assisted surgery, 2017-12, Vol.13 (4), p.n/a
issn 1478-5951
1478-596X
language eng
recordid cdi_proquest_miscellaneous_1852781435
source Wiley Online Library All Journals
subjects colorectal
Demographics
Dissection
Docking
laparoscopic
Laparoscopy
Pelvis
robotic
Robotic surgery
surgery
title Insight into the da Vinci® Xi – technical notes for single‐docking left‐sided colorectal procedures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T07%3A13%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Insight%20into%20the%20da%20Vinci%C2%AE%20Xi%20%E2%80%93%20technical%20notes%20for%20single%E2%80%90docking%20left%E2%80%90sided%20colorectal%20procedures&rft.jtitle=The%20international%20journal%20of%20medical%20robotics%20+%20computer%20assisted%20surgery&rft.au=Ngu,%20James%20Chi%E2%80%90Yong&rft.date=2017-12&rft.volume=13&rft.issue=4&rft.epage=n/a&rft.issn=1478-5951&rft.eissn=1478-596X&rft_id=info:doi/10.1002/rcs.1798&rft_dat=%3Cproquest_cross%3E1852781435%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1970659170&rft_id=info:pmid/28008712&rfr_iscdi=true