Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans
Ferrous xylenol gel was evaluated as a dosimeter in verifications of treatment plans for treatments of female breast tumors in external-beam radiation therapy. The dosimeter was calibrated in a cubic wax phantom irradiated with 6 and 15MV beams of an Elekta clinical linear accelerator and then used...
Gespeichert in:
Veröffentlicht in: | Applied radiation and isotopes 2017-02, Vol.120, p.126-132 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 132 |
---|---|
container_issue | |
container_start_page | 126 |
container_title | Applied radiation and isotopes |
container_volume | 120 |
creator | Soliman, Yasser S. El Gohary, M.I. Abdel Gawad, M.H. Amin, E.A. Desouky, O.S. |
description | Ferrous xylenol gel was evaluated as a dosimeter in verifications of treatment plans for treatments of female breast tumors in external-beam radiation therapy. The dosimeter was calibrated in a cubic wax phantom irradiated with 6 and 15MV beams of an Elekta clinical linear accelerator and then used for measurements of doses in an anthropomorphic phantom of a female torso, which mimicked female breasts after modified radical mastectomy and breast-conserving surgery. Doses measured with the gel in specific locations in the phantom were compared with values predicted by treatment plans created with the XiO treatment planning system (Elekta / IMPAQ) and with results of measurements with an IBA CC13 ionization chamber in the same locations. Differences between the values measured with the gel and predicted by the treatment planning system or measured with the ionization chamber were within 1.5% in most cases. In an area of as steep dose gradient, the difference reached 2.7%, which was explicable in terms of the finite size of the gel dosimeter. The dose response of the gel is dose rate and energy independent in the ranges used in most clinical linacs. The results have shown that ferrous xylenol gels can be used as dosimeters in quality assurance in radiation therapy.
•Fricke gel dosimetry is suitable for verifications of radiotherapy treatment plans.•Differences between its results and ionization chamber readings or doses predicted by a TPS are within 1.5% in most cases.•The dose response is energy and dose-rate independent. |
doi_str_mv | 10.1016/j.apradiso.2016.12.004 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1852691965</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969804316310569</els_id><sourcerecordid>1852691965</sourcerecordid><originalsourceid>FETCH-LOGICAL-c368t-acec5ea34dafa74f6d91d34d4c2ff21bc3775f0b6e6bed1ea5764d4f2bbeed193</originalsourceid><addsrcrecordid>eNqFkE9PxCAQxYnR6PrnKxiOXlqBtrTcNMZVExMvGo-EwqCs7VKBmuy3l82qV0_wmDfzmB9C55SUlFB-uSrVFJRx0Zcs65KykpB6Dy1o17JCdITsowURXBQdqasjdBzjimRHJ9ghOmKt6Nqa8wV6XQanPwC_wYCNj26EBAGriBVO3g_YrfHnrAaXNvkxzkGtNWBvcXoHvM33-RLUtMEpgEojrBOeBrWOp-jAqiHC2c95gl6Wt88398Xj093DzfVjoSvepUJp0A2oqjbKqra23Ahqsqo1s5bRXldt21jSc-A9GAqqaXmuWtb3kLWoTtDFbu4U_OcMMcnRRQ1D_gP4OUraNYwLKniTrXxn1cHHGMDKKbhRhY2kRG6hypX8hSq3UCVlMiPLjec_GXM_gvlr-6WYDVc7A-RNvxwEGbWDTMq4ADpJ491_Gd9Uc45w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1852691965</pqid></control><display><type>article</type><title>Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Soliman, Yasser S. ; El Gohary, M.I. ; Abdel Gawad, M.H. ; Amin, E.A. ; Desouky, O.S.</creator><creatorcontrib>Soliman, Yasser S. ; El Gohary, M.I. ; Abdel Gawad, M.H. ; Amin, E.A. ; Desouky, O.S.</creatorcontrib><description>Ferrous xylenol gel was evaluated as a dosimeter in verifications of treatment plans for treatments of female breast tumors in external-beam radiation therapy. The dosimeter was calibrated in a cubic wax phantom irradiated with 6 and 15MV beams of an Elekta clinical linear accelerator and then used for measurements of doses in an anthropomorphic phantom of a female torso, which mimicked female breasts after modified radical mastectomy and breast-conserving surgery. Doses measured with the gel in specific locations in the phantom were compared with values predicted by treatment plans created with the XiO treatment planning system (Elekta / IMPAQ) and with results of measurements with an IBA CC13 ionization chamber in the same locations. Differences between the values measured with the gel and predicted by the treatment planning system or measured with the ionization chamber were within 1.5% in most cases. In an area of as steep dose gradient, the difference reached 2.7%, which was explicable in terms of the finite size of the gel dosimeter. The dose response of the gel is dose rate and energy independent in the ranges used in most clinical linacs. The results have shown that ferrous xylenol gels can be used as dosimeters in quality assurance in radiation therapy.
•Fricke gel dosimetry is suitable for verifications of radiotherapy treatment plans.•Differences between its results and ionization chamber readings or doses predicted by a TPS are within 1.5% in most cases.•The dose response is energy and dose-rate independent.</description><identifier>ISSN: 0969-8043</identifier><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2016.12.004</identifier><identifier>PMID: 27987466</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Breast Neoplasms - radiotherapy ; Dosimetry ; Female ; Ferrous Compounds ; Fricke xylenol gel ; Gels ; Humans ; Particle Accelerators ; Phantoms, Imaging ; Quality assurance ; Quality Assurance, Health Care ; Radiation Dosimeters ; Radiotherapy Dosage ; Radiotherapy Planning, Computer-Assisted - standards ; Radiotherapy treatment planning ; Radiotherapy, High-Energy ; Xylenes</subject><ispartof>Applied radiation and isotopes, 2017-02, Vol.120, p.126-132</ispartof><rights>2016 Elsevier Ltd</rights><rights>Copyright © 2016 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c368t-acec5ea34dafa74f6d91d34d4c2ff21bc3775f0b6e6bed1ea5764d4f2bbeed193</citedby><cites>FETCH-LOGICAL-c368t-acec5ea34dafa74f6d91d34d4c2ff21bc3775f0b6e6bed1ea5764d4f2bbeed193</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.apradiso.2016.12.004$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27987466$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Soliman, Yasser S.</creatorcontrib><creatorcontrib>El Gohary, M.I.</creatorcontrib><creatorcontrib>Abdel Gawad, M.H.</creatorcontrib><creatorcontrib>Amin, E.A.</creatorcontrib><creatorcontrib>Desouky, O.S.</creatorcontrib><title>Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>Ferrous xylenol gel was evaluated as a dosimeter in verifications of treatment plans for treatments of female breast tumors in external-beam radiation therapy. The dosimeter was calibrated in a cubic wax phantom irradiated with 6 and 15MV beams of an Elekta clinical linear accelerator and then used for measurements of doses in an anthropomorphic phantom of a female torso, which mimicked female breasts after modified radical mastectomy and breast-conserving surgery. Doses measured with the gel in specific locations in the phantom were compared with values predicted by treatment plans created with the XiO treatment planning system (Elekta / IMPAQ) and with results of measurements with an IBA CC13 ionization chamber in the same locations. Differences between the values measured with the gel and predicted by the treatment planning system or measured with the ionization chamber were within 1.5% in most cases. In an area of as steep dose gradient, the difference reached 2.7%, which was explicable in terms of the finite size of the gel dosimeter. The dose response of the gel is dose rate and energy independent in the ranges used in most clinical linacs. The results have shown that ferrous xylenol gels can be used as dosimeters in quality assurance in radiation therapy.
•Fricke gel dosimetry is suitable for verifications of radiotherapy treatment plans.•Differences between its results and ionization chamber readings or doses predicted by a TPS are within 1.5% in most cases.•The dose response is energy and dose-rate independent.</description><subject>Breast Neoplasms - radiotherapy</subject><subject>Dosimetry</subject><subject>Female</subject><subject>Ferrous Compounds</subject><subject>Fricke xylenol gel</subject><subject>Gels</subject><subject>Humans</subject><subject>Particle Accelerators</subject><subject>Phantoms, Imaging</subject><subject>Quality assurance</subject><subject>Quality Assurance, Health Care</subject><subject>Radiation Dosimeters</subject><subject>Radiotherapy Dosage</subject><subject>Radiotherapy Planning, Computer-Assisted - standards</subject><subject>Radiotherapy treatment planning</subject><subject>Radiotherapy, High-Energy</subject><subject>Xylenes</subject><issn>0969-8043</issn><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE9PxCAQxYnR6PrnKxiOXlqBtrTcNMZVExMvGo-EwqCs7VKBmuy3l82qV0_wmDfzmB9C55SUlFB-uSrVFJRx0Zcs65KykpB6Dy1o17JCdITsowURXBQdqasjdBzjimRHJ9ghOmKt6Nqa8wV6XQanPwC_wYCNj26EBAGriBVO3g_YrfHnrAaXNvkxzkGtNWBvcXoHvM33-RLUtMEpgEojrBOeBrWOp-jAqiHC2c95gl6Wt88398Xj093DzfVjoSvepUJp0A2oqjbKqra23Ahqsqo1s5bRXldt21jSc-A9GAqqaXmuWtb3kLWoTtDFbu4U_OcMMcnRRQ1D_gP4OUraNYwLKniTrXxn1cHHGMDKKbhRhY2kRG6hypX8hSq3UCVlMiPLjec_GXM_gvlr-6WYDVc7A-RNvxwEGbWDTMq4ADpJ491_Gd9Uc45w</recordid><startdate>201702</startdate><enddate>201702</enddate><creator>Soliman, Yasser S.</creator><creator>El Gohary, M.I.</creator><creator>Abdel Gawad, M.H.</creator><creator>Amin, E.A.</creator><creator>Desouky, O.S.</creator><general>Elsevier Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201702</creationdate><title>Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans</title><author>Soliman, Yasser S. ; El Gohary, M.I. ; Abdel Gawad, M.H. ; Amin, E.A. ; Desouky, O.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c368t-acec5ea34dafa74f6d91d34d4c2ff21bc3775f0b6e6bed1ea5764d4f2bbeed193</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Breast Neoplasms - radiotherapy</topic><topic>Dosimetry</topic><topic>Female</topic><topic>Ferrous Compounds</topic><topic>Fricke xylenol gel</topic><topic>Gels</topic><topic>Humans</topic><topic>Particle Accelerators</topic><topic>Phantoms, Imaging</topic><topic>Quality assurance</topic><topic>Quality Assurance, Health Care</topic><topic>Radiation Dosimeters</topic><topic>Radiotherapy Dosage</topic><topic>Radiotherapy Planning, Computer-Assisted - standards</topic><topic>Radiotherapy treatment planning</topic><topic>Radiotherapy, High-Energy</topic><topic>Xylenes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Soliman, Yasser S.</creatorcontrib><creatorcontrib>El Gohary, M.I.</creatorcontrib><creatorcontrib>Abdel Gawad, M.H.</creatorcontrib><creatorcontrib>Amin, E.A.</creatorcontrib><creatorcontrib>Desouky, O.S.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Soliman, Yasser S.</au><au>El Gohary, M.I.</au><au>Abdel Gawad, M.H.</au><au>Amin, E.A.</au><au>Desouky, O.S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2017-02</date><risdate>2017</risdate><volume>120</volume><spage>126</spage><epage>132</epage><pages>126-132</pages><issn>0969-8043</issn><eissn>1872-9800</eissn><abstract>Ferrous xylenol gel was evaluated as a dosimeter in verifications of treatment plans for treatments of female breast tumors in external-beam radiation therapy. The dosimeter was calibrated in a cubic wax phantom irradiated with 6 and 15MV beams of an Elekta clinical linear accelerator and then used for measurements of doses in an anthropomorphic phantom of a female torso, which mimicked female breasts after modified radical mastectomy and breast-conserving surgery. Doses measured with the gel in specific locations in the phantom were compared with values predicted by treatment plans created with the XiO treatment planning system (Elekta / IMPAQ) and with results of measurements with an IBA CC13 ionization chamber in the same locations. Differences between the values measured with the gel and predicted by the treatment planning system or measured with the ionization chamber were within 1.5% in most cases. In an area of as steep dose gradient, the difference reached 2.7%, which was explicable in terms of the finite size of the gel dosimeter. The dose response of the gel is dose rate and energy independent in the ranges used in most clinical linacs. The results have shown that ferrous xylenol gels can be used as dosimeters in quality assurance in radiation therapy.
•Fricke gel dosimetry is suitable for verifications of radiotherapy treatment plans.•Differences between its results and ionization chamber readings or doses predicted by a TPS are within 1.5% in most cases.•The dose response is energy and dose-rate independent.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>27987466</pmid><doi>10.1016/j.apradiso.2016.12.004</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0969-8043 |
ispartof | Applied radiation and isotopes, 2017-02, Vol.120, p.126-132 |
issn | 0969-8043 1872-9800 |
language | eng |
recordid | cdi_proquest_miscellaneous_1852691965 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Breast Neoplasms - radiotherapy Dosimetry Female Ferrous Compounds Fricke xylenol gel Gels Humans Particle Accelerators Phantoms, Imaging Quality assurance Quality Assurance, Health Care Radiation Dosimeters Radiotherapy Dosage Radiotherapy Planning, Computer-Assisted - standards Radiotherapy treatment planning Radiotherapy, High-Energy Xylenes |
title | Fricke gel dosimeter as a tool in quality assurance of the radiotherapy treatment plans |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T19%3A54%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fricke%20gel%20dosimeter%20as%20a%20tool%20in%20quality%20assurance%20of%20the%20radiotherapy%20treatment%20plans&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Soliman,%20Yasser%20S.&rft.date=2017-02&rft.volume=120&rft.spage=126&rft.epage=132&rft.pages=126-132&rft.issn=0969-8043&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2016.12.004&rft_dat=%3Cproquest_cross%3E1852691965%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1852691965&rft_id=info:pmid/27987466&rft_els_id=S0969804316310569&rfr_iscdi=true |