Increasing Axial Resolution of Ultrasonic Imaging With a Joint Sparse Representation Model

The axial resolution of ultrasonic imaging is confined by the temporal width of acoustic pulse generated by the transducer, which has a limited bandwidth. Deconvolution can eliminate this effect and, therefore, improve the resolution. However, most ultrasonic imaging methods perform deconvolution sc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 2016-12, Vol.63 (12), p.2045-2056
Hauptverfasser: Duan, Junbo, Zhong, Hui, Jing, Bowen, Zhang, Siyuan, Wan, Mingxi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2056
container_issue 12
container_start_page 2045
container_title IEEE transactions on ultrasonics, ferroelectrics, and frequency control
container_volume 63
creator Duan, Junbo
Zhong, Hui
Jing, Bowen
Zhang, Siyuan
Wan, Mingxi
description The axial resolution of ultrasonic imaging is confined by the temporal width of acoustic pulse generated by the transducer, which has a limited bandwidth. Deconvolution can eliminate this effect and, therefore, improve the resolution. However, most ultrasonic imaging methods perform deconvolution scan line by scan line, and therefore the information embedded within the neighbor scan lines is unexplored, especially for those materials with layered structures such as blood vessels. In this paper, a joint sparse representation model is proposed to increase the axial resolution of ultrasonic imaging. The proposed model combines the sparse deconvolution along the axial direction with a sparsity-favoring constraint along the lateral direction. Since the constraint explores the information embedded within neighbor scan lines by connecting nearby pixels in the ultrasound image, the axial resolution of the image improves after deconvolution. The results on simulated data showed that the proposed method can increase resolution and discover layered structure. Moreover, the results on real data showed that the proposed method can measure carotid intima-media thickness automatically with good quality (0.56 ± 0.03 versus 0.60 ± 0.06 mm manually).
doi_str_mv 10.1109/TUFFC.2016.2609141
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1845838141</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>7565583</ieee_id><sourcerecordid>1845838141</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-c6c0dc20155c8f624c49aa381b1169cfb46b557828db8a61ba10486508d35bf23</originalsourceid><addsrcrecordid>eNpdkE1Lw0AQhhdRbK3-AQUJePGSurNf3RxLsVqpCNoieAmbzaZuSbN1NwH996Yf9uBpDvO8LzMPQpeA-wA4uZvNx-NRn2AQfSJwAgyOUBc44bFMOD9GXSwljykG3EFnISwxBsYScoo6ZJAApYR30cek0t6oYKtFNPy2qoxeTXBlU1tXRa6I5mXtVXCV1dFkpRYb7N3Wn5GKnpyt6uhtrXwwbWjtTTBVrbbBZ5eb8hydFKoM5mI_e2g-vp-NHuPpy8NkNJzGmnKoYy00znX7BedaFoIwzRKlqIQMQCS6yJjIOB9IIvNMKgGZAsyk4FjmlGcFoT10u-tde_fVmFCnKxu0KUtVGdeEFCTjsu1j0KI3_9Cla3zVXrelKAiJNxTZUdq7ELwp0rW3K-V_UsDpxny6NZ9uzKd7823oel_dZCuTHyJ_qlvgagdYY8xhPeCCt9fRXzZ6hlw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1845316801</pqid></control><display><type>article</type><title>Increasing Axial Resolution of Ultrasonic Imaging With a Joint Sparse Representation Model</title><source>MEDLINE</source><source>IEEE Electronic Library (IEL)</source><creator>Duan, Junbo ; Zhong, Hui ; Jing, Bowen ; Zhang, Siyuan ; Wan, Mingxi</creator><creatorcontrib>Duan, Junbo ; Zhong, Hui ; Jing, Bowen ; Zhang, Siyuan ; Wan, Mingxi</creatorcontrib><description>The axial resolution of ultrasonic imaging is confined by the temporal width of acoustic pulse generated by the transducer, which has a limited bandwidth. Deconvolution can eliminate this effect and, therefore, improve the resolution. However, most ultrasonic imaging methods perform deconvolution scan line by scan line, and therefore the information embedded within the neighbor scan lines is unexplored, especially for those materials with layered structures such as blood vessels. In this paper, a joint sparse representation model is proposed to increase the axial resolution of ultrasonic imaging. The proposed model combines the sparse deconvolution along the axial direction with a sparsity-favoring constraint along the lateral direction. Since the constraint explores the information embedded within neighbor scan lines by connecting nearby pixels in the ultrasound image, the axial resolution of the image improves after deconvolution. The results on simulated data showed that the proposed method can increase resolution and discover layered structure. Moreover, the results on real data showed that the proposed method can measure carotid intima-media thickness automatically with good quality (0.56 ± 0.03 versus 0.60 ± 0.06 mm manually).</description><identifier>ISSN: 0885-3010</identifier><identifier>EISSN: 1525-8955</identifier><identifier>DOI: 10.1109/TUFFC.2016.2609141</identifier><identifier>PMID: 27913325</identifier><identifier>CODEN: ITUCER</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Acoustics ; Blood vessels ; Carotid Artery, Common - diagnostic imaging ; Carotid Intima-Media Thickness ; Carotid intima–media thickness (IMT) ; Convolution ; Deconvolution ; Humans ; Image Processing, Computer-Assisted - methods ; Image resolution ; Imaging ; Radio frequency ; Representations ; sparse representation modeling ; Transducers ; Ultrasonic imaging</subject><ispartof>IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2016-12, Vol.63 (12), p.2045-2056</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2016</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c351t-c6c0dc20155c8f624c49aa381b1169cfb46b557828db8a61ba10486508d35bf23</citedby><cites>FETCH-LOGICAL-c351t-c6c0dc20155c8f624c49aa381b1169cfb46b557828db8a61ba10486508d35bf23</cites><orcidid>0000-0003-0843-6979 ; 0000-0001-7170-3772 ; 0000-0002-6704-1216 ; 0000-0002-0084-2609 ; 0000-0001-5214-9235</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/7565583$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,792,27901,27902,54733</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27913325$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Duan, Junbo</creatorcontrib><creatorcontrib>Zhong, Hui</creatorcontrib><creatorcontrib>Jing, Bowen</creatorcontrib><creatorcontrib>Zhang, Siyuan</creatorcontrib><creatorcontrib>Wan, Mingxi</creatorcontrib><title>Increasing Axial Resolution of Ultrasonic Imaging With a Joint Sparse Representation Model</title><title>IEEE transactions on ultrasonics, ferroelectrics, and frequency control</title><addtitle>T-UFFC</addtitle><addtitle>IEEE Trans Ultrason Ferroelectr Freq Control</addtitle><description>The axial resolution of ultrasonic imaging is confined by the temporal width of acoustic pulse generated by the transducer, which has a limited bandwidth. Deconvolution can eliminate this effect and, therefore, improve the resolution. However, most ultrasonic imaging methods perform deconvolution scan line by scan line, and therefore the information embedded within the neighbor scan lines is unexplored, especially for those materials with layered structures such as blood vessels. In this paper, a joint sparse representation model is proposed to increase the axial resolution of ultrasonic imaging. The proposed model combines the sparse deconvolution along the axial direction with a sparsity-favoring constraint along the lateral direction. Since the constraint explores the information embedded within neighbor scan lines by connecting nearby pixels in the ultrasound image, the axial resolution of the image improves after deconvolution. The results on simulated data showed that the proposed method can increase resolution and discover layered structure. Moreover, the results on real data showed that the proposed method can measure carotid intima-media thickness automatically with good quality (0.56 ± 0.03 versus 0.60 ± 0.06 mm manually).</description><subject>Acoustics</subject><subject>Blood vessels</subject><subject>Carotid Artery, Common - diagnostic imaging</subject><subject>Carotid Intima-Media Thickness</subject><subject>Carotid intima–media thickness (IMT)</subject><subject>Convolution</subject><subject>Deconvolution</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>Image resolution</subject><subject>Imaging</subject><subject>Radio frequency</subject><subject>Representations</subject><subject>sparse representation modeling</subject><subject>Transducers</subject><subject>Ultrasonic imaging</subject><issn>0885-3010</issn><issn>1525-8955</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>RIE</sourceid><sourceid>EIF</sourceid><recordid>eNpdkE1Lw0AQhhdRbK3-AQUJePGSurNf3RxLsVqpCNoieAmbzaZuSbN1NwH996Yf9uBpDvO8LzMPQpeA-wA4uZvNx-NRn2AQfSJwAgyOUBc44bFMOD9GXSwljykG3EFnISwxBsYScoo6ZJAApYR30cek0t6oYKtFNPy2qoxeTXBlU1tXRa6I5mXtVXCV1dFkpRYb7N3Wn5GKnpyt6uhtrXwwbWjtTTBVrbbBZ5eb8hydFKoM5mI_e2g-vp-NHuPpy8NkNJzGmnKoYy00znX7BedaFoIwzRKlqIQMQCS6yJjIOB9IIvNMKgGZAsyk4FjmlGcFoT10u-tde_fVmFCnKxu0KUtVGdeEFCTjsu1j0KI3_9Cla3zVXrelKAiJNxTZUdq7ELwp0rW3K-V_UsDpxny6NZ9uzKd7823oel_dZCuTHyJ_qlvgagdYY8xhPeCCt9fRXzZ6hlw</recordid><startdate>201612</startdate><enddate>201612</enddate><creator>Duan, Junbo</creator><creator>Zhong, Hui</creator><creator>Jing, Bowen</creator><creator>Zhang, Siyuan</creator><creator>Wan, Mingxi</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0843-6979</orcidid><orcidid>https://orcid.org/0000-0001-7170-3772</orcidid><orcidid>https://orcid.org/0000-0002-6704-1216</orcidid><orcidid>https://orcid.org/0000-0002-0084-2609</orcidid><orcidid>https://orcid.org/0000-0001-5214-9235</orcidid></search><sort><creationdate>201612</creationdate><title>Increasing Axial Resolution of Ultrasonic Imaging With a Joint Sparse Representation Model</title><author>Duan, Junbo ; Zhong, Hui ; Jing, Bowen ; Zhang, Siyuan ; Wan, Mingxi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-c6c0dc20155c8f624c49aa381b1169cfb46b557828db8a61ba10486508d35bf23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Acoustics</topic><topic>Blood vessels</topic><topic>Carotid Artery, Common - diagnostic imaging</topic><topic>Carotid Intima-Media Thickness</topic><topic>Carotid intima–media thickness (IMT)</topic><topic>Convolution</topic><topic>Deconvolution</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>Image resolution</topic><topic>Imaging</topic><topic>Radio frequency</topic><topic>Representations</topic><topic>sparse representation modeling</topic><topic>Transducers</topic><topic>Ultrasonic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Duan, Junbo</creatorcontrib><creatorcontrib>Zhong, Hui</creatorcontrib><creatorcontrib>Jing, Bowen</creatorcontrib><creatorcontrib>Zhang, Siyuan</creatorcontrib><creatorcontrib>Wan, Mingxi</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>IEEE transactions on ultrasonics, ferroelectrics, and frequency control</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Duan, Junbo</au><au>Zhong, Hui</au><au>Jing, Bowen</au><au>Zhang, Siyuan</au><au>Wan, Mingxi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Increasing Axial Resolution of Ultrasonic Imaging With a Joint Sparse Representation Model</atitle><jtitle>IEEE transactions on ultrasonics, ferroelectrics, and frequency control</jtitle><stitle>T-UFFC</stitle><addtitle>IEEE Trans Ultrason Ferroelectr Freq Control</addtitle><date>2016-12</date><risdate>2016</risdate><volume>63</volume><issue>12</issue><spage>2045</spage><epage>2056</epage><pages>2045-2056</pages><issn>0885-3010</issn><eissn>1525-8955</eissn><coden>ITUCER</coden><abstract>The axial resolution of ultrasonic imaging is confined by the temporal width of acoustic pulse generated by the transducer, which has a limited bandwidth. Deconvolution can eliminate this effect and, therefore, improve the resolution. However, most ultrasonic imaging methods perform deconvolution scan line by scan line, and therefore the information embedded within the neighbor scan lines is unexplored, especially for those materials with layered structures such as blood vessels. In this paper, a joint sparse representation model is proposed to increase the axial resolution of ultrasonic imaging. The proposed model combines the sparse deconvolution along the axial direction with a sparsity-favoring constraint along the lateral direction. Since the constraint explores the information embedded within neighbor scan lines by connecting nearby pixels in the ultrasound image, the axial resolution of the image improves after deconvolution. The results on simulated data showed that the proposed method can increase resolution and discover layered structure. Moreover, the results on real data showed that the proposed method can measure carotid intima-media thickness automatically with good quality (0.56 ± 0.03 versus 0.60 ± 0.06 mm manually).</abstract><cop>United States</cop><pub>IEEE</pub><pmid>27913325</pmid><doi>10.1109/TUFFC.2016.2609141</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-0843-6979</orcidid><orcidid>https://orcid.org/0000-0001-7170-3772</orcidid><orcidid>https://orcid.org/0000-0002-6704-1216</orcidid><orcidid>https://orcid.org/0000-0002-0084-2609</orcidid><orcidid>https://orcid.org/0000-0001-5214-9235</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0885-3010
ispartof IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2016-12, Vol.63 (12), p.2045-2056
issn 0885-3010
1525-8955
language eng
recordid cdi_proquest_miscellaneous_1845838141
source MEDLINE; IEEE Electronic Library (IEL)
subjects Acoustics
Blood vessels
Carotid Artery, Common - diagnostic imaging
Carotid Intima-Media Thickness
Carotid intima–media thickness (IMT)
Convolution
Deconvolution
Humans
Image Processing, Computer-Assisted - methods
Image resolution
Imaging
Radio frequency
Representations
sparse representation modeling
Transducers
Ultrasonic imaging
title Increasing Axial Resolution of Ultrasonic Imaging With a Joint Sparse Representation Model
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T03%3A00%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Increasing%20Axial%20Resolution%20of%20Ultrasonic%20Imaging%20With%20a%20Joint%20Sparse%20Representation%20Model&rft.jtitle=IEEE%20transactions%20on%20ultrasonics,%20ferroelectrics,%20and%20frequency%20control&rft.au=Duan,%20Junbo&rft.date=2016-12&rft.volume=63&rft.issue=12&rft.spage=2045&rft.epage=2056&rft.pages=2045-2056&rft.issn=0885-3010&rft.eissn=1525-8955&rft.coden=ITUCER&rft_id=info:doi/10.1109/TUFFC.2016.2609141&rft_dat=%3Cproquest_cross%3E1845838141%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1845316801&rft_id=info:pmid/27913325&rft_ieee_id=7565583&rfr_iscdi=true