High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS

In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a tot...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2017-02, Vol.409 (6), p.1531-1545
Hauptverfasser: Miyashita, Shin-ichi, Mitsuhashi, Hiroaki, Fujii, Shin-ichiro, Takatsu, Akiko, Inagaki, Kazumi, Fujimoto, Toshiyuki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1545
container_issue 6
container_start_page 1531
container_title Analytical and bioanalytical chemistry
container_volume 409
creator Miyashita, Shin-ichi
Mitsuhashi, Hiroaki
Fujii, Shin-ichiro
Takatsu, Akiko
Inagaki, Kazumi
Fujimoto, Toshiyuki
description In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a total-consumption sample introduction system consisting of a large-bore, high-performance concentric nebulizer and a small-volume on-axis cylinder chamber was utilized. Such a system potentially permits a particle TE of 100 %, meaning that there is no need to include a particle TE correction when calculating the PNC and the NP size. When the particle TE through the sample introduction system was evaluated by comparing the frequency of sharp transient signals from the NPs in a measured NP standard of precisely known PNC to the particle frequency for a measured NP suspension, the TE for platinum NPs with a nominal diameter of 70 nm was found to be very high (i.e., 93 %), and showed satisfactory repeatability (relative standard deviation of 1.0 % for four consecutive measurements). These results indicated that employing this total consumption system allows the particle TE correction to be ignored when calculating the PNC. When the particle size was determined using a solution-standard-based calibration approach without an NP standard, the particle diameters of platinum and silver NPs with nominal diameters of 30–100 nm were found to agree well with the particle diameters determined by transmission electron microscopy, regardless of whether a correction was performed for the particle TE. Thus, applying the proposed system enables NP size to be accurately evaluated using a solution-standard-based calibration approach without the need to correct for the particle TE.
doi_str_mv 10.1007/s00216-016-0089-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1845831805</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4317540631</sourcerecordid><originalsourceid>FETCH-LOGICAL-c475t-f1f74a6b85b932caca9fd6629352e562b3aab8e5b46910bffa9b0798d55d8e9a3</originalsourceid><addsrcrecordid>eNp1kcGK1TAUhosozjj6AG4k4MZNNUlv0mYpF3UGRhTUdTlNT-5kSJOapML1xXw9UztzEcHFISHny3dC_qp6zuhrRmn7JlHKmazpWrRTtXhQnTPJuppLQR-e9jt-Vj1J6ZZSJjomH1dnvFWs6Rp2Xv26tIcbkiP4NIeYCRpjtUWvjyQY4sGHGWK22mEi-SaGpdBAcsjgah18WqY52-BJgml2SKzPMYyL3s6OKeNEwI_E5kQG9LjKwRGYZ2c1_KFMiOR-Bkn2JxL8AW7ZmrZYrD84rE_I1f5z_fHL0-qRAZfw2d16UX17_-7r_rK-_vThav_2uta7VuTaMNPuQA6dGFTDNWhQZpSSq0ZwFJIPDcDQoRh2UjE6GANqoK3qRiHGDhU0F9WrzTvH8H3BlPvJJo3OgcewpJ51O1E-sqOioC__QW_DEn15XaFaLhSVDS0U2ygdQ0oRTT9HO0E89oz2a6r9lmpP1yqp9qv5xZ15GSYcTzfuYywA34BUWv6A8a_R_7X-Bps6seI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1872590630</pqid></control><display><type>article</type><title>High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS</title><source>Springer Nature - Complete Springer Journals</source><creator>Miyashita, Shin-ichi ; Mitsuhashi, Hiroaki ; Fujii, Shin-ichiro ; Takatsu, Akiko ; Inagaki, Kazumi ; Fujimoto, Toshiyuki</creator><creatorcontrib>Miyashita, Shin-ichi ; Mitsuhashi, Hiroaki ; Fujii, Shin-ichiro ; Takatsu, Akiko ; Inagaki, Kazumi ; Fujimoto, Toshiyuki</creatorcontrib><description>In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a total-consumption sample introduction system consisting of a large-bore, high-performance concentric nebulizer and a small-volume on-axis cylinder chamber was utilized. Such a system potentially permits a particle TE of 100 %, meaning that there is no need to include a particle TE correction when calculating the PNC and the NP size. When the particle TE through the sample introduction system was evaluated by comparing the frequency of sharp transient signals from the NPs in a measured NP standard of precisely known PNC to the particle frequency for a measured NP suspension, the TE for platinum NPs with a nominal diameter of 70 nm was found to be very high (i.e., 93 %), and showed satisfactory repeatability (relative standard deviation of 1.0 % for four consecutive measurements). These results indicated that employing this total consumption system allows the particle TE correction to be ignored when calculating the PNC. When the particle size was determined using a solution-standard-based calibration approach without an NP standard, the particle diameters of platinum and silver NPs with nominal diameters of 30–100 nm were found to agree well with the particle diameters determined by transmission electron microscopy, regardless of whether a correction was performed for the particle TE. Thus, applying the proposed system enables NP size to be accurately evaluated using a solution-standard-based calibration approach without the need to correct for the particle TE.</description><identifier>ISSN: 1618-2642</identifier><identifier>EISSN: 1618-2650</identifier><identifier>DOI: 10.1007/s00216-016-0089-5</identifier><identifier>PMID: 27913831</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Analytical Chemistry ; Biochemistry ; Calibration ; Characterization and Evaluation of Materials ; Chemistry ; Chemistry and Materials Science ; Efficiency ; Food Science ; Laboratory Medicine ; Monitoring/Environmental Analysis ; Nanoparticles ; Particle size ; Plasma ; Platinum ; Research Paper ; Silver ; Transmission electron microscopy</subject><ispartof>Analytical and bioanalytical chemistry, 2017-02, Vol.409 (6), p.1531-1545</ispartof><rights>Springer-Verlag Berlin Heidelberg 2016</rights><rights>Analytical and Bioanalytical Chemistry is a copyright of Springer, 2017.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c475t-f1f74a6b85b932caca9fd6629352e562b3aab8e5b46910bffa9b0798d55d8e9a3</citedby><cites>FETCH-LOGICAL-c475t-f1f74a6b85b932caca9fd6629352e562b3aab8e5b46910bffa9b0798d55d8e9a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/s00216-016-0089-5$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/s00216-016-0089-5$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27913831$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miyashita, Shin-ichi</creatorcontrib><creatorcontrib>Mitsuhashi, Hiroaki</creatorcontrib><creatorcontrib>Fujii, Shin-ichiro</creatorcontrib><creatorcontrib>Takatsu, Akiko</creatorcontrib><creatorcontrib>Inagaki, Kazumi</creatorcontrib><creatorcontrib>Fujimoto, Toshiyuki</creatorcontrib><title>High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS</title><title>Analytical and bioanalytical chemistry</title><addtitle>Anal Bioanal Chem</addtitle><addtitle>Anal Bioanal Chem</addtitle><description>In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a total-consumption sample introduction system consisting of a large-bore, high-performance concentric nebulizer and a small-volume on-axis cylinder chamber was utilized. Such a system potentially permits a particle TE of 100 %, meaning that there is no need to include a particle TE correction when calculating the PNC and the NP size. When the particle TE through the sample introduction system was evaluated by comparing the frequency of sharp transient signals from the NPs in a measured NP standard of precisely known PNC to the particle frequency for a measured NP suspension, the TE for platinum NPs with a nominal diameter of 70 nm was found to be very high (i.e., 93 %), and showed satisfactory repeatability (relative standard deviation of 1.0 % for four consecutive measurements). These results indicated that employing this total consumption system allows the particle TE correction to be ignored when calculating the PNC. When the particle size was determined using a solution-standard-based calibration approach without an NP standard, the particle diameters of platinum and silver NPs with nominal diameters of 30–100 nm were found to agree well with the particle diameters determined by transmission electron microscopy, regardless of whether a correction was performed for the particle TE. Thus, applying the proposed system enables NP size to be accurately evaluated using a solution-standard-based calibration approach without the need to correct for the particle TE.</description><subject>Analytical Chemistry</subject><subject>Biochemistry</subject><subject>Calibration</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Efficiency</subject><subject>Food Science</subject><subject>Laboratory Medicine</subject><subject>Monitoring/Environmental Analysis</subject><subject>Nanoparticles</subject><subject>Particle size</subject><subject>Plasma</subject><subject>Platinum</subject><subject>Research Paper</subject><subject>Silver</subject><subject>Transmission electron microscopy</subject><issn>1618-2642</issn><issn>1618-2650</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNp1kcGK1TAUhosozjj6AG4k4MZNNUlv0mYpF3UGRhTUdTlNT-5kSJOapML1xXw9UztzEcHFISHny3dC_qp6zuhrRmn7JlHKmazpWrRTtXhQnTPJuppLQR-e9jt-Vj1J6ZZSJjomH1dnvFWs6Rp2Xv26tIcbkiP4NIeYCRpjtUWvjyQY4sGHGWK22mEi-SaGpdBAcsjgah18WqY52-BJgml2SKzPMYyL3s6OKeNEwI_E5kQG9LjKwRGYZ2c1_KFMiOR-Bkn2JxL8AW7ZmrZYrD84rE_I1f5z_fHL0-qRAZfw2d16UX17_-7r_rK-_vThav_2uta7VuTaMNPuQA6dGFTDNWhQZpSSq0ZwFJIPDcDQoRh2UjE6GANqoK3qRiHGDhU0F9WrzTvH8H3BlPvJJo3OgcewpJ51O1E-sqOioC__QW_DEn15XaFaLhSVDS0U2ygdQ0oRTT9HO0E89oz2a6r9lmpP1yqp9qv5xZ15GSYcTzfuYywA34BUWv6A8a_R_7X-Bps6seI</recordid><startdate>20170201</startdate><enddate>20170201</enddate><creator>Miyashita, Shin-ichi</creator><creator>Mitsuhashi, Hiroaki</creator><creator>Fujii, Shin-ichiro</creator><creator>Takatsu, Akiko</creator><creator>Inagaki, Kazumi</creator><creator>Fujimoto, Toshiyuki</creator><general>Springer Berlin Heidelberg</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U7</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AEUYN</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H8D</scope><scope>H8G</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KB.</scope><scope>KR7</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>P64</scope><scope>PDBOC</scope><scope>PHGZM</scope><scope>PHGZT</scope><scope>PJZUB</scope><scope>PKEHL</scope><scope>PPXIY</scope><scope>PQEST</scope><scope>PQGLB</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope></search><sort><creationdate>20170201</creationdate><title>High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS</title><author>Miyashita, Shin-ichi ; Mitsuhashi, Hiroaki ; Fujii, Shin-ichiro ; Takatsu, Akiko ; Inagaki, Kazumi ; Fujimoto, Toshiyuki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c475t-f1f74a6b85b932caca9fd6629352e562b3aab8e5b46910bffa9b0798d55d8e9a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Analytical Chemistry</topic><topic>Biochemistry</topic><topic>Calibration</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Efficiency</topic><topic>Food Science</topic><topic>Laboratory Medicine</topic><topic>Monitoring/Environmental Analysis</topic><topic>Nanoparticles</topic><topic>Particle size</topic><topic>Plasma</topic><topic>Platinum</topic><topic>Research Paper</topic><topic>Silver</topic><topic>Transmission electron microscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miyashita, Shin-ichi</creatorcontrib><creatorcontrib>Mitsuhashi, Hiroaki</creatorcontrib><creatorcontrib>Fujii, Shin-ichiro</creatorcontrib><creatorcontrib>Takatsu, Akiko</creatorcontrib><creatorcontrib>Inagaki, Kazumi</creatorcontrib><creatorcontrib>Fujimoto, Toshiyuki</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest One Sustainability</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>Proquest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Materials Science Collection</collection><collection>ProQuest Central (New)</collection><collection>ProQuest One Academic (New)</collection><collection>ProQuest Health &amp; Medical Research Collection</collection><collection>ProQuest One Academic Middle East (New)</collection><collection>ProQuest One Health &amp; Nursing</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Applied &amp; Life Sciences</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical and bioanalytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miyashita, Shin-ichi</au><au>Mitsuhashi, Hiroaki</au><au>Fujii, Shin-ichiro</au><au>Takatsu, Akiko</au><au>Inagaki, Kazumi</au><au>Fujimoto, Toshiyuki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS</atitle><jtitle>Analytical and bioanalytical chemistry</jtitle><stitle>Anal Bioanal Chem</stitle><addtitle>Anal Bioanal Chem</addtitle><date>2017-02-01</date><risdate>2017</risdate><volume>409</volume><issue>6</issue><spage>1531</spage><epage>1545</epage><pages>1531-1545</pages><issn>1618-2642</issn><eissn>1618-2650</eissn><abstract>In order to facilitate reliable and efficient determination of both the particle number concentration (PNC) and the size of nanoparticles (NPs) by single-particle ICP-MS (spICP-MS) without the need to correct for the particle transport efficiency (TE, a possible source of bias in the results), a total-consumption sample introduction system consisting of a large-bore, high-performance concentric nebulizer and a small-volume on-axis cylinder chamber was utilized. Such a system potentially permits a particle TE of 100 %, meaning that there is no need to include a particle TE correction when calculating the PNC and the NP size. When the particle TE through the sample introduction system was evaluated by comparing the frequency of sharp transient signals from the NPs in a measured NP standard of precisely known PNC to the particle frequency for a measured NP suspension, the TE for platinum NPs with a nominal diameter of 70 nm was found to be very high (i.e., 93 %), and showed satisfactory repeatability (relative standard deviation of 1.0 % for four consecutive measurements). These results indicated that employing this total consumption system allows the particle TE correction to be ignored when calculating the PNC. When the particle size was determined using a solution-standard-based calibration approach without an NP standard, the particle diameters of platinum and silver NPs with nominal diameters of 30–100 nm were found to agree well with the particle diameters determined by transmission electron microscopy, regardless of whether a correction was performed for the particle TE. Thus, applying the proposed system enables NP size to be accurately evaluated using a solution-standard-based calibration approach without the need to correct for the particle TE.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>27913831</pmid><doi>10.1007/s00216-016-0089-5</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1618-2642
ispartof Analytical and bioanalytical chemistry, 2017-02, Vol.409 (6), p.1531-1545
issn 1618-2642
1618-2650
language eng
recordid cdi_proquest_miscellaneous_1845831805
source Springer Nature - Complete Springer Journals
subjects Analytical Chemistry
Biochemistry
Calibration
Characterization and Evaluation of Materials
Chemistry
Chemistry and Materials Science
Efficiency
Food Science
Laboratory Medicine
Monitoring/Environmental Analysis
Nanoparticles
Particle size
Plasma
Platinum
Research Paper
Silver
Transmission electron microscopy
title High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T15%3A14%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20transport%20efficiency%20of%20nanoparticles%20through%20a%20total-consumption%20sample%20introduction%20system%20and%20its%20beneficial%20application%20for%20particle%20size%20evaluation%20in%20single-particle%20ICP-MS&rft.jtitle=Analytical%20and%20bioanalytical%20chemistry&rft.au=Miyashita,%20Shin-ichi&rft.date=2017-02-01&rft.volume=409&rft.issue=6&rft.spage=1531&rft.epage=1545&rft.pages=1531-1545&rft.issn=1618-2642&rft.eissn=1618-2650&rft_id=info:doi/10.1007/s00216-016-0089-5&rft_dat=%3Cproquest_cross%3E4317540631%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1872590630&rft_id=info:pmid/27913831&rfr_iscdi=true