Bilateral Rib-Based Distraction to the Pelvis for the Management of Congenital Gibbus Deformity in the Growing Child With Myelodysplasia

Abstract Background Congenital gibbus deformity of the spine associated with myelodysplasia is a challenging problem in the growing child and is commonly associated with skin breakdown and chronic infection. Surgical solutions including kyphectomy, flap closure of the skin, and early spinal fusion a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spine deformity 2016, Vol.4 (1), p.70-77
1. Verfasser: Smith, John T., MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background Congenital gibbus deformity of the spine associated with myelodysplasia is a challenging problem in the growing child and is commonly associated with skin breakdown and chronic infection. Surgical solutions including kyphectomy, flap closure of the skin, and early spinal fusion are associated with a high rate of complications and, ultimately, a short trunk due to stoppage of spinal growth. The purpose of this article is to describe our early results in using a rib-based distraction to the pelvis without vertebral resection and fusion to manage this deformity. Methods This is an IRB-approved retrospective study of a consecutive single-surgeon series of using the rib-to-pelvis distraction technique in congenital gibbus deformity. There were four patients (two males, two females) with an average age of 20 months (16–25 months). The diagnosis was myelomeningocele (n = 2), congenital kyphosis (n = 1), and congenital kyphoscoliosis (n = 1). All patients were managed with bilateral rib-to-pelvis distraction using the Vertical Expandable Prosthetic Titanium Rib (VEPTR) device. Results The average preoperative gibbus deformity measured 114 degrees (range = 108–154). The average postoperative gibbus measured 52 degrees (range = 36–80). The average length of postoperative follow-up is 66 months (range = 48–84 months). There were 10 complications; a dural leak during device expansion, rib hook migrations and postoperative infections after initial implant that resolved with irrigation, debridement, and intravenous antibiotics. One patient had skin expanders placed preoperatively to facilitate skin coverage. No patient has required vertebral resection to achieve correction of the deformity. No patient has had subsequent skin breakdown over the residual gibbus. Discussion This minimally invasive technique effectively corrects gibbus deformity in the growing child without early vertebral column resection and fusion. Our practice is to intervene early while the gibbus is flexible and prior to skin breakdown over the deformity. These early results are encouraging, but further long-term follow-up is needed to confirm the benefits of this technique over traditional methods. Level of Evidence IV.
ISSN:2212-134X
2212-1358