Assessment of the injection behavior of commercially available bone BSMs for Subchondroplasty registered procedures
Background Bone substitute materials (BSMs) have been commercially available for over 30years and have been used extensively in orthopedic procedures. Some BSMs are described as "injectable." With rising focus on minimally invasive surgical procedures, the range of applications in which th...
Gespeichert in:
Veröffentlicht in: | The knee 2015-12, Vol.22 (6), p.597-603 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Bone substitute materials (BSMs) have been commercially available for over 30years and have been used extensively in orthopedic procedures. Some BSMs are described as "injectable." With rising focus on minimally invasive surgical procedures, the range of applications in which these materials are injectable is of clinical interest. Specifically, their performance in closed, pressurized environments in the trabecular bone with microdamage or abnormal bone remodeling have not been well characterized. This issue arises often in the presence of bone marrow lesions of the subchondral bone in early onset osteoarthritis. The objective was to evaluate the in vitro injectability of several common commercially available BSMs. It was hypothesized that some materials self-described as "injectable" would fail to function in a small microarchitecture in comparison to the large void areas. Methods Mechanical testing was performed and force data was collected. Each sample was additionally radiographed and then imaged under micro-computed tomography (CT). Results Most of the BSM materials failed to be successfully injected into a simulated trabecular model. Simplex(TM), AccuFill registered and StrucSure(TM) materials were the only ones that were injected successfully. Many of the materials underwent phase separation at higher pressures and were not able to be deployed from the injection syringe. In addition, a clinically relevant difference was seen between the manners in which the materials interdigitated into the existing structure. Conclusion The AccuFill registered was the only material able to inject in a closed model and demonstrate adequate implantation of BSM into the simulated trabecular bone. Clinical Relevance Injectability of BSMs is clinically relevant as the interest in minimally invasive surgical procedures is rising rapidly. |
---|---|
ISSN: | 0968-0160 |
DOI: | 10.1016/j.knee.2015.06.017 |