Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy

PURPOSE:Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cornea 2017-01, Vol.36 (1), p.44-47
Hauptverfasser: Eghrari, Allen O, Mumtaz, Aisha A, Garrett, Brian, Rezaei, Mahsa, Akhavan, Mina S, Riazuddin, S Amer, Gottsch, John D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 47
container_issue 1
container_start_page 44
container_title Cornea
container_volume 36
creator Eghrari, Allen O
Mumtaz, Aisha A
Garrett, Brian
Rezaei, Mahsa
Akhavan, Mina S
Riazuddin, S Amer
Gottsch, John D
description PURPOSE:Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. METHODS:Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. RESULTS:A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870–0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797–0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. CONCLUSIONS:Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.
doi_str_mv 10.1097/ICO.0000000000001056
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1836734900</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1836734900</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4026-64856e016cd1e2fbaab2ed124ca3fbe4ea58d1a92621af360b9da77048f409f73</originalsourceid><addsrcrecordid>eNp9kMFO3DAURS1UxEwH_gBVXnYTsB3HTpajoVAkpEEI1pGTPJNQJx78nKL8PUFDUcWCt7mbc--TDiGnnJ1xVujz6832jP13nGXqgCx5lqpE6iL_RpZMaJ2kWrIF-Y74NENaK3FEFkLnnGcqW5JmPUbfmwgNvYMYfOfc2HeDiZ0f6G3ro38MZtdOdD0YN2GH1PpAt9UT1LH7C3SNCIg9DJF6Sy_HukW68WEA4-jFhPPiXD4mh9Y4hJP3XJGHy1_3m9_JzfbqerO-SWrJhEqUzDMFjKu64SBsZUwloOFC1ia1FUgwWd5wUwgluLGpYlXRGK2ZzK1khdXpivzc7-6Cfx4BY9l3WINzZgA_YsnzVOlUFozNqNyjdfCIAWy5C11vwlRyVr75LWe_5We_c-3H-4ex6qH5KP0TOgP5HnjxLkLAP258gVC2s4_Yfr39CvKbiLY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1836734900</pqid></control><display><type>article</type><title>Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Eghrari, Allen O ; Mumtaz, Aisha A ; Garrett, Brian ; Rezaei, Mahsa ; Akhavan, Mina S ; Riazuddin, S Amer ; Gottsch, John D</creator><creatorcontrib>Eghrari, Allen O ; Mumtaz, Aisha A ; Garrett, Brian ; Rezaei, Mahsa ; Akhavan, Mina S ; Riazuddin, S Amer ; Gottsch, John D</creatorcontrib><description>PURPOSE:Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. METHODS:Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. RESULTS:A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870–0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797–0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. CONCLUSIONS:Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.</description><identifier>ISSN: 0277-3740</identifier><identifier>EISSN: 1536-4798</identifier><identifier>DOI: 10.1097/ICO.0000000000001056</identifier><identifier>PMID: 27811565</identifier><language>eng</language><publisher>United States: Copyright Wolters Kluwer Health, Inc. All rights reserved</publisher><subject>Adult ; Case-Control Studies ; Diagnostic Techniques, Ophthalmological ; Endothelium, Corneal - pathology ; Female ; Fuchs' Endothelial Dystrophy - diagnostic imaging ; Humans ; Lighting - methods ; Male ; Photography - methods ; Reproducibility of Results</subject><ispartof>Cornea, 2017-01, Vol.36 (1), p.44-47</ispartof><rights>Copyright © 2017 Wolters Kluwer Health, Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4026-64856e016cd1e2fbaab2ed124ca3fbe4ea58d1a92621af360b9da77048f409f73</citedby><cites>FETCH-LOGICAL-c4026-64856e016cd1e2fbaab2ed124ca3fbe4ea58d1a92621af360b9da77048f409f73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27811565$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Eghrari, Allen O</creatorcontrib><creatorcontrib>Mumtaz, Aisha A</creatorcontrib><creatorcontrib>Garrett, Brian</creatorcontrib><creatorcontrib>Rezaei, Mahsa</creatorcontrib><creatorcontrib>Akhavan, Mina S</creatorcontrib><creatorcontrib>Riazuddin, S Amer</creatorcontrib><creatorcontrib>Gottsch, John D</creatorcontrib><title>Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy</title><title>Cornea</title><addtitle>Cornea</addtitle><description>PURPOSE:Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. METHODS:Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. RESULTS:A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870–0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797–0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. CONCLUSIONS:Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.</description><subject>Adult</subject><subject>Case-Control Studies</subject><subject>Diagnostic Techniques, Ophthalmological</subject><subject>Endothelium, Corneal - pathology</subject><subject>Female</subject><subject>Fuchs' Endothelial Dystrophy - diagnostic imaging</subject><subject>Humans</subject><subject>Lighting - methods</subject><subject>Male</subject><subject>Photography - methods</subject><subject>Reproducibility of Results</subject><issn>0277-3740</issn><issn>1536-4798</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMFO3DAURS1UxEwH_gBVXnYTsB3HTpajoVAkpEEI1pGTPJNQJx78nKL8PUFDUcWCt7mbc--TDiGnnJ1xVujz6832jP13nGXqgCx5lqpE6iL_RpZMaJ2kWrIF-Y74NENaK3FEFkLnnGcqW5JmPUbfmwgNvYMYfOfc2HeDiZ0f6G3ro38MZtdOdD0YN2GH1PpAt9UT1LH7C3SNCIg9DJF6Sy_HukW68WEA4-jFhPPiXD4mh9Y4hJP3XJGHy1_3m9_JzfbqerO-SWrJhEqUzDMFjKu64SBsZUwloOFC1ia1FUgwWd5wUwgluLGpYlXRGK2ZzK1khdXpivzc7-6Cfx4BY9l3WINzZgA_YsnzVOlUFozNqNyjdfCIAWy5C11vwlRyVr75LWe_5We_c-3H-4ex6qH5KP0TOgP5HnjxLkLAP258gVC2s4_Yfr39CvKbiLY</recordid><startdate>201701</startdate><enddate>201701</enddate><creator>Eghrari, Allen O</creator><creator>Mumtaz, Aisha A</creator><creator>Garrett, Brian</creator><creator>Rezaei, Mahsa</creator><creator>Akhavan, Mina S</creator><creator>Riazuddin, S Amer</creator><creator>Gottsch, John D</creator><general>Copyright Wolters Kluwer Health, Inc. All rights reserved</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201701</creationdate><title>Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy</title><author>Eghrari, Allen O ; Mumtaz, Aisha A ; Garrett, Brian ; Rezaei, Mahsa ; Akhavan, Mina S ; Riazuddin, S Amer ; Gottsch, John D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4026-64856e016cd1e2fbaab2ed124ca3fbe4ea58d1a92621af360b9da77048f409f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Adult</topic><topic>Case-Control Studies</topic><topic>Diagnostic Techniques, Ophthalmological</topic><topic>Endothelium, Corneal - pathology</topic><topic>Female</topic><topic>Fuchs' Endothelial Dystrophy - diagnostic imaging</topic><topic>Humans</topic><topic>Lighting - methods</topic><topic>Male</topic><topic>Photography - methods</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Eghrari, Allen O</creatorcontrib><creatorcontrib>Mumtaz, Aisha A</creatorcontrib><creatorcontrib>Garrett, Brian</creatorcontrib><creatorcontrib>Rezaei, Mahsa</creatorcontrib><creatorcontrib>Akhavan, Mina S</creatorcontrib><creatorcontrib>Riazuddin, S Amer</creatorcontrib><creatorcontrib>Gottsch, John D</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Cornea</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Eghrari, Allen O</au><au>Mumtaz, Aisha A</au><au>Garrett, Brian</au><au>Rezaei, Mahsa</au><au>Akhavan, Mina S</au><au>Riazuddin, S Amer</au><au>Gottsch, John D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy</atitle><jtitle>Cornea</jtitle><addtitle>Cornea</addtitle><date>2017-01</date><risdate>2017</risdate><volume>36</volume><issue>1</issue><spage>44</spage><epage>47</epage><pages>44-47</pages><issn>0277-3740</issn><eissn>1536-4798</eissn><abstract>PURPOSE:Retroillumination photography analysis is an objective tool for the assessment of the number and distribution of guttae in eyes affected with Fuchs corneal dystrophy (FCD). Current protocols include manual processing of images; here, we assess validity and interrater reliability of automated analysis across various levels of FCD severity. METHODS:Retroillumination photographs of 97 FCD-affected corneas were acquired, and total counts of guttae were previously summated manually. For each cornea, a single image was loaded into ImageJ software. We reduced color variability and subtracted background noise. Reflection of light from each gutta was identified as a local area of maximum intensity and counted automatically. Noise tolerance level was titrated for each cornea by examining a small region of each image with automated overlay to ensure appropriate coverage of individual guttae. We tested interrater reliability of automated counts of guttae across a spectrum of clinical and educational experience. RESULTS:A set of 97 retroillumination photographs was analyzed. Clinical severity as measured by a modified Krachmer scale ranged from a severity level of 1 to 5 in the set of analyzed corneas. Automated counts by an ophthalmologist correlated strongly with Krachmer grading (R = 0.79) and manual counts (R = 0.88). Intraclass correlation coefficients demonstrated strong correlation at 0.924 (95% CI, 0.870–0.958) among cases analyzed by 3 students, and 0.869 (95% CI, 0.797–0.918) among cases for which images were analyzed by an ophthalmologist and 2 students. CONCLUSIONS:Automated retroillumination photography analysis allows for grading of FCD severity with high resolution across a spectrum of disease severity.</abstract><cop>United States</cop><pub>Copyright Wolters Kluwer Health, Inc. All rights reserved</pub><pmid>27811565</pmid><doi>10.1097/ICO.0000000000001056</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0277-3740
ispartof Cornea, 2017-01, Vol.36 (1), p.44-47
issn 0277-3740
1536-4798
language eng
recordid cdi_proquest_miscellaneous_1836734900
source MEDLINE; Journals@Ovid Complete
subjects Adult
Case-Control Studies
Diagnostic Techniques, Ophthalmological
Endothelium, Corneal - pathology
Female
Fuchs' Endothelial Dystrophy - diagnostic imaging
Humans
Lighting - methods
Male
Photography - methods
Reproducibility of Results
title Automated Retroillumination Photography Analysis for Objective Assessment of Fuchs Corneal Dystrophy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T19%3A45%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automated%20Retroillumination%20Photography%20Analysis%20for%20Objective%20Assessment%20of%20Fuchs%20Corneal%20Dystrophy&rft.jtitle=Cornea&rft.au=Eghrari,%20Allen%20O&rft.date=2017-01&rft.volume=36&rft.issue=1&rft.spage=44&rft.epage=47&rft.pages=44-47&rft.issn=0277-3740&rft.eissn=1536-4798&rft_id=info:doi/10.1097/ICO.0000000000001056&rft_dat=%3Cproquest_cross%3E1836734900%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1836734900&rft_id=info:pmid/27811565&rfr_iscdi=true