Direct chemical inspection of eye shadow and lipstick solid samples using laser-induced breakdown spectroscopy (LIBS) and chemometrics: proposition of classification models

This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples. The analytical procedure was developed by combining emission spectral information obtained by laser-induced breakdo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical methods 2016-01, Vol.8 (29), p.5851-586
Hauptverfasser: Augusto, Amanda dos Santos, Batista, Érica Ferreira, Pereira-Filho, Edenir Rodrigues
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 586
container_issue 29
container_start_page 5851
container_title Analytical methods
container_volume 8
creator Augusto, Amanda dos Santos
Batista, Érica Ferreira
Pereira-Filho, Edenir Rodrigues
description This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples. The analytical procedure was developed by combining emission spectral information obtained by laser-induced breakdown spectroscopy (LIBS) and reference concentration values from inductively coupled plasma optical emission spectrometry (ICP OES). Chemometric tools, such as principal component analysis (PCA), soft independent modelling of class analogies (SIMCA), K-nearest neighbor and partial least squares for discriminant analysis (PLS-DA), were used to perform exploratory analyses (PCA) and to calculate classification models (KNN, SIMCA and PLS-DA). Through this study, it was possible to classify the samples according to the values of Cd, Co, Cr and Ni below and above the tolerance levels indicated by several legislations and the literature (an average and consensus value of 5 mg kg −1 was used). A total of 46 samples intended to be used by adults and children from three different countries were inspected by LIBS and analyzed by ICP OES (after acid digestion), and 16 samples had at least one of the elements with a concentration above 5 mg kg −1 . The most informative spectral range was from 186 to 580 nm, and the proposed classification models presented good results with 98% correct predictions for KNN. No chemical differences were observed between the samples intended to be used by adults and children. This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples.
doi_str_mv 10.1039/c6ay01138a
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835639361</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1835639361</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-90b3acae19381cec35555a8e09a0fc1a9518aad5bd0c86a7974aaed13bef21623</originalsourceid><addsrcrecordid>eNpFkU9PGzEQxVcVSOVPL70j-QiVtthx11n3FlIoSJE40B56Wk3Gs2DwrhfPRijfqR-yTkJhLh6Nfn5v7FcUn5X8qqS252hgLZXSNXwoDtS0sqU1U7v31hv5sThkfpTSWG3UQfH3h0-Eo8AH6jxCEL7nIQ987EVsBa1J8AO4-CKgdyL4gUePT4Jj8E4wdEMgFiv2_b0IwJRK37sVkhPLRPCU7_Viq5ciYxzW4nRxc3F3thXbWMaOxuSRv4shxSGy_2-MWY19m1faTrroKPBxsd9CYPr0eh4Vv68uf82vy8Xtz5v5bFGinuixtHKpAYGU1bVCQl3lgpqkBdmiAlupGsBVSyexNjC1028A5JReUjtRZqKPitOdbl7qeUU8Np1npBCgp7jiRtW6MnrzgRn9skMxv5ATtc2QfAdp3SjZbCJp5mb2ZxvJLMMnOzgxvnHvkel_l2WNoA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835639361</pqid></control><display><type>article</type><title>Direct chemical inspection of eye shadow and lipstick solid samples using laser-induced breakdown spectroscopy (LIBS) and chemometrics: proposition of classification models</title><source>Royal Society Of Chemistry Journals</source><source>Alma/SFX Local Collection</source><creator>Augusto, Amanda dos Santos ; Batista, Érica Ferreira ; Pereira-Filho, Edenir Rodrigues</creator><creatorcontrib>Augusto, Amanda dos Santos ; Batista, Érica Ferreira ; Pereira-Filho, Edenir Rodrigues</creatorcontrib><description>This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples. The analytical procedure was developed by combining emission spectral information obtained by laser-induced breakdown spectroscopy (LIBS) and reference concentration values from inductively coupled plasma optical emission spectrometry (ICP OES). Chemometric tools, such as principal component analysis (PCA), soft independent modelling of class analogies (SIMCA), K-nearest neighbor and partial least squares for discriminant analysis (PLS-DA), were used to perform exploratory analyses (PCA) and to calculate classification models (KNN, SIMCA and PLS-DA). Through this study, it was possible to classify the samples according to the values of Cd, Co, Cr and Ni below and above the tolerance levels indicated by several legislations and the literature (an average and consensus value of 5 mg kg −1 was used). A total of 46 samples intended to be used by adults and children from three different countries were inspected by LIBS and analyzed by ICP OES (after acid digestion), and 16 samples had at least one of the elements with a concentration above 5 mg kg −1 . The most informative spectral range was from 186 to 580 nm, and the proposed classification models presented good results with 98% correct predictions for KNN. No chemical differences were observed between the samples intended to be used by adults and children. This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples.</description><identifier>ISSN: 1759-9660</identifier><identifier>EISSN: 1759-9679</identifier><identifier>DOI: 10.1039/c6ay01138a</identifier><language>eng</language><subject>Adults ; Chemometrics ; Classification ; Eyes ; Inductively coupled plasma ; Laser induced breakdown ; Lipstick ; Spectroscopy</subject><ispartof>Analytical methods, 2016-01, Vol.8 (29), p.5851-586</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-90b3acae19381cec35555a8e09a0fc1a9518aad5bd0c86a7974aaed13bef21623</citedby><cites>FETCH-LOGICAL-c323t-90b3acae19381cec35555a8e09a0fc1a9518aad5bd0c86a7974aaed13bef21623</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Augusto, Amanda dos Santos</creatorcontrib><creatorcontrib>Batista, Érica Ferreira</creatorcontrib><creatorcontrib>Pereira-Filho, Edenir Rodrigues</creatorcontrib><title>Direct chemical inspection of eye shadow and lipstick solid samples using laser-induced breakdown spectroscopy (LIBS) and chemometrics: proposition of classification models</title><title>Analytical methods</title><description>This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples. The analytical procedure was developed by combining emission spectral information obtained by laser-induced breakdown spectroscopy (LIBS) and reference concentration values from inductively coupled plasma optical emission spectrometry (ICP OES). Chemometric tools, such as principal component analysis (PCA), soft independent modelling of class analogies (SIMCA), K-nearest neighbor and partial least squares for discriminant analysis (PLS-DA), were used to perform exploratory analyses (PCA) and to calculate classification models (KNN, SIMCA and PLS-DA). Through this study, it was possible to classify the samples according to the values of Cd, Co, Cr and Ni below and above the tolerance levels indicated by several legislations and the literature (an average and consensus value of 5 mg kg −1 was used). A total of 46 samples intended to be used by adults and children from three different countries were inspected by LIBS and analyzed by ICP OES (after acid digestion), and 16 samples had at least one of the elements with a concentration above 5 mg kg −1 . The most informative spectral range was from 186 to 580 nm, and the proposed classification models presented good results with 98% correct predictions for KNN. No chemical differences were observed between the samples intended to be used by adults and children. This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples.</description><subject>Adults</subject><subject>Chemometrics</subject><subject>Classification</subject><subject>Eyes</subject><subject>Inductively coupled plasma</subject><subject>Laser induced breakdown</subject><subject>Lipstick</subject><subject>Spectroscopy</subject><issn>1759-9660</issn><issn>1759-9679</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNpFkU9PGzEQxVcVSOVPL70j-QiVtthx11n3FlIoSJE40B56Wk3Gs2DwrhfPRijfqR-yTkJhLh6Nfn5v7FcUn5X8qqS252hgLZXSNXwoDtS0sqU1U7v31hv5sThkfpTSWG3UQfH3h0-Eo8AH6jxCEL7nIQ987EVsBa1J8AO4-CKgdyL4gUePT4Jj8E4wdEMgFiv2_b0IwJRK37sVkhPLRPCU7_Viq5ciYxzW4nRxc3F3thXbWMaOxuSRv4shxSGy_2-MWY19m1faTrroKPBxsd9CYPr0eh4Vv68uf82vy8Xtz5v5bFGinuixtHKpAYGU1bVCQl3lgpqkBdmiAlupGsBVSyexNjC1028A5JReUjtRZqKPitOdbl7qeUU8Np1npBCgp7jiRtW6MnrzgRn9skMxv5ATtc2QfAdp3SjZbCJp5mb2ZxvJLMMnOzgxvnHvkel_l2WNoA</recordid><startdate>20160101</startdate><enddate>20160101</enddate><creator>Augusto, Amanda dos Santos</creator><creator>Batista, Érica Ferreira</creator><creator>Pereira-Filho, Edenir Rodrigues</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20160101</creationdate><title>Direct chemical inspection of eye shadow and lipstick solid samples using laser-induced breakdown spectroscopy (LIBS) and chemometrics: proposition of classification models</title><author>Augusto, Amanda dos Santos ; Batista, Érica Ferreira ; Pereira-Filho, Edenir Rodrigues</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-90b3acae19381cec35555a8e09a0fc1a9518aad5bd0c86a7974aaed13bef21623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Adults</topic><topic>Chemometrics</topic><topic>Classification</topic><topic>Eyes</topic><topic>Inductively coupled plasma</topic><topic>Laser induced breakdown</topic><topic>Lipstick</topic><topic>Spectroscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Augusto, Amanda dos Santos</creatorcontrib><creatorcontrib>Batista, Érica Ferreira</creatorcontrib><creatorcontrib>Pereira-Filho, Edenir Rodrigues</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Analytical methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Augusto, Amanda dos Santos</au><au>Batista, Érica Ferreira</au><au>Pereira-Filho, Edenir Rodrigues</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct chemical inspection of eye shadow and lipstick solid samples using laser-induced breakdown spectroscopy (LIBS) and chemometrics: proposition of classification models</atitle><jtitle>Analytical methods</jtitle><date>2016-01-01</date><risdate>2016</risdate><volume>8</volume><issue>29</issue><spage>5851</spage><epage>586</epage><pages>5851-586</pages><issn>1759-9660</issn><eissn>1759-9679</eissn><abstract>This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples. The analytical procedure was developed by combining emission spectral information obtained by laser-induced breakdown spectroscopy (LIBS) and reference concentration values from inductively coupled plasma optical emission spectrometry (ICP OES). Chemometric tools, such as principal component analysis (PCA), soft independent modelling of class analogies (SIMCA), K-nearest neighbor and partial least squares for discriminant analysis (PLS-DA), were used to perform exploratory analyses (PCA) and to calculate classification models (KNN, SIMCA and PLS-DA). Through this study, it was possible to classify the samples according to the values of Cd, Co, Cr and Ni below and above the tolerance levels indicated by several legislations and the literature (an average and consensus value of 5 mg kg −1 was used). A total of 46 samples intended to be used by adults and children from three different countries were inspected by LIBS and analyzed by ICP OES (after acid digestion), and 16 samples had at least one of the elements with a concentration above 5 mg kg −1 . The most informative spectral range was from 186 to 580 nm, and the proposed classification models presented good results with 98% correct predictions for KNN. No chemical differences were observed between the samples intended to be used by adults and children. This study proposes classification models focusing on the identification of contaminated (high concentration of Cd, Co, Cr and Ni) and non-contaminated eye shadow and lipstick samples.</abstract><doi>10.1039/c6ay01138a</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1759-9660
ispartof Analytical methods, 2016-01, Vol.8 (29), p.5851-586
issn 1759-9660
1759-9679
language eng
recordid cdi_proquest_miscellaneous_1835639361
source Royal Society Of Chemistry Journals; Alma/SFX Local Collection
subjects Adults
Chemometrics
Classification
Eyes
Inductively coupled plasma
Laser induced breakdown
Lipstick
Spectroscopy
title Direct chemical inspection of eye shadow and lipstick solid samples using laser-induced breakdown spectroscopy (LIBS) and chemometrics: proposition of classification models
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T20%3A36%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct%20chemical%20inspection%20of%20eye%20shadow%20and%20lipstick%20solid%20samples%20using%20laser-induced%20breakdown%20spectroscopy%20(LIBS)%20and%20chemometrics:%20proposition%20of%20classification%20models&rft.jtitle=Analytical%20methods&rft.au=Augusto,%20Amanda%20dos%20Santos&rft.date=2016-01-01&rft.volume=8&rft.issue=29&rft.spage=5851&rft.epage=586&rft.pages=5851-586&rft.issn=1759-9660&rft.eissn=1759-9679&rft_id=info:doi/10.1039/c6ay01138a&rft_dat=%3Cproquest_cross%3E1835639361%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835639361&rft_id=info:pmid/&rfr_iscdi=true