Development of Portable Device for Point-of-Care Testing of Tumor Marker

By combining electrochemical detection technique and electronic technique, a portable device which adopted differential pulse voltammetry (DPV) measurement was developed to meet the needs of high sensitivity and on-site rapid detection of tumor marker. The voltage and current resolution of portable...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Fēnxī huàxué 2016-07, Vol.44 (7), p.1148-1154
Hauptverfasser: FAN, Yan, WANG, Yang, LIU, Jun-Tao, LUO, Jin-Ping, XU, Hui-Ren, XU, Sheng-Wei, CAI, Xin-Xia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1154
container_issue 7
container_start_page 1148
container_title Fēnxī huàxué
container_volume 44
creator FAN, Yan
WANG, Yang
LIU, Jun-Tao
LUO, Jin-Ping
XU, Hui-Ren
XU, Sheng-Wei
CAI, Xin-Xia
description By combining electrochemical detection technique and electronic technique, a portable device which adopted differential pulse voltammetry (DPV) measurement was developed to meet the needs of high sensitivity and on-site rapid detection of tumor marker. The voltage and current resolution of portable device were 0.8 mV and 1 nA, respectively. Combined with home-made microfluidic paper-based analytical device, carcinoembryonic antigen (CEA) was detected by portable device. Experimental results revealed that the DPV peak currents showed good linear relationship with the logarithm of CEA concentration in the range of 1-500 mu g L super(-1). The corresponding correlation coefficient was 0.998 and the limit of detection was 10 ng L super(-1). According to the principle of specific binding of antibody and antigen with electrochemical detection, CEA concentration could be calculated automatically according to the linear equation. The portable device with the features of high sensitivity and low detection limit could be widely used in the point-of-care testing of tumor marker.
doi_str_mv 10.1016/S1872-2040(16)60947-7
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835593098</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1835593098</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-bb447b36bf10c5bd1aec0c952c4dd1bffd4bf4e09c0b692c8fef368fcfd269073</originalsourceid><addsrcrecordid>eNo9kE1LxDAQhnNQcF39CUKP66E6adKkOcr6scKKgus5JOlEqm2zJq3gv7e7K56Ged6XYXgIuaBwRYGK61daySIvgMOCiksBistcHpHZPz4hpyl9ADBZSjkjq1v8xjZsO-yHLPjsJcTB2BaziTcOMx_ixJp-yIPPlyZitsE0NP37rrwZuyl-MvET4xk59qZNeP435-Tt_m6zXOXr54fH5c06d4wXQ24t59IyYT0FV9qaGnTgVFk4XtfUel9z6zmCcmCFKlzl0TNReefrQiiQbE4Wh7vbGL7G6RfdNclh25oew5g0rVhZKgaqmqrloepiSCmi19vYdCb-aAp6Z0vvbemdFj1te1tasl-Or2AS</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835593098</pqid></control><display><type>article</type><title>Development of Portable Device for Point-of-Care Testing of Tumor Marker</title><source>Elsevier ScienceDirect Journals Complete</source><creator>FAN, Yan ; WANG, Yang ; LIU, Jun-Tao ; LUO, Jin-Ping ; XU, Hui-Ren ; XU, Sheng-Wei ; CAI, Xin-Xia</creator><creatorcontrib>FAN, Yan ; WANG, Yang ; LIU, Jun-Tao ; LUO, Jin-Ping ; XU, Hui-Ren ; XU, Sheng-Wei ; CAI, Xin-Xia</creatorcontrib><description>By combining electrochemical detection technique and electronic technique, a portable device which adopted differential pulse voltammetry (DPV) measurement was developed to meet the needs of high sensitivity and on-site rapid detection of tumor marker. The voltage and current resolution of portable device were 0.8 mV and 1 nA, respectively. Combined with home-made microfluidic paper-based analytical device, carcinoembryonic antigen (CEA) was detected by portable device. Experimental results revealed that the DPV peak currents showed good linear relationship with the logarithm of CEA concentration in the range of 1-500 mu g L super(-1). The corresponding correlation coefficient was 0.998 and the limit of detection was 10 ng L super(-1). According to the principle of specific binding of antibody and antigen with electrochemical detection, CEA concentration could be calculated automatically according to the linear equation. The portable device with the features of high sensitivity and low detection limit could be widely used in the point-of-care testing of tumor marker.</description><identifier>ISSN: 1872-2040</identifier><identifier>ISSN: 0253-3820</identifier><identifier>DOI: 10.1016/S1872-2040(16)60947-7</identifier><language>eng</language><subject>Antigens ; Devices ; Electrochemical analysis ; Electronics ; Markers ; Mathematical analysis ; Portable equipment ; Tumors</subject><ispartof>Fēnxī huàxué, 2016-07, Vol.44 (7), p.1148-1154</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c342t-bb447b36bf10c5bd1aec0c952c4dd1bffd4bf4e09c0b692c8fef368fcfd269073</citedby><cites>FETCH-LOGICAL-c342t-bb447b36bf10c5bd1aec0c952c4dd1bffd4bf4e09c0b692c8fef368fcfd269073</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>FAN, Yan</creatorcontrib><creatorcontrib>WANG, Yang</creatorcontrib><creatorcontrib>LIU, Jun-Tao</creatorcontrib><creatorcontrib>LUO, Jin-Ping</creatorcontrib><creatorcontrib>XU, Hui-Ren</creatorcontrib><creatorcontrib>XU, Sheng-Wei</creatorcontrib><creatorcontrib>CAI, Xin-Xia</creatorcontrib><title>Development of Portable Device for Point-of-Care Testing of Tumor Marker</title><title>Fēnxī huàxué</title><description>By combining electrochemical detection technique and electronic technique, a portable device which adopted differential pulse voltammetry (DPV) measurement was developed to meet the needs of high sensitivity and on-site rapid detection of tumor marker. The voltage and current resolution of portable device were 0.8 mV and 1 nA, respectively. Combined with home-made microfluidic paper-based analytical device, carcinoembryonic antigen (CEA) was detected by portable device. Experimental results revealed that the DPV peak currents showed good linear relationship with the logarithm of CEA concentration in the range of 1-500 mu g L super(-1). The corresponding correlation coefficient was 0.998 and the limit of detection was 10 ng L super(-1). According to the principle of specific binding of antibody and antigen with electrochemical detection, CEA concentration could be calculated automatically according to the linear equation. The portable device with the features of high sensitivity and low detection limit could be widely used in the point-of-care testing of tumor marker.</description><subject>Antigens</subject><subject>Devices</subject><subject>Electrochemical analysis</subject><subject>Electronics</subject><subject>Markers</subject><subject>Mathematical analysis</subject><subject>Portable equipment</subject><subject>Tumors</subject><issn>1872-2040</issn><issn>0253-3820</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNo9kE1LxDAQhnNQcF39CUKP66E6adKkOcr6scKKgus5JOlEqm2zJq3gv7e7K56Ged6XYXgIuaBwRYGK61daySIvgMOCiksBistcHpHZPz4hpyl9ADBZSjkjq1v8xjZsO-yHLPjsJcTB2BaziTcOMx_ixJp-yIPPlyZitsE0NP37rrwZuyl-MvET4xk59qZNeP435-Tt_m6zXOXr54fH5c06d4wXQ24t59IyYT0FV9qaGnTgVFk4XtfUel9z6zmCcmCFKlzl0TNReefrQiiQbE4Wh7vbGL7G6RfdNclh25oew5g0rVhZKgaqmqrloepiSCmi19vYdCb-aAp6Z0vvbemdFj1te1tasl-Or2AS</recordid><startdate>201607</startdate><enddate>201607</enddate><creator>FAN, Yan</creator><creator>WANG, Yang</creator><creator>LIU, Jun-Tao</creator><creator>LUO, Jin-Ping</creator><creator>XU, Hui-Ren</creator><creator>XU, Sheng-Wei</creator><creator>CAI, Xin-Xia</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>201607</creationdate><title>Development of Portable Device for Point-of-Care Testing of Tumor Marker</title><author>FAN, Yan ; WANG, Yang ; LIU, Jun-Tao ; LUO, Jin-Ping ; XU, Hui-Ren ; XU, Sheng-Wei ; CAI, Xin-Xia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-bb447b36bf10c5bd1aec0c952c4dd1bffd4bf4e09c0b692c8fef368fcfd269073</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Antigens</topic><topic>Devices</topic><topic>Electrochemical analysis</topic><topic>Electronics</topic><topic>Markers</topic><topic>Mathematical analysis</topic><topic>Portable equipment</topic><topic>Tumors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>FAN, Yan</creatorcontrib><creatorcontrib>WANG, Yang</creatorcontrib><creatorcontrib>LIU, Jun-Tao</creatorcontrib><creatorcontrib>LUO, Jin-Ping</creatorcontrib><creatorcontrib>XU, Hui-Ren</creatorcontrib><creatorcontrib>XU, Sheng-Wei</creatorcontrib><creatorcontrib>CAI, Xin-Xia</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Fēnxī huàxué</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>FAN, Yan</au><au>WANG, Yang</au><au>LIU, Jun-Tao</au><au>LUO, Jin-Ping</au><au>XU, Hui-Ren</au><au>XU, Sheng-Wei</au><au>CAI, Xin-Xia</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of Portable Device for Point-of-Care Testing of Tumor Marker</atitle><jtitle>Fēnxī huàxué</jtitle><date>2016-07</date><risdate>2016</risdate><volume>44</volume><issue>7</issue><spage>1148</spage><epage>1154</epage><pages>1148-1154</pages><issn>1872-2040</issn><issn>0253-3820</issn><abstract>By combining electrochemical detection technique and electronic technique, a portable device which adopted differential pulse voltammetry (DPV) measurement was developed to meet the needs of high sensitivity and on-site rapid detection of tumor marker. The voltage and current resolution of portable device were 0.8 mV and 1 nA, respectively. Combined with home-made microfluidic paper-based analytical device, carcinoembryonic antigen (CEA) was detected by portable device. Experimental results revealed that the DPV peak currents showed good linear relationship with the logarithm of CEA concentration in the range of 1-500 mu g L super(-1). The corresponding correlation coefficient was 0.998 and the limit of detection was 10 ng L super(-1). According to the principle of specific binding of antibody and antigen with electrochemical detection, CEA concentration could be calculated automatically according to the linear equation. The portable device with the features of high sensitivity and low detection limit could be widely used in the point-of-care testing of tumor marker.</abstract><doi>10.1016/S1872-2040(16)60947-7</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1872-2040
ispartof Fēnxī huàxué, 2016-07, Vol.44 (7), p.1148-1154
issn 1872-2040
0253-3820
language eng
recordid cdi_proquest_miscellaneous_1835593098
source Elsevier ScienceDirect Journals Complete
subjects Antigens
Devices
Electrochemical analysis
Electronics
Markers
Mathematical analysis
Portable equipment
Tumors
title Development of Portable Device for Point-of-Care Testing of Tumor Marker
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T07%3A49%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20Portable%20Device%20for%20Point-of-Care%20Testing%20of%20Tumor%20Marker&rft.jtitle=F%C4%93nx%C4%AB%20hu%C3%A0xu%C3%A9&rft.au=FAN,%20Yan&rft.date=2016-07&rft.volume=44&rft.issue=7&rft.spage=1148&rft.epage=1154&rft.pages=1148-1154&rft.issn=1872-2040&rft_id=info:doi/10.1016/S1872-2040(16)60947-7&rft_dat=%3Cproquest_cross%3E1835593098%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835593098&rft_id=info:pmid/&rfr_iscdi=true