Development of TESPEL Configurations for Plasma Diagnostics

A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of pol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Plasma and fusion research 2015-01, Vol.9, p.1202082-1202082
Hauptverfasser: Sudo, Shigeru, Tamura, Naoki, Suzuki, Chihiro, Funaba, Hisamichi, Takagi, Masaru, Satoh, Nakahiro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1202082
container_issue
container_start_page 1202082
container_title Plasma and fusion research
container_volume 9
creator Sudo, Shigeru
Tamura, Naoki
Suzuki, Chihiro
Funaba, Hisamichi
Takagi, Masaru
Satoh, Nakahiro
description A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835577812</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1835577812</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_18355778123</originalsourceid><addsrcrecordid>eNqVyrsOgjAUANDGxER8_ENHFxIKAWocAePgQCI7acgtqWl7sbf4_S7-gNNZzoYlQsosrWQudmxP9Mqy6lKKKmHXFj5gcXHgI0fNh-7Zdw_eoNdmXoOKBj1xjYH3VpFTvDVq9kjRTHRkW60swenngZ1v3dDc0yXgewWKozM0gbXKA640ClmUZV1LkRd_1C_MNjp0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835577812</pqid></control><display><type>article</type><title>Development of TESPEL Configurations for Plasma Diagnostics</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Sudo, Shigeru ; Tamura, Naoki ; Suzuki, Chihiro ; Funaba, Hisamichi ; Takagi, Masaru ; Satoh, Nakahiro</creator><creatorcontrib>Sudo, Shigeru ; Tamura, Naoki ; Suzuki, Chihiro ; Funaba, Hisamichi ; Takagi, Masaru ; Satoh, Nakahiro</creatorcontrib><description>A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.</description><identifier>EISSN: 1880-6821</identifier><language>eng</language><subject>Deuterium ; Flexibility ; Impurities ; Multilayers ; Pellets ; Plasma diagnostics ; Thin walled shells ; Transport</subject><ispartof>Plasma and fusion research, 2015-01, Vol.9, p.1202082-1202082</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Sudo, Shigeru</creatorcontrib><creatorcontrib>Tamura, Naoki</creatorcontrib><creatorcontrib>Suzuki, Chihiro</creatorcontrib><creatorcontrib>Funaba, Hisamichi</creatorcontrib><creatorcontrib>Takagi, Masaru</creatorcontrib><creatorcontrib>Satoh, Nakahiro</creatorcontrib><title>Development of TESPEL Configurations for Plasma Diagnostics</title><title>Plasma and fusion research</title><description>A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.</description><subject>Deuterium</subject><subject>Flexibility</subject><subject>Impurities</subject><subject>Multilayers</subject><subject>Pellets</subject><subject>Plasma diagnostics</subject><subject>Thin walled shells</subject><subject>Transport</subject><issn>1880-6821</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqVyrsOgjAUANDGxER8_ENHFxIKAWocAePgQCI7acgtqWl7sbf4_S7-gNNZzoYlQsosrWQudmxP9Mqy6lKKKmHXFj5gcXHgI0fNh-7Zdw_eoNdmXoOKBj1xjYH3VpFTvDVq9kjRTHRkW60swenngZ1v3dDc0yXgewWKozM0gbXKA640ClmUZV1LkRd_1C_MNjp0</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Sudo, Shigeru</creator><creator>Tamura, Naoki</creator><creator>Suzuki, Chihiro</creator><creator>Funaba, Hisamichi</creator><creator>Takagi, Masaru</creator><creator>Satoh, Nakahiro</creator><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20150101</creationdate><title>Development of TESPEL Configurations for Plasma Diagnostics</title><author>Sudo, Shigeru ; Tamura, Naoki ; Suzuki, Chihiro ; Funaba, Hisamichi ; Takagi, Masaru ; Satoh, Nakahiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_18355778123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Deuterium</topic><topic>Flexibility</topic><topic>Impurities</topic><topic>Multilayers</topic><topic>Pellets</topic><topic>Plasma diagnostics</topic><topic>Thin walled shells</topic><topic>Transport</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sudo, Shigeru</creatorcontrib><creatorcontrib>Tamura, Naoki</creatorcontrib><creatorcontrib>Suzuki, Chihiro</creatorcontrib><creatorcontrib>Funaba, Hisamichi</creatorcontrib><creatorcontrib>Takagi, Masaru</creatorcontrib><creatorcontrib>Satoh, Nakahiro</creatorcontrib><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Plasma and fusion research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sudo, Shigeru</au><au>Tamura, Naoki</au><au>Suzuki, Chihiro</au><au>Funaba, Hisamichi</au><au>Takagi, Masaru</au><au>Satoh, Nakahiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of TESPEL Configurations for Plasma Diagnostics</atitle><jtitle>Plasma and fusion research</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>9</volume><spage>1202082</spage><epage>1202082</epage><pages>1202082-1202082</pages><eissn>1880-6821</eissn><abstract>A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.</abstract></addata></record>
fulltext fulltext
identifier EISSN: 1880-6821
ispartof Plasma and fusion research, 2015-01, Vol.9, p.1202082-1202082
issn 1880-6821
language eng
recordid cdi_proquest_miscellaneous_1835577812
source J-STAGE Free; EZB-FREE-00999 freely available EZB journals
subjects Deuterium
Flexibility
Impurities
Multilayers
Pellets
Plasma diagnostics
Thin walled shells
Transport
title Development of TESPEL Configurations for Plasma Diagnostics
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T04%3A55%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20TESPEL%20Configurations%20for%20Plasma%20Diagnostics&rft.jtitle=Plasma%20and%20fusion%20research&rft.au=Sudo,%20Shigeru&rft.date=2015-01-01&rft.volume=9&rft.spage=1202082&rft.epage=1202082&rft.pages=1202082-1202082&rft.eissn=1880-6821&rft_id=info:doi/&rft_dat=%3Cproquest%3E1835577812%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835577812&rft_id=info:pmid/&rfr_iscdi=true