Development of TESPEL Configurations for Plasma Diagnostics
A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of pol...
Gespeichert in:
Veröffentlicht in: | Plasma and fusion research 2015-01, Vol.9, p.1202082-1202082 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1202082 |
---|---|
container_issue | |
container_start_page | 1202082 |
container_title | Plasma and fusion research |
container_volume | 9 |
creator | Sudo, Shigeru Tamura, Naoki Suzuki, Chihiro Funaba, Hisamichi Takagi, Masaru Satoh, Nakahiro |
description | A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835577812</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1835577812</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_18355778123</originalsourceid><addsrcrecordid>eNqVyrsOgjAUANDGxER8_ENHFxIKAWocAePgQCI7acgtqWl7sbf4_S7-gNNZzoYlQsosrWQudmxP9Mqy6lKKKmHXFj5gcXHgI0fNh-7Zdw_eoNdmXoOKBj1xjYH3VpFTvDVq9kjRTHRkW60swenngZ1v3dDc0yXgewWKozM0gbXKA640ClmUZV1LkRd_1C_MNjp0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835577812</pqid></control><display><type>article</type><title>Development of TESPEL Configurations for Plasma Diagnostics</title><source>J-STAGE Free</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Sudo, Shigeru ; Tamura, Naoki ; Suzuki, Chihiro ; Funaba, Hisamichi ; Takagi, Masaru ; Satoh, Nakahiro</creator><creatorcontrib>Sudo, Shigeru ; Tamura, Naoki ; Suzuki, Chihiro ; Funaba, Hisamichi ; Takagi, Masaru ; Satoh, Nakahiro</creatorcontrib><description>A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.</description><identifier>EISSN: 1880-6821</identifier><language>eng</language><subject>Deuterium ; Flexibility ; Impurities ; Multilayers ; Pellets ; Plasma diagnostics ; Thin walled shells ; Transport</subject><ispartof>Plasma and fusion research, 2015-01, Vol.9, p.1202082-1202082</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids></links><search><creatorcontrib>Sudo, Shigeru</creatorcontrib><creatorcontrib>Tamura, Naoki</creatorcontrib><creatorcontrib>Suzuki, Chihiro</creatorcontrib><creatorcontrib>Funaba, Hisamichi</creatorcontrib><creatorcontrib>Takagi, Masaru</creatorcontrib><creatorcontrib>Satoh, Nakahiro</creatorcontrib><title>Development of TESPEL Configurations for Plasma Diagnostics</title><title>Plasma and fusion research</title><description>A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.</description><subject>Deuterium</subject><subject>Flexibility</subject><subject>Impurities</subject><subject>Multilayers</subject><subject>Pellets</subject><subject>Plasma diagnostics</subject><subject>Thin walled shells</subject><subject>Transport</subject><issn>1880-6821</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqVyrsOgjAUANDGxER8_ENHFxIKAWocAePgQCI7acgtqWl7sbf4_S7-gNNZzoYlQsosrWQudmxP9Mqy6lKKKmHXFj5gcXHgI0fNh-7Zdw_eoNdmXoOKBj1xjYH3VpFTvDVq9kjRTHRkW60swenngZ1v3dDc0yXgewWKozM0gbXKA640ClmUZV1LkRd_1C_MNjp0</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Sudo, Shigeru</creator><creator>Tamura, Naoki</creator><creator>Suzuki, Chihiro</creator><creator>Funaba, Hisamichi</creator><creator>Takagi, Masaru</creator><creator>Satoh, Nakahiro</creator><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20150101</creationdate><title>Development of TESPEL Configurations for Plasma Diagnostics</title><author>Sudo, Shigeru ; Tamura, Naoki ; Suzuki, Chihiro ; Funaba, Hisamichi ; Takagi, Masaru ; Satoh, Nakahiro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_18355778123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Deuterium</topic><topic>Flexibility</topic><topic>Impurities</topic><topic>Multilayers</topic><topic>Pellets</topic><topic>Plasma diagnostics</topic><topic>Thin walled shells</topic><topic>Transport</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sudo, Shigeru</creatorcontrib><creatorcontrib>Tamura, Naoki</creatorcontrib><creatorcontrib>Suzuki, Chihiro</creatorcontrib><creatorcontrib>Funaba, Hisamichi</creatorcontrib><creatorcontrib>Takagi, Masaru</creatorcontrib><creatorcontrib>Satoh, Nakahiro</creatorcontrib><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Plasma and fusion research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sudo, Shigeru</au><au>Tamura, Naoki</au><au>Suzuki, Chihiro</au><au>Funaba, Hisamichi</au><au>Takagi, Masaru</au><au>Satoh, Nakahiro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of TESPEL Configurations for Plasma Diagnostics</atitle><jtitle>Plasma and fusion research</jtitle><date>2015-01-01</date><risdate>2015</risdate><volume>9</volume><spage>1202082</spage><epage>1202082</epage><pages>1202082-1202082</pages><eissn>1880-6821</eissn><abstract>A Tracer-encapsulated Solid Pellet (TESPEL) injection method has been shown to be useful for many fields of plasma diagnostics. In order to provide more flexibility for such plasma diagnostics, we are developing various types of TESPELs. Here we report a new type TESPEL with a thin shell made of poly-dichlorostyrene useful for the impurity transport study. The new multilayer TESPEL configuration is also discussed. This type of TESPEL is not only useful for impurity transport study but also for the neutron observation due to the transient increase of the deuterium in the local position in the plasma for the upcoming LHD D-D experiment.</abstract></addata></record> |
fulltext | fulltext |
identifier | EISSN: 1880-6821 |
ispartof | Plasma and fusion research, 2015-01, Vol.9, p.1202082-1202082 |
issn | 1880-6821 |
language | eng |
recordid | cdi_proquest_miscellaneous_1835577812 |
source | J-STAGE Free; EZB-FREE-00999 freely available EZB journals |
subjects | Deuterium Flexibility Impurities Multilayers Pellets Plasma diagnostics Thin walled shells Transport |
title | Development of TESPEL Configurations for Plasma Diagnostics |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T04%3A55%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20TESPEL%20Configurations%20for%20Plasma%20Diagnostics&rft.jtitle=Plasma%20and%20fusion%20research&rft.au=Sudo,%20Shigeru&rft.date=2015-01-01&rft.volume=9&rft.spage=1202082&rft.epage=1202082&rft.pages=1202082-1202082&rft.eissn=1880-6821&rft_id=info:doi/&rft_dat=%3Cproquest%3E1835577812%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835577812&rft_id=info:pmid/&rfr_iscdi=true |