Hematologic Evaluation of Normal and Anemic Lambs with the Technicon H1 Using EDTA or Heparin as Anticoagulants
: A study was performed to evaluate blood from young lambs using the Technicon H*1 hematology analyzer, with emphasis on RBC parameters, comparison of tripotassium EDTA and heparin, and the effects of storage on heparinized blood. Blood samples from lambs 2 days to 18 weeks of age were analyzed with...
Gespeichert in:
Veröffentlicht in: | Veterinary clinical pathology 2000-01, Vol.29 (2), p.62-68 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 68 |
---|---|
container_issue | 2 |
container_start_page | 62 |
container_title | Veterinary clinical pathology |
container_volume | 29 |
creator | Vatn, Synnøve Framstad, Tore Torsteinbø, Wenche O. |
description | : A study was performed to evaluate blood from young lambs using the Technicon H*1 hematology analyzer, with emphasis on RBC parameters, comparison of tripotassium EDTA and heparin, and the effects of storage on heparinized blood. Blood samples from lambs 2 days to 18 weeks of age were analyzed within 6 hours, revealing a high precision, except for WBC counts in heparinized blood. The HCT values estimated by the H*1 correlated well (r2= .90) with those obtained by the microhematocrit method. Mean hematologic values obtained for heparinized blood differed by up to 4% from values obtained for blood collected into EDTA. WBC counts decreased 8.4% in heparinized blood stored at 4°C for 1 day, but differences observed in RBC counts were ≤ 2%. Problems occurred when analyzing blood from young lambs with low hemoglobin values because the H*1 incorrectly counted microcytes with volumes of < 10 fL as platelets. When the necessary corrections were performed, the H*1 was useful for analyzing RBC parameters in lamb blood collected both into EDTA and into heparin. |
doi_str_mv | 10.1111/j.1939-165X.2000.tb00401.x |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1835491917</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1835491917</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4092-4a666d324017a8e4095718f775d735fc9026c27cfeb162c45c059cfa22bc53743</originalsourceid><addsrcrecordid>eNqVkF1v0zAUhi0EYmXjLyCLK26S-SO2EyQuqq60m6oxUAeIG8txndYliYvtsO7fz1WrcY1vLJ3zPOfYLwDvMcpxOpfbHFe0yjBnP3OCEMpjjVCBcL5_AUbPrZdghIhgGaclOQNvQtgiRFkqvQZnmCCBSlyMgJubTkXXurXVcPpXtYOK1vXQNfDW-U61UPUrOO5Nl_oL1dUBPti4gXFj4NLoTW91oucY3gfbr-H0ajmGzsO52Slve6hCcmNi1HpoVR_DBXjVqDaYt6f7HNx_ni4n82zxZXY9GS8yXaCKZIXinK8oSb8SqjSpxgQuGyHYSlDW6AoRronQjakxJ7pgGrFKN4qQWjMqCnoOPhzn7rz7M5gQZWeDNm16hHFDkLikrKhwhUVCPx5R7V0I3jRy522n_KPESB4Cl1t5SFUeUpWHwOUpcLlP8rvTnqHuzOqfeko4AZ-OwINtzeN_jJbfJ3ecJD87-jZEs3_2lf8tuaCCyR-3M_lr9nVBvt3MpKBPq6qeYA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835491917</pqid></control><display><type>article</type><title>Hematologic Evaluation of Normal and Anemic Lambs with the Technicon H1 Using EDTA or Heparin as Anticoagulants</title><source>Wiley Online Library All Journals</source><creator>Vatn, Synnøve ; Framstad, Tore ; Torsteinbø, Wenche O.</creator><creatorcontrib>Vatn, Synnøve ; Framstad, Tore ; Torsteinbø, Wenche O.</creatorcontrib><description>: A study was performed to evaluate blood from young lambs using the Technicon H*1 hematology analyzer, with emphasis on RBC parameters, comparison of tripotassium EDTA and heparin, and the effects of storage on heparinized blood. Blood samples from lambs 2 days to 18 weeks of age were analyzed within 6 hours, revealing a high precision, except for WBC counts in heparinized blood. The HCT values estimated by the H*1 correlated well (r2= .90) with those obtained by the microhematocrit method. Mean hematologic values obtained for heparinized blood differed by up to 4% from values obtained for blood collected into EDTA. WBC counts decreased 8.4% in heparinized blood stored at 4°C for 1 day, but differences observed in RBC counts were ≤ 2%. Problems occurred when analyzing blood from young lambs with low hemoglobin values because the H*1 incorrectly counted microcytes with volumes of < 10 fL as platelets. When the necessary corrections were performed, the H*1 was useful for analyzing RBC parameters in lamb blood collected both into EDTA and into heparin.</description><identifier>ISSN: 0275-6382</identifier><identifier>EISSN: 1939-165X</identifier><identifier>DOI: 10.1111/j.1939-165X.2000.tb00401.x</identifier><identifier>PMID: 12070814</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Anemia ; EDTA ; hematology ; heparin ; lambs ; ovine ; Technicon H1</subject><ispartof>Veterinary clinical pathology, 2000-01, Vol.29 (2), p.62-68</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4092-4a666d324017a8e4095718f775d735fc9026c27cfeb162c45c059cfa22bc53743</citedby><cites>FETCH-LOGICAL-c4092-4a666d324017a8e4095718f775d735fc9026c27cfeb162c45c059cfa22bc53743</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1111%2Fj.1939-165X.2000.tb00401.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1111%2Fj.1939-165X.2000.tb00401.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12070814$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vatn, Synnøve</creatorcontrib><creatorcontrib>Framstad, Tore</creatorcontrib><creatorcontrib>Torsteinbø, Wenche O.</creatorcontrib><title>Hematologic Evaluation of Normal and Anemic Lambs with the Technicon H1 Using EDTA or Heparin as Anticoagulants</title><title>Veterinary clinical pathology</title><addtitle>Vet Clin Pathol</addtitle><description>: A study was performed to evaluate blood from young lambs using the Technicon H*1 hematology analyzer, with emphasis on RBC parameters, comparison of tripotassium EDTA and heparin, and the effects of storage on heparinized blood. Blood samples from lambs 2 days to 18 weeks of age were analyzed within 6 hours, revealing a high precision, except for WBC counts in heparinized blood. The HCT values estimated by the H*1 correlated well (r2= .90) with those obtained by the microhematocrit method. Mean hematologic values obtained for heparinized blood differed by up to 4% from values obtained for blood collected into EDTA. WBC counts decreased 8.4% in heparinized blood stored at 4°C for 1 day, but differences observed in RBC counts were ≤ 2%. Problems occurred when analyzing blood from young lambs with low hemoglobin values because the H*1 incorrectly counted microcytes with volumes of < 10 fL as platelets. When the necessary corrections were performed, the H*1 was useful for analyzing RBC parameters in lamb blood collected both into EDTA and into heparin.</description><subject>Anemia</subject><subject>EDTA</subject><subject>hematology</subject><subject>heparin</subject><subject>lambs</subject><subject>ovine</subject><subject>Technicon H1</subject><issn>0275-6382</issn><issn>1939-165X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><recordid>eNqVkF1v0zAUhi0EYmXjLyCLK26S-SO2EyQuqq60m6oxUAeIG8txndYliYvtsO7fz1WrcY1vLJ3zPOfYLwDvMcpxOpfbHFe0yjBnP3OCEMpjjVCBcL5_AUbPrZdghIhgGaclOQNvQtgiRFkqvQZnmCCBSlyMgJubTkXXurXVcPpXtYOK1vXQNfDW-U61UPUrOO5Nl_oL1dUBPti4gXFj4NLoTW91oucY3gfbr-H0ajmGzsO52Slve6hCcmNi1HpoVR_DBXjVqDaYt6f7HNx_ni4n82zxZXY9GS8yXaCKZIXinK8oSb8SqjSpxgQuGyHYSlDW6AoRronQjakxJ7pgGrFKN4qQWjMqCnoOPhzn7rz7M5gQZWeDNm16hHFDkLikrKhwhUVCPx5R7V0I3jRy522n_KPESB4Cl1t5SFUeUpWHwOUpcLlP8rvTnqHuzOqfeko4AZ-OwINtzeN_jJbfJ3ecJD87-jZEs3_2lf8tuaCCyR-3M_lr9nVBvt3MpKBPq6qeYA</recordid><startdate>20000101</startdate><enddate>20000101</enddate><creator>Vatn, Synnøve</creator><creator>Framstad, Tore</creator><creator>Torsteinbø, Wenche O.</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20000101</creationdate><title>Hematologic Evaluation of Normal and Anemic Lambs with the Technicon H1 Using EDTA or Heparin as Anticoagulants</title><author>Vatn, Synnøve ; Framstad, Tore ; Torsteinbø, Wenche O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4092-4a666d324017a8e4095718f775d735fc9026c27cfeb162c45c059cfa22bc53743</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Anemia</topic><topic>EDTA</topic><topic>hematology</topic><topic>heparin</topic><topic>lambs</topic><topic>ovine</topic><topic>Technicon H1</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vatn, Synnøve</creatorcontrib><creatorcontrib>Framstad, Tore</creatorcontrib><creatorcontrib>Torsteinbø, Wenche O.</creatorcontrib><collection>Istex</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Veterinary clinical pathology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vatn, Synnøve</au><au>Framstad, Tore</au><au>Torsteinbø, Wenche O.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hematologic Evaluation of Normal and Anemic Lambs with the Technicon H1 Using EDTA or Heparin as Anticoagulants</atitle><jtitle>Veterinary clinical pathology</jtitle><addtitle>Vet Clin Pathol</addtitle><date>2000-01-01</date><risdate>2000</risdate><volume>29</volume><issue>2</issue><spage>62</spage><epage>68</epage><pages>62-68</pages><issn>0275-6382</issn><eissn>1939-165X</eissn><abstract>: A study was performed to evaluate blood from young lambs using the Technicon H*1 hematology analyzer, with emphasis on RBC parameters, comparison of tripotassium EDTA and heparin, and the effects of storage on heparinized blood. Blood samples from lambs 2 days to 18 weeks of age were analyzed within 6 hours, revealing a high precision, except for WBC counts in heparinized blood. The HCT values estimated by the H*1 correlated well (r2= .90) with those obtained by the microhematocrit method. Mean hematologic values obtained for heparinized blood differed by up to 4% from values obtained for blood collected into EDTA. WBC counts decreased 8.4% in heparinized blood stored at 4°C for 1 day, but differences observed in RBC counts were ≤ 2%. Problems occurred when analyzing blood from young lambs with low hemoglobin values because the H*1 incorrectly counted microcytes with volumes of < 10 fL as platelets. When the necessary corrections were performed, the H*1 was useful for analyzing RBC parameters in lamb blood collected both into EDTA and into heparin.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>12070814</pmid><doi>10.1111/j.1939-165X.2000.tb00401.x</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0275-6382 |
ispartof | Veterinary clinical pathology, 2000-01, Vol.29 (2), p.62-68 |
issn | 0275-6382 1939-165X |
language | eng |
recordid | cdi_proquest_miscellaneous_1835491917 |
source | Wiley Online Library All Journals |
subjects | Anemia EDTA hematology heparin lambs ovine Technicon H1 |
title | Hematologic Evaluation of Normal and Anemic Lambs with the Technicon H1 Using EDTA or Heparin as Anticoagulants |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T06%3A59%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hematologic%20Evaluation%20of%20Normal%20and%20Anemic%20Lambs%20with%20the%20Technicon%20H1%20Using%20EDTA%20or%20Heparin%20as%20Anticoagulants&rft.jtitle=Veterinary%20clinical%20pathology&rft.au=Vatn,%20Synn%C3%B8ve&rft.date=2000-01-01&rft.volume=29&rft.issue=2&rft.spage=62&rft.epage=68&rft.pages=62-68&rft.issn=0275-6382&rft.eissn=1939-165X&rft_id=info:doi/10.1111/j.1939-165X.2000.tb00401.x&rft_dat=%3Cproquest_cross%3E1835491917%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835491917&rft_id=info:pmid/12070814&rfr_iscdi=true |