Electrospray ionization mass spectrometric detection of low polar compounds by adding NaAuCl4
Liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) has been widely used for various analyses. However, it is difficult to use LC/ESI/MS for the analysis of low polar compounds, such as polycyclic aromatic hydrocarbons. It is well known that AuCl4− ion decomposes to AuCl3 by...
Gespeichert in:
Veröffentlicht in: | Journal of mass spectrometry. 2016-11, Vol.51 (11), p.1096-1102 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1102 |
---|---|
container_issue | 11 |
container_start_page | 1096 |
container_title | Journal of mass spectrometry. |
container_volume | 51 |
creator | Moriwaki, Hiroshi |
description | Liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) has been widely used for various analyses. However, it is difficult to use LC/ESI/MS for the analysis of low polar compounds, such as polycyclic aromatic hydrocarbons. It is well known that AuCl4− ion decomposes to AuCl3 by heating, and AuCl3 is a strong π‐electrophilic Lewis acid. Low polar compounds (pyrene, benzo[a]pyrene, perylene, benzo[ghi]perylene, dibenzothiophene and p‐dimethoxybenzene) were detected by ESI/MS in the positive ion mode by adding NaAuCl4. The low polar compound interacts with AuCl3 formed at the ESI interface, and undergoes electron transfer to AuCl3. The radical cation of the low polar compound was then detected by MS. In addition, the LC/ESI/MS determination of polycyclic aromatic hydrocarbons by the post‐column addition of NaAuCl4 was studied. © 2016 The Authors Journal of Mass Spectrometry Published by John Wiley & Sons Ltd |
doi_str_mv | 10.1002/jms.3822 |
format | Article |
fullrecord | <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_proquest_miscellaneous_1826741143</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1826741143</sourcerecordid><originalsourceid>FETCH-LOGICAL-g4332-e6c4882d5469b42c54d1443c76c89915dd4390e52273774095d7df1d44c0244c3</originalsourceid><addsrcrecordid>eNpdkF1LHDEUhkNpQbsK_oRAb3ozmu-PS1nsWlnXgrq9KiEmWZntzGSazKDbX2_GlQq9Oe85nIdzXl4ATjA6xQiRs22bT6ki5AM4xEiLSiulPk69FBXHkh2AzzlvEUJaM3EIfl00wQ0p5j7ZHaxjV_-1QxHY2pxh7l-XbRhS7aAPQxmnZdzAJj7BPjY2QRfbPo6dz_BhB633dfcIV_Z8nDfsCHza2CaH4zedgftvF3fzy2p5s_g-P19Wj4xSUgXhmFLEcyb0AyOOM48Zo04Kp7TG3HtGNQqcEEmlZEhzL_0Ge8YcIqXQGfi6v9un-GcMeTBtnV1oGtuFOGaDFRGSYVy-zcCX_9BtHFNX3BWKckqVZLxQ1Z56qpuwM32qW5t2BiMzhWxKyGYK2Vxd3076ztd5CM__eJt-G1E8c_NztTA_FuuVpsu1EfQFFDV_MQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1835338745</pqid></control><display><type>article</type><title>Electrospray ionization mass spectrometric detection of low polar compounds by adding NaAuCl4</title><source>Wiley Online Library All Journals</source><creator>Moriwaki, Hiroshi</creator><creatorcontrib>Moriwaki, Hiroshi</creatorcontrib><description>Liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) has been widely used for various analyses. However, it is difficult to use LC/ESI/MS for the analysis of low polar compounds, such as polycyclic aromatic hydrocarbons. It is well known that AuCl4− ion decomposes to AuCl3 by heating, and AuCl3 is a strong π‐electrophilic Lewis acid. Low polar compounds (pyrene, benzo[a]pyrene, perylene, benzo[ghi]perylene, dibenzothiophene and p‐dimethoxybenzene) were detected by ESI/MS in the positive ion mode by adding NaAuCl4. The low polar compound interacts with AuCl3 formed at the ESI interface, and undergoes electron transfer to AuCl3. The radical cation of the low polar compound was then detected by MS. In addition, the LC/ESI/MS determination of polycyclic aromatic hydrocarbons by the post‐column addition of NaAuCl4 was studied. © 2016 The Authors Journal of Mass Spectrometry Published by John Wiley & Sons Ltd</description><identifier>ISSN: 1076-5174</identifier><identifier>EISSN: 1096-9888</identifier><identifier>DOI: 10.1002/jms.3822</identifier><language>eng</language><publisher>Bognor Regis: Blackwell Publishing Ltd</publisher><subject>electrospray ionization ; Ions ; low polar compounds ; Mass spectrometry ; Polycyclic aromatic hydrocarbons ; post-column addition ; Scientific imaging ; sodium chloroaurate</subject><ispartof>Journal of mass spectrometry., 2016-11, Vol.51 (11), p.1096-1102</ispartof><rights>2016 The Authors Journal of Mass Spectrometry Published by John Wiley & Sons Ltd</rights><rights>Copyright © 2016 John Wiley & Sons, Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjms.3822$$EPDF$$P50$$Gwiley$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjms.3822$$EHTML$$P50$$Gwiley$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids></links><search><creatorcontrib>Moriwaki, Hiroshi</creatorcontrib><title>Electrospray ionization mass spectrometric detection of low polar compounds by adding NaAuCl4</title><title>Journal of mass spectrometry.</title><addtitle>J. Mass Spectrom</addtitle><description>Liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) has been widely used for various analyses. However, it is difficult to use LC/ESI/MS for the analysis of low polar compounds, such as polycyclic aromatic hydrocarbons. It is well known that AuCl4− ion decomposes to AuCl3 by heating, and AuCl3 is a strong π‐electrophilic Lewis acid. Low polar compounds (pyrene, benzo[a]pyrene, perylene, benzo[ghi]perylene, dibenzothiophene and p‐dimethoxybenzene) were detected by ESI/MS in the positive ion mode by adding NaAuCl4. The low polar compound interacts with AuCl3 formed at the ESI interface, and undergoes electron transfer to AuCl3. The radical cation of the low polar compound was then detected by MS. In addition, the LC/ESI/MS determination of polycyclic aromatic hydrocarbons by the post‐column addition of NaAuCl4 was studied. © 2016 The Authors Journal of Mass Spectrometry Published by John Wiley & Sons Ltd</description><subject>electrospray ionization</subject><subject>Ions</subject><subject>low polar compounds</subject><subject>Mass spectrometry</subject><subject>Polycyclic aromatic hydrocarbons</subject><subject>post-column addition</subject><subject>Scientific imaging</subject><subject>sodium chloroaurate</subject><issn>1076-5174</issn><issn>1096-9888</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>24P</sourceid><recordid>eNpdkF1LHDEUhkNpQbsK_oRAb3ozmu-PS1nsWlnXgrq9KiEmWZntzGSazKDbX2_GlQq9Oe85nIdzXl4ATjA6xQiRs22bT6ki5AM4xEiLSiulPk69FBXHkh2AzzlvEUJaM3EIfl00wQ0p5j7ZHaxjV_-1QxHY2pxh7l-XbRhS7aAPQxmnZdzAJj7BPjY2QRfbPo6dz_BhB633dfcIV_Z8nDfsCHza2CaH4zedgftvF3fzy2p5s_g-P19Wj4xSUgXhmFLEcyb0AyOOM48Zo04Kp7TG3HtGNQqcEEmlZEhzL_0Ge8YcIqXQGfi6v9un-GcMeTBtnV1oGtuFOGaDFRGSYVy-zcCX_9BtHFNX3BWKckqVZLxQ1Z56qpuwM32qW5t2BiMzhWxKyGYK2Vxd3076ztd5CM__eJt-G1E8c_NztTA_FuuVpsu1EfQFFDV_MQ</recordid><startdate>201611</startdate><enddate>201611</enddate><creator>Moriwaki, Hiroshi</creator><general>Blackwell Publishing Ltd</general><general>Wiley Subscription Services, Inc</general><scope>BSCLL</scope><scope>24P</scope><scope>7QF</scope><scope>7QO</scope><scope>7QP</scope><scope>7QQ</scope><scope>7QR</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TK</scope><scope>7U5</scope><scope>7U7</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F1W</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H97</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KR7</scope><scope>L.G</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>201611</creationdate><title>Electrospray ionization mass spectrometric detection of low polar compounds by adding NaAuCl4</title><author>Moriwaki, Hiroshi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g4332-e6c4882d5469b42c54d1443c76c89915dd4390e52273774095d7df1d44c0244c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>electrospray ionization</topic><topic>Ions</topic><topic>low polar compounds</topic><topic>Mass spectrometry</topic><topic>Polycyclic aromatic hydrocarbons</topic><topic>post-column addition</topic><topic>Scientific imaging</topic><topic>sodium chloroaurate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Moriwaki, Hiroshi</creatorcontrib><collection>Istex</collection><collection>Wiley Online Library Open Access</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Chemoreception Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Neurosciences Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Civil Engineering Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of mass spectrometry.</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Moriwaki, Hiroshi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrospray ionization mass spectrometric detection of low polar compounds by adding NaAuCl4</atitle><jtitle>Journal of mass spectrometry.</jtitle><addtitle>J. Mass Spectrom</addtitle><date>2016-11</date><risdate>2016</risdate><volume>51</volume><issue>11</issue><spage>1096</spage><epage>1102</epage><pages>1096-1102</pages><issn>1076-5174</issn><eissn>1096-9888</eissn><abstract>Liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) has been widely used for various analyses. However, it is difficult to use LC/ESI/MS for the analysis of low polar compounds, such as polycyclic aromatic hydrocarbons. It is well known that AuCl4− ion decomposes to AuCl3 by heating, and AuCl3 is a strong π‐electrophilic Lewis acid. Low polar compounds (pyrene, benzo[a]pyrene, perylene, benzo[ghi]perylene, dibenzothiophene and p‐dimethoxybenzene) were detected by ESI/MS in the positive ion mode by adding NaAuCl4. The low polar compound interacts with AuCl3 formed at the ESI interface, and undergoes electron transfer to AuCl3. The radical cation of the low polar compound was then detected by MS. In addition, the LC/ESI/MS determination of polycyclic aromatic hydrocarbons by the post‐column addition of NaAuCl4 was studied. © 2016 The Authors Journal of Mass Spectrometry Published by John Wiley & Sons Ltd</abstract><cop>Bognor Regis</cop><pub>Blackwell Publishing Ltd</pub><doi>10.1002/jms.3822</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1076-5174 |
ispartof | Journal of mass spectrometry., 2016-11, Vol.51 (11), p.1096-1102 |
issn | 1076-5174 1096-9888 |
language | eng |
recordid | cdi_proquest_miscellaneous_1826741143 |
source | Wiley Online Library All Journals |
subjects | electrospray ionization Ions low polar compounds Mass spectrometry Polycyclic aromatic hydrocarbons post-column addition Scientific imaging sodium chloroaurate |
title | Electrospray ionization mass spectrometric detection of low polar compounds by adding NaAuCl4 |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T10%3A27%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrospray%20ionization%20mass%20spectrometric%20detection%20of%20low%20polar%20compounds%20by%20adding%20NaAuCl4&rft.jtitle=Journal%20of%20mass%20spectrometry.&rft.au=Moriwaki,%20Hiroshi&rft.date=2016-11&rft.volume=51&rft.issue=11&rft.spage=1096&rft.epage=1102&rft.pages=1096-1102&rft.issn=1076-5174&rft.eissn=1096-9888&rft_id=info:doi/10.1002/jms.3822&rft_dat=%3Cproquest_wiley%3E1826741143%3C/proquest_wiley%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1835338745&rft_id=info:pmid/&rfr_iscdi=true |