Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products

Two sensitive and accurate stability-indicating chromatographic methods were developed and validated for the determination of rafoxanide (RFX). Degradation products were identified by mass spectrometry and IR spectroscopy. The first is ultra-performance liquid chromatography method where separation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatographic science 2016-10, Vol.54 (9), p.1661-1669
Hauptverfasser: Saad, Ahmed S., Hamdy, Abdallah M., Salama, Fathy M., Abdelkawy, Mohamed
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1669
container_issue 9
container_start_page 1661
container_title Journal of chromatographic science
container_volume 54
creator Saad, Ahmed S.
Hamdy, Abdallah M.
Salama, Fathy M.
Abdelkawy, Mohamed
description Two sensitive and accurate stability-indicating chromatographic methods were developed and validated for the determination of rafoxanide (RFX). Degradation products were identified by mass spectrometry and IR spectroscopy. The first is ultra-performance liquid chromatography method where separation was performed using acetonitrile:0.005 M potassium dihydrogen orthophosphate (pH 3.5) in a ratio of 80:20 by volume as a mobile phase using a Hypersil GOLD™ C8 column 1.9 mm (50 × 2.1 mm), UV detection was adjusted at 220 nm and the flow rate was 0.6 mL min−1. The other is a thin-layer chromatography-densitometry method where separation was achieved using a mobile phase composed of chloroform:ethyl acetate:toluene:ammonia (5:4:3:0.1 by volume) on silica gel 60 F254 plates, and densitometric detection was done at 280 nm. Validation was achieved as per the ICH guidelines. The proposed methods proved to be accurate, robust, specific and suitable for application as stability-indicating methods for routine analysis of RFX in quality control laboratories.
doi_str_mv 10.1093/chromsci/bmw112
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1826714578</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/chromsci/bmw112</oup_id><sourcerecordid>1826714578</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-9f8e5b7e0bd36249d55f589986748cc1d2af2c87cb658b7c8788c94442b41d493</originalsourceid><addsrcrecordid>eNqFkUtv1DAUha0KRIeWdXeVlwgpTPxK7GU15THSIEa0Rewix77puErswXYE8y_4yWRI2y2re6_Od87iHoQuSPmelIotzS6GIRm3bIdfhNATtCCKi4Iy9eMFWpQlJYWqKnGKXqf0cDyJFK_QKa1ZJRlnC_Tnu-6d1RksvttuVlh7i283q-IafHI5DJDjAd9k3bre5QNee-uMzs7f4y-Qd8Em3IWI8w7wNWSIg_OTGjwOHf6mu_Bbe2cBO_8P2UZI4A0c1XVOk-U-ajsbtjHY0eR0jl52uk_w5nGeobuPH25Xn4vN10_r1dWmMKxmuVCdBNHWULaWVZQrK0QnpFKyqrk0hliqO2pkbdpKyLaeNimN4pzTlhPLFTtDb-fcfQw_R0i5GVwy0PfaQxhTQyStasJFLSd0OaMmhpQidM0-ukHHQ0PK5lhD81RDM9cwOS4fw8d2APvMP_19At7NQBj3_037CwTTlqI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1826714578</pqid></control><display><type>article</type><title>Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><source>Free Full-Text Journals in Chemistry</source><creator>Saad, Ahmed S. ; Hamdy, Abdallah M. ; Salama, Fathy M. ; Abdelkawy, Mohamed</creator><creatorcontrib>Saad, Ahmed S. ; Hamdy, Abdallah M. ; Salama, Fathy M. ; Abdelkawy, Mohamed</creatorcontrib><description>Two sensitive and accurate stability-indicating chromatographic methods were developed and validated for the determination of rafoxanide (RFX). Degradation products were identified by mass spectrometry and IR spectroscopy. The first is ultra-performance liquid chromatography method where separation was performed using acetonitrile:0.005 M potassium dihydrogen orthophosphate (pH 3.5) in a ratio of 80:20 by volume as a mobile phase using a Hypersil GOLD™ C8 column 1.9 mm (50 × 2.1 mm), UV detection was adjusted at 220 nm and the flow rate was 0.6 mL min−1. The other is a thin-layer chromatography-densitometry method where separation was achieved using a mobile phase composed of chloroform:ethyl acetate:toluene:ammonia (5:4:3:0.1 by volume) on silica gel 60 F254 plates, and densitometric detection was done at 280 nm. Validation was achieved as per the ICH guidelines. The proposed methods proved to be accurate, robust, specific and suitable for application as stability-indicating methods for routine analysis of RFX in quality control laboratories.</description><identifier>ISSN: 0021-9665</identifier><identifier>EISSN: 1945-239X</identifier><identifier>DOI: 10.1093/chromsci/bmw112</identifier><identifier>PMID: 27368343</identifier><language>eng</language><publisher>United States: Oxford University Press</publisher><ispartof>Journal of chromatographic science, 2016-10, Vol.54 (9), p.1661-1669</ispartof><rights>The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com 2016</rights><rights>The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-9f8e5b7e0bd36249d55f589986748cc1d2af2c87cb658b7c8788c94442b41d493</citedby><cites>FETCH-LOGICAL-c373t-9f8e5b7e0bd36249d55f589986748cc1d2af2c87cb658b7c8788c94442b41d493</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1584,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27368343$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Saad, Ahmed S.</creatorcontrib><creatorcontrib>Hamdy, Abdallah M.</creatorcontrib><creatorcontrib>Salama, Fathy M.</creatorcontrib><creatorcontrib>Abdelkawy, Mohamed</creatorcontrib><title>Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products</title><title>Journal of chromatographic science</title><addtitle>J Chromatogr Sci</addtitle><description>Two sensitive and accurate stability-indicating chromatographic methods were developed and validated for the determination of rafoxanide (RFX). Degradation products were identified by mass spectrometry and IR spectroscopy. The first is ultra-performance liquid chromatography method where separation was performed using acetonitrile:0.005 M potassium dihydrogen orthophosphate (pH 3.5) in a ratio of 80:20 by volume as a mobile phase using a Hypersil GOLD™ C8 column 1.9 mm (50 × 2.1 mm), UV detection was adjusted at 220 nm and the flow rate was 0.6 mL min−1. The other is a thin-layer chromatography-densitometry method where separation was achieved using a mobile phase composed of chloroform:ethyl acetate:toluene:ammonia (5:4:3:0.1 by volume) on silica gel 60 F254 plates, and densitometric detection was done at 280 nm. Validation was achieved as per the ICH guidelines. The proposed methods proved to be accurate, robust, specific and suitable for application as stability-indicating methods for routine analysis of RFX in quality control laboratories.</description><issn>0021-9665</issn><issn>1945-239X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNqFkUtv1DAUha0KRIeWdXeVlwgpTPxK7GU15THSIEa0Rewix77puErswXYE8y_4yWRI2y2re6_Od87iHoQuSPmelIotzS6GIRm3bIdfhNATtCCKi4Iy9eMFWpQlJYWqKnGKXqf0cDyJFK_QKa1ZJRlnC_Tnu-6d1RksvttuVlh7i283q-IafHI5DJDjAd9k3bre5QNee-uMzs7f4y-Qd8Em3IWI8w7wNWSIg_OTGjwOHf6mu_Bbe2cBO_8P2UZI4A0c1XVOk-U-ajsbtjHY0eR0jl52uk_w5nGeobuPH25Xn4vN10_r1dWmMKxmuVCdBNHWULaWVZQrK0QnpFKyqrk0hliqO2pkbdpKyLaeNimN4pzTlhPLFTtDb-fcfQw_R0i5GVwy0PfaQxhTQyStasJFLSd0OaMmhpQidM0-ukHHQ0PK5lhD81RDM9cwOS4fw8d2APvMP_19At7NQBj3_037CwTTlqI</recordid><startdate>20161001</startdate><enddate>20161001</enddate><creator>Saad, Ahmed S.</creator><creator>Hamdy, Abdallah M.</creator><creator>Salama, Fathy M.</creator><creator>Abdelkawy, Mohamed</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20161001</creationdate><title>Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products</title><author>Saad, Ahmed S. ; Hamdy, Abdallah M. ; Salama, Fathy M. ; Abdelkawy, Mohamed</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-9f8e5b7e0bd36249d55f589986748cc1d2af2c87cb658b7c8788c94442b41d493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saad, Ahmed S.</creatorcontrib><creatorcontrib>Hamdy, Abdallah M.</creatorcontrib><creatorcontrib>Salama, Fathy M.</creatorcontrib><creatorcontrib>Abdelkawy, Mohamed</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatographic science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saad, Ahmed S.</au><au>Hamdy, Abdallah M.</au><au>Salama, Fathy M.</au><au>Abdelkawy, Mohamed</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products</atitle><jtitle>Journal of chromatographic science</jtitle><addtitle>J Chromatogr Sci</addtitle><date>2016-10-01</date><risdate>2016</risdate><volume>54</volume><issue>9</issue><spage>1661</spage><epage>1669</epage><pages>1661-1669</pages><issn>0021-9665</issn><eissn>1945-239X</eissn><abstract>Two sensitive and accurate stability-indicating chromatographic methods were developed and validated for the determination of rafoxanide (RFX). Degradation products were identified by mass spectrometry and IR spectroscopy. The first is ultra-performance liquid chromatography method where separation was performed using acetonitrile:0.005 M potassium dihydrogen orthophosphate (pH 3.5) in a ratio of 80:20 by volume as a mobile phase using a Hypersil GOLD™ C8 column 1.9 mm (50 × 2.1 mm), UV detection was adjusted at 220 nm and the flow rate was 0.6 mL min−1. The other is a thin-layer chromatography-densitometry method where separation was achieved using a mobile phase composed of chloroform:ethyl acetate:toluene:ammonia (5:4:3:0.1 by volume) on silica gel 60 F254 plates, and densitometric detection was done at 280 nm. Validation was achieved as per the ICH guidelines. The proposed methods proved to be accurate, robust, specific and suitable for application as stability-indicating methods for routine analysis of RFX in quality control laboratories.</abstract><cop>United States</cop><pub>Oxford University Press</pub><pmid>27368343</pmid><doi>10.1093/chromsci/bmw112</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-9665
ispartof Journal of chromatographic science, 2016-10, Vol.54 (9), p.1661-1669
issn 0021-9665
1945-239X
language eng
recordid cdi_proquest_miscellaneous_1826714578
source Oxford University Press Journals All Titles (1996-Current); EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection; Free Full-Text Journals in Chemistry
title Validated UPLC and TLC-Densitometry Stability Indicating Methods for the Determination of Rafoxanide in the Presence of Its Degradation Products
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T09%3A18%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Validated%20UPLC%20and%20TLC-Densitometry%20Stability%20Indicating%20Methods%20for%20the%20Determination%20of%20Rafoxanide%20in%20the%20Presence%20of%20Its%20Degradation%20Products&rft.jtitle=Journal%20of%20chromatographic%20science&rft.au=Saad,%20Ahmed%20S.&rft.date=2016-10-01&rft.volume=54&rft.issue=9&rft.spage=1661&rft.epage=1669&rft.pages=1661-1669&rft.issn=0021-9665&rft.eissn=1945-239X&rft_id=info:doi/10.1093/chromsci/bmw112&rft_dat=%3Cproquest_cross%3E1826714578%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1826714578&rft_id=info:pmid/27368343&rft_oup_id=10.1093/chromsci/bmw112&rfr_iscdi=true