Fluoroscopic control allows for precise tunnel positioning in MPFL reconstruction

Purpose In MPFL reconstruction, anatomical graft positioning is required to restore physiological joint biomechanics and patellofemoral stability. Considerable rates of non-anatomical femoral tunnel placement exist. The purpose of this study was to analyse whether intraoperative fluoroscopic control...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA sports traumatology, arthroscopy : official journal of the ESSKA, 2017-09, Vol.25 (9), p.2688-2694
Hauptverfasser: Jaecker, Vera, Brozat, Benedikt, Banerjee, Marc, Otchwemah, Robin, Bouillon, Bertil, Shafizadeh, Sven
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose In MPFL reconstruction, anatomical graft positioning is required to restore physiological joint biomechanics and patellofemoral stability. Considerable rates of non-anatomical femoral tunnel placement exist. The purpose of this study was to analyse whether intraoperative fluoroscopic control is applicable to reduce variability of femoral tunnel positioning. Methods Femoral tunnel positions of 116 consecutive MPFL reconstructions applying intraoperative fluoroscopic images were analysed. Tunnel positions were determined by two independent observers according to Schöttle’s radiographic measurement method. Mean positions, standard deviations and ranges were calculated to determine the variability of the tunnel positions. Interclass correlation coefficient (ICC) was calculated. Results The mean anterior/posterior distances from the anatomical insertion of the MPFL to the centre of the femoral tunnel were 2.34 mm (range 0.0–5.9 mm) and 1.7 mm (range 0.1–7.3 mm, SD 1.3) for proximal/distal deviations; 95.7 % (111/116) of femoral tunnel positions were found to be within the anatomical insertion area defined by Schöttle. Interobserver tunnel position measurements were highly reliable (ICC: depth 0.979; height 0.979). Conclusion The study demonstrates that intraoperative fluoroscopic control is a feasible and effective method that enables to create reproducible and precise anatomical femoral tunnel positions in MPFL reconstruction. Accordingly, the routine use of intraoperative fluoroscopy can be recommended. Furthermore, the results indicate Schöttle’s method as a reliable method for intraoperative control and postoperative analysis of femoral tunnel positioning. Level of evidence IV.
ISSN:0942-2056
1433-7347
DOI:10.1007/s00167-015-3613-9